RecursosBibliotecas de símbolos DWG
Free AutoCAD civil site utility symbols (DWG): manholes, storm drains, water, gas, power, survey marks
Civil site utility plan: 222 blocos prontos de AutoCAD (DWG), de download gratuito e uso nos seus próprios projetos, em ZIP ou um símbolo por vez.
222 blocks at real size for site utility and drainage plans: manholes and chambers (storm, sanitary, combined, water, telecom, electric and gas, 900 to 2400 mm, rectangular chambers, drop, backdrop, shallow, terminal, existing and abandoned manholes, inspection chambers, rodding eyes, cleanouts, oil interceptors, grease and silt traps, wet wells and valve vaults); inlets, culverts and drainage structures (gullies, kerb and grate inlets, slotted and channel drains, headwalls, box and pipe culverts, flared ends, outfalls with flap valves, riprap, ditches, swales, soakaways, infiltration trenches, rain gardens, detention ponds and tanks, flow control and weir chambers); water supply and fire protection (hydrants, fire department connections, valves, meters, backflow preventers, tapping sleeves, thrust blocks, bends, tees, reducers, tanks, towers, pump stations, boreholes and wells); gas, power and telecom items (valves, meters, wood, concrete and steel poles, guy wires, transformers, switchgear, pull boxes, handholes, vaults, street lights, pedestals, cabinets, signal poles and masts); new, existing, abandoned and overhead pipe and cable lines with their codes, duct banks, casings and joint trenches; pipe trench, duct bank and manhole sections; kerbs, ramps, walls, fences, guard rails and steps; and civil tags and survey marks (structure and pipe tags, invert, spot elevation, benchmarks, control points, monuments, boundary marks, north arrow, flow and slope arrows, match line and section mark)
Usa o AutoCAD 2017 ou uma versão anterior? Baixar o formato 2010
Copyright CADXChange. Use e modifique os símbolos livremente nos seus desenhos e projetos, inclusive comerciais; crédito e link só são necessários se você os publicar. Não redistribua nem revenda a biblioteca. Cada ZIP contém um arquivo DWG simples no formato do AutoCAD 2018 e um README; não é preciso nenhum plug-in. Fornecido no estado em que se encontra, sem garantia. Termos da biblioteca (CXL-1.0)
Bibliotecas de símbolos relacionadas
Todos os 222 símbolos
222 de 222 símbolos
Storm manhole, 1050 dia
CIV_STM_MH_1050Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCStorm manhole, 1200 dia
CIV_STM_MH_1200Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCStorm manhole, 1500 dia
CIV_STM_MH_1500Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCStorm manhole, 1800 dia
CIV_STM_MH_1800Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCSanitary manhole, 1050 dia
CIV_SAN_MH_1050Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCSanitary manhole, 1200 dia
CIV_SAN_MH_1200Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCSanitary manhole, 1500 dia
CIV_SAN_MH_1500Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCSanitary manhole, 1800 dia
CIV_SAN_MH_1800Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCCombined manhole, 1050 dia
CIV_CMB_MH_1050Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCCombined manhole, 1200 dia
CIV_CMB_MH_1200Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCCombined manhole, 1500 dia
CIV_CMB_MH_1500Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCCombined manhole, 1800 dia
CIV_CMB_MH_1800Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCWater valve chamber, 1200 dia
CIV_WTR_CH_1200Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCWater valve chamber, 1800 dia
CIV_WTR_CH_1800Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCTelecom manhole, 900 dia
CIV_TEL_CH_900Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCTelecom manhole, 1200 dia
CIV_TEL_CH_1200Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCElectric manhole, 1200 dia
CIV_ELC_CH_1200Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCElectric manhole, 1800 dia
CIV_ELC_CH_1800Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCGas valve chamber, 1200 dia
CIV_GAS_CH_1200Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCChamber, rectangular, 900 x 900
CIV_RECT_CH_900X900Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCChamber, rectangular, 1200 x 1800
CIV_RECT_CH_1200X1800Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCChamber, rectangular, 1800 x 1800
CIV_RECT_CH_1800X1800Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCChamber, rectangular, 2400 x 2400
CIV_RECT_CH_2400X2400Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCDrop manhole, 1200 dia
CIV_MH_DROPAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCBackdrop manhole, 1500 dia
CIV_MH_BACKDROPAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCShallow manhole, 1050 dia
CIV_MH_SHALLOWAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCTerminal manhole, 1200 dia
CIV_MH_TERMINALAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCExisting manhole, 1200 dia
CIV_MH_EXISTINGAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCAbandoned manhole, 1200 dia
CIV_MH_ABANDONAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCInspection chamber, 450 dia
CIV_INSPECTIONAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCRodding eye
CIV_RODDING_EYEAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCCleanout, 150 dia
CIV_CLEANOUTAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCCleanout, two way
CIV_CLEANOUT_TWINAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCFlushing point
CIV_FLUSH_POINTAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCSampling chamber, 900 dia
CIV_SAMPLINGAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCOil interceptor, 1200 x 2400
CIV_OIL_INTERCEPTAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCGrease trap, 1200 x 1800
CIV_GREASE_TRAPAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCSilt trap, 1200 x 1200
CIV_SILT_TRAPAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCFlow meter chamber
CIV_FLOW_METER_CHAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCWet well, 2400 dia
CIV_WETWELL_2400Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCWet well, 3000 dia
CIV_WETWELL_3000Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCValve vault, 1800 x 2400
CIV_VALVE_VAULTAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCVent stack, 150 dia
CIV_VENT_STACKAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCGully, round, 300 dia
CIV_GULLY_300Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCGully, square, 450
CIV_GULLY_450Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCYard gully, 300 x 300
CIV_YARD_GULLYAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCKerb inlet, 1000
CIV_KERB_INLET_1000Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCKerb inlet, 1500
CIV_KERB_INLET_1500Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCKerb inlet, 2000
CIV_KERB_INLET_2000Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCGrate inlet, 600 x 600
CIV_GRATE_600Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCGrate inlet, 900 x 900
CIV_GRATE_900Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCGrate inlet, double, 600 x 1200
CIV_GRATE_DOUBLEAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCArea drain, round, 450
CIV_AREA_DRAINAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCSlotted drain, 3000
CIV_SLOT_DRAINAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCChannel drain, 3000
CIV_CHANNEL_3000Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCHeadwall, 450 pipe
CIV_HEADWALL_450Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCHeadwall, 900 pipe
CIV_HEADWALL_900Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCHeadwall, 1200 pipe
CIV_HEADWALL_1200Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCHeadwall, straight, 900 pipe
CIV_HEADWALL_STRAIGHTAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCBox culvert, 1800 x 1200
CIV_CULVERT_BOXAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCPipe culvert, 3000 run
CIV_CULVERT_PIPEAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCFlared end section
CIV_FLARED_ENDAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCOutfall with flap valve
CIV_OUTFALL_FLAPAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCRiprap apron, 3000 x 2000
CIV_RIPRAPAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCOpen ditch, 3000
CIV_DITCH_3000Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCGrass swale, 3000
CIV_SWALE_3000Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCSoakaway, 1500 dia
CIV_SOAKAWAY_1500Atributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCInfiltration trench, 3000
CIV_INFILTRATIONAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCRain garden, 3000 x 2000
CIV_RAIN_GARDENAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCDetention pond outline
CIV_POND_OUTLINEAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCUnderground tank, 3000 x 6000
CIV_TANK_UNDERAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCFlow control chamber
CIV_FLOW_CONTROLAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCWeir chamber, 1800 x 1200
CIV_WEIRAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCSump with pump
CIV_SUMP_PUMPAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCEnergy dissipator
CIV_ENERGY_DISSAtributos
TAGITEM_TYPESIZEMATERIALRIM_ELEV_MINVERT_ELEV_MDEPTH_MPIPE_SIZE_MMQTYMANUFACTURERMODELREMARKSDESCFire hydrant, pillar
CIV_HYDRANTAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCFire hydrant, two outlets
CIV_HYDRANT_PORTSAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCFire hydrant, flush
CIV_HYDRANT_FLUSHAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCFire hydrant, three outlets
CIV_HYDRANT_WYEAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCFire department connection
CIV_FDCAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCPost indicator valve
CIV_PIVAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCGate valve
CIV_GATE_VALVEAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCButterfly valve
CIV_BUTTERFLYAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCCheck valve
CIV_CHECK_VALVEAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCAir release valve
CIV_AIR_VALVEAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCPressure reducing valve
CIV_PRVAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCBlow-off valve
CIV_BLOWOFFAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCWater meter in chamber
CIV_METERAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCBackflow preventer
CIV_BACKFLOWAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCTapping sleeve and valve
CIV_TAPPINGAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCCorporation stop
CIV_CORP_STOPAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCCurb stop and box
CIV_CURB_STOPAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCWater service connection
CIV_SERVICE_STUBAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCThrust block, 90 bend
CIV_THRUST_BLOCKAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCBend, 90 degrees
CIV_BEND_90Atributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCBend, 45 degrees
CIV_BEND_45Atributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCBend, 22.5 degrees
CIV_BEND_22Atributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCTee
CIV_TEEAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCCross
CIV_CROSSAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCReducer
CIV_REDUCERAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCEnd cap
CIV_CAPAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCCoupling or sleeve
CIV_SLEEVEAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCStandpipe, 150 dia
CIV_STANDPIPEAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCBorehole, 300 dia
CIV_BOREHOLEAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCWater well, 900 dia
CIV_WELLAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCWater tank, 6000 dia
CIV_TANK_ELEVAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCElevated water tower
CIV_TOWERAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCWater pump station
CIV_PUMP_STATIONAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCPressure tank
CIV_PRESSURE_TANKAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCSpring box
CIV_SPRINGAtributos
TAGITEM_TYPESIZE_MMPRESSURE_RATINGMATERIALELEVATION_MQTYMANUFACTURERMODELREMARKSDESCGas pressure regulator
CIV_GAS_REGULATORAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCGas marker post
CIV_GAS_MARKERAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCUtility pole, wood
CIV_POLE_WOODAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCUtility pole, concrete
CIV_POLE_CONCRETEAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCUtility pole, steel
CIV_POLE_STEELAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCUtility pole with guy
CIV_POLE_GUYAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCGuy anchor
CIV_GUY_ANCHORAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCH-frame structure
CIV_POLE_HAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCPole mounted transformer
CIV_POLE_TRANSFORMERAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCPad mounted transformer
CIV_PAD_TRANSFORMERAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCGround mounted switchgear
CIV_SWITCHGEARAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCPull box, 450
CIV_PULLBOXAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCHandhole, 600 x 900
CIV_HANDHOLEAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCUtility vault, 1200 x 2400
CIV_VAULTAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCStreet light, single arm
CIV_LAMP_1Atributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCStreet light, double arm
CIV_LAMP_2Atributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCHigh mast light
CIV_LAMP_HIGHMASTAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCBollard light
CIV_BOLLARD_LIGHTAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCJunction cabinet
CIV_JUNCTION_CABAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCService pedestal
CIV_SERVICE_PEDAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCMeter pedestal
CIV_METER_PEDAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCTelecom pedestal
CIV_TELECOM_PEDAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCFibre handhole, 600 x 900
CIV_FIBRE_HHAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCFibre distribution cabinet
CIV_FDHAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCTraffic signal pole
CIV_SIGNAL_POLEAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCTraffic signal controller
CIV_SIGNAL_CABAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCAntenna mast
CIV_ANTENNA_MASTAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCSatellite dish, 2400 dia
CIV_DISHAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCCable marker post
CIV_MARKER_ELECAtributos
TAGITEM_TYPESIZEVOLTAGEOWNERHEIGHT_MQTYMANUFACTURERMODELREMARKSDESCStorm pipe, new
CIV_LINE_SD_NEWAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCSanitary sewer, new
CIV_LINE_SS_NEWAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCCombined sewer, new
CIV_LINE_CS_NEWAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCForce main, new
CIV_LINE_FM_NEWAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCReclaimed water main, new
CIV_LINE_RW_NEWAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCUnderground power, new
CIV_LINE_E_NEWAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCUnderground telecom, new
CIV_LINE_T_NEWAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCFibre optic cable, new
CIV_LINE_FO_NEWAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCStorm pipe, existing
CIV_LINE_SD_EXISTAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCSanitary sewer, existing
CIV_LINE_SS_EXISTAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCWater main, existing
CIV_LINE_W_EXISTAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCGas main, existing
CIV_LINE_G_EXISTAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCUnderground power, existing
CIV_LINE_E_EXISTAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCUnderground telecom, existing
CIV_LINE_T_EXISTAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCStorm pipe, abandoned
CIV_LINE_SD_ABANDAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCSanitary sewer, abandoned
CIV_LINE_SS_ABANDAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCWater main, abandoned
CIV_LINE_W_ABANDAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCGas main, abandoned
CIV_LINE_G_ABANDAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCOverhead power line
CIV_LINE_OHEAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCOverhead telecom line
CIV_LINE_OHTAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCSubsurface drain
CIV_LINE_SUBDRAINAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCPipe run with flow and slope
CIV_LINE_FLOWAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCPipe in casing, 3000
CIV_LINE_CASINGAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCDuct bank run, 3000
CIV_LINE_DUCTBANKAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCJoint utility trench, 3000
CIV_LINE_TRENCHAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCUtility crossing
CIV_LINE_CROSSINGAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCWarning tape, 3000
CIV_LINE_WARNINGAtributos
TAGITEM_TYPESIZE_MMMATERIALSLOPE_PCTLENGTH_MSTATUSREMARKSDESCPipe trench, 300 dia, granular
CIV_TRENCH_300Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCPipe trench, 450 dia, granular
CIV_TRENCH_450Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCPipe trench, 600 dia, granular
CIV_TRENCH_600Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCPipe trench, 900 dia, granular
CIV_TRENCH_900Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCPipe trench, 1200 dia, granular
CIV_TRENCH_1200Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCPipe trench, 300 dia, concrete
CIV_TRENCH_CONC_300Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCPipe trench, 600 dia, concrete
CIV_TRENCH_CONC_600Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCPipe trench, 900 dia, concrete
CIV_TRENCH_CONC_900Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCPipe in casing, section
CIV_CASING_SECTIONAtributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCManhole section, 1500 deep
CIV_MH_SECTION_1500Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCManhole section, 2500 deep
CIV_MH_SECTION_2500Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCManhole section, 3500 deep
CIV_MH_SECTION_3500Atributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESCKerb ramp with tactile paving
CIV_KERB_RAMPAtributos
TAGITEM_TYPESIZEMATERIALBEDDINGCOVER_MMREMARKSDESC
Faltou um símbolo? Diga qual.
Atributos para listas de materiais
Every block carries a tag you can number and invisible attributes for the schedule. A structure holds ITEM_TYPE, SIZE, MATERIAL, RIM_ELEV_M, INVERT_ELEV_M, DEPTH_M and PIPE_SIZE_MM; a water item holds SIZE_MM, PRESSURE_RATING, MATERIAL and ELEVATION_M; a power or telecom item holds SIZE, VOLTAGE, OWNER and HEIGHT_M; a line holds SIZE_MM, MATERIAL, SLOPE_PCT, LENGTH_M and STATUS (new, existing or abandoned); a section holds BEDDING and COVER_MM.
Export the blocks of a utility plan to Excel with BlockSync to list manholes with their rim and invert elevations, valves, hydrants and poles as a structure schedule, check the numbering and write the corrections back in one run, with preview and backup.
Como usar a biblioteca
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- The blocks are drawn at real size in millimetres, 1 drawing unit = 1 mm. If your site drawing is in metres, insert the blocks with a scale of 0.001 (or in millimetres at 1:1 on a sheet at the plot scale). A 1200 mm manhole is then 1.2 m on the plan, and a tag letter stays readable at 1:500.
- Round structures, poles and fittings are centred on their middle, so you snap them onto the pipe node. Line blocks lie along the x axis, centred, with a gap for the code (SD, SS, W, G, E, T) and are scaled to the length of the run; new lines are drawn in full weight, existing lines in a thin weight, abandoned lines dashed and crossed, overhead lines dashed with a dot at each end.
- Sections show a pipe trench with cover, bedding and optional concrete surround, duct banks, a pipe in casing and a precast manhole with cone, steps and base. They are details to put on a sheet next to the plan, not parts of the plan; the plan blocks and the section blocks use the same sizes.
About the drawings
There is no single standard for the drawings of site utility plans. The blocks follow the common practice of civil and utility drawings: a manhole as a circle with its code, a hydrant as a circle with FH, a valve as a bow tie, a pole as a circle with its material mark, lines with their service code in a break.
The blocks are our own drawings, not copies, and the library is not certified. The sizes are common precast and manufacturer sizes; pipe sizes, cover depths, separation distances, colour codes and structure details depend on your local authority and the utility owner, so use their standard drawings and check every part against the site survey.
Perguntas frequentes
- Can I use the blocks in a metre drawing?
- Yes. The blocks are in millimetres, so insert them with a scale of 0.001 (INSERT with scale factor 0.001) or set the block unit conversion; a 1200 mm manhole then measures 1.2 units on a drawing in metres. In a drawing in millimetres they come in at 1:1.
- Which structure sizes are included?
- Storm, sanitary and combined manholes at 1050, 1200, 1500 and 1800 mm, water, telecom, electric and gas chambers, rectangular chambers from 900 x 900 to 2400 x 2400, drop, backdrop, shallow and terminal manholes, inspection chambers, wet wells of 2400 and 3000 mm, and valve vaults, plus inlets, headwalls for 450, 900 and 1200 pipes and box and pipe culverts.
- Can I use the symbols in commercial projects?
- Yes. They are free to use and modify in your own projects, including commercial ones. They are provided as is, without warranty. Please do not redistribute or resell the library; see the library terms.
- How do I show existing and abandoned lines?
- Each utility has a new, an existing and (for storm, sanitary, water and gas) an abandoned line block. The existing line is drawn thin, the abandoned line is dashed and crossed, and the overhead lines are dashed with a dot at each end. The code in the break tells the service apart, so you can read the plan in black and white.
- Can I change a symbol or add attributes?
- Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
- Onde encontro um conjunto pronto destes símbolos para o AutoCAD?
- O AutoCAD traz só uns poucos blocos de exemplo, então um conjunto completo de símbolos precisa vir de uma biblioteca. Baixe o ZIP desta página e abra o DWG: cada símbolo é um bloco. Insira um com o comando INSERT (paleta Blocos, guia Bibliotecas, depois escolha o DWG) ou arraste-o do DesignCenter (ADCENTER). Também é possível baixar um símbolo isolado.