CADXChange

RecursosSímbolos de diagrama unifilar

110 kV substation fire protection system diagram: sample DWG with transformer deluge

The fire protection of a 110 kV substation drawn the way a power engineer reads it. On the left the fire water supply: two tanks, an electric, a diesel and a jockey pump and a pressure tank feed one fire water main. Two branches run to the two oil-filled transformers; each has an isolation valve, an electrically released deluge valve and a spray header around the transformer. Below each transformer the oil drain valve leads to an oil pit and on to a common oil-water separator, and a nitrogen injection cabinet sits between the two. Flame and heat detectors stand on the outer side of each transformer, a manual call point and a sounder sit on the same loop, and the fire alarm control panel, the release panel, the annunciator and the gateway to the substation control system are drawn in the top right corner. A legend of the four line types, the system data and notes complete the sheet, with a filled-in title block, on the same template as our process drawings.

Grátis para usar e modificar nos seus próprios projetos, inclusive comerciais. O ZIP traz o desenho de exemplo, um modelo, uma tabela de estilos de plotagem e um README; não precisa de nenhum add-in. Os dados do desenho são inventados, então ele não serve para projeto nem para obra. Fornecido como está, sem garantia. Termos da biblioteca (CXL-1.0)

Este exemplo usa estes recursos

Os símbolos são blocos das nossas próprias bibliotecas, com os atributos preenchidos. A folha e o carimbo vêm do nosso modelo de carimbo ISO A3. Baixe-os para desenhar os seus próprios esquemas.

O que vem no ZIP

  • Substation-Fire-Protection-System-Sample.dwg
    Desenho de exemplo (DWG, formato AutoCAD 2018)
  • Process-Template-ISO-A3.dwt
    Modelo (DWT) em que o desenho foi feito
  • CADXChange-Monochrome.ctb
    Tabela de estilos de plotagem (CTB) que imprime todas as cores em preto
  • README.txt
    README com a lista de layers e como usar os arquivos

O modelo

O modelo de processo tem 14 layers com cores, espessuras e tipos de linha (linhas principais, secundárias e de utilidades, sinais elétricos e pneumáticos, equipamentos, limites, setas de fluxo, tags, números de linha, texto e mais), os estilos de texto ISO-2.5 a ISO-5, o estilo de cota ISO-25 e um layout ISO A3 com carimbo e tabela de revisões. Os nomes dos layers seguem uma convenção comum, não uma norma; renomeie-os para combinar com as regras da sua empresa.

Layers definidos

Todos os layers do modelo com cor, espessura e tipo de linha, e quantos objetos deste exemplo estão em cada um. Os layers que o exemplo não usa continuam definidos, prontos para o seu desenho.

LayerCorEspessuraTipo de linhaUsoObjetos aqui
Layers de processo
PROC-PIPE-MAIN50.50 mmContinuousLinhas principais de processo27
PROC-PIPE-SEC40.35 mmContinuousLinhas de processo secundárias e derivações11
PROC-PIPE-UTIL300.35 mmContinuousLinhas de utilidades (vapor, condensado, água de resfriamento, ar)5
PROC-SIGNAL30.18 mmDASHEDLinhas de sinal elétrico28
PROC-PNEU60.18 mmDASHDOTLinhas de sinal pneumático e capilarnão usado aqui
SYMBOL70.25 mmContinuousSímbolos (o layer que as bibliotecas de símbolos usam)34
PROC-EQUIP70.35 mmContinuousContornos de equipamentos desenhados fora das bibliotecas de símbolosnão usado aqui
PROC-BOUNDARY10.18 mmDASHDOTLimites de pacote, skid e baterianão usado aqui
PROC-FLOW70.18 mmContinuousSetas de fluxo e marcas de sentido de fluxo1
PROC-TAG70.18 mmContinuousTags de equipamentos e instrumentosnão usado aqui
PROC-LINE-NO70.18 mmContinuousNúmeros de linha e especificações de linhanão usado aqui
PROC-TEXT70.18 mmContinuousTexto geral41
PROC-NOTES70.18 mmContinuousNotas e legendas14
PROC-DIM30.18 mmContinuousCotasnão usado aqui
Layers de folha e de símbolos
07padrãoContinuousLayer padrão, deixe vazionão usado aqui
FRAME7padrãoContinuousBorda da folha5
TITLEBLOCK7padrãoContinuousCarimbo e tabela de revisões1
VIEWPORT8padrãoContinuousMoldura da viewport do layout (não plota)2
DRAWING-AREA8padrãoContinuousLimite da área de desenho no modelo (não plota)2

Estilos definidos

Os estilos de texto, o estilo de cota e os tipos de linha que o modelo define, para você não precisar configurá-los em cada desenho novo.

TipoNomeConfigurações
Estilo de textoISOisocp.shx, 15°, altura variável
Estilo de textoISO-2.5isocp.shx, 15°, 2.5 mm de altura
Estilo de textoISO-3.5isocp.shx, 15°, 3.5 mm de altura
Estilo de textoISO-5isocp.shx, 15°, 5 mm de altura
Estilo de textoTB-enArial, usada pelo carimbo
Estilo de cotaISO-25Texto 2.5 mm, setas 2.5 mm, linhas de extensão 1.25 mm além da linha de cota e 0.625 mm do objeto, linhas de cota 3.75 mm entre si, 0 casas decimais
Tipo de linhaContinuousLinha contínua
Tipo de linhaDASHEDTracejada
Tipo de linhaDASHDOTTraço-ponto
Tipo de linhaCENTERLinha de centro
Tipo de linhaPHANTOMLinha fantasma
Tipo de linhaHIDDENLinha oculta

Configuração da folha e do desenho

Como a folha está configurada, para os seus desenhos serem impressos do mesmo jeito.

Folha
ISO A3 paisagem, 420 × 297 mm.
Layout
Um layout chamado ISO-A3, plotado em 1:1 em papel A3 sem margem, então a folha não tem margem de impressora.
Borda
20 mm da borda esquerda (lado da encadernação) e 10 mm das outras bordas; a área de desenho interna é de 390 × 277 mm.
Espaço modelo
As unidades são milímetros. A área de desenho aparece em 1:1, então 1 mm no desenho é 1 mm no papel.
Carimbo
160 × 79 mm no canto inferior direito, com uma tabela de revisões de quatro linhas acima dos campos de empresa, projeto, título e aprovação.
Tamanho do texto
2,5 mm para rótulos e notas, 3,5 mm e 5 mm para títulos.
Escala do tipo de linha
1, então os traços são dimensionados para plotar em 1:1.
Estilo de plotagem
Nenhum definido. Escolha o CTB do ZIP na configuração de página para plotagens em preto e branco.

Campos do carimbo

Os atributos do carimbo.

AtributoCampo na folhaValor neste exemplo
COMPANYCOMPANYCADXChange
PROJECTPROJECT110 kV Substation
AREAAREATransformer area
SYSTEMSYSTEMFire protection
CLIENTCLIENTSample
TITLEDRAWING TITLEFire protection system diagram
DRAWING_NODRAWING NO.F-501
CONTRACT_NOCONTRACT NO.—
REVREVA
DRAWNDRAWN—
CHECKEDCHECKED—
APPROVEDAPPROVED—
DATEDATE2026-11-25
SCALESCALENTS
SHEETSHEET1
SHEET_OFOF1

Tabela de revisões: R1 a R4, cada uma com REV, DATA, DESCRIÇÃO e POR (16 atributos, vazios neste exemplo).

Blocos no desenho

A lista de equipamentos do desenho: nome do bloco, símbolo e quantas vezes foi inserido.

SímboloBlocoInseridos
Sectional valve, OS&YPFP_VALVE_OSY3
Fire water tankPFP_FW_TANK2
Hydrant, pillarPFP_HYDRANT_PILLAR2
Deluge valve, electricPFP_DELUGE_ELEC2
Spray header, transformerPFP_SPRAY_HEADER2
Oil drain valvePFP_OIL_DRAIN_VALVE2
Transformer oil pitPFP_OIL_PIT2
Flame detector, UV/IRPFP_FLAME_UVIR2
Heat detector, fixedPFP_HEAT_FIXED2
Fire pump, electricPFP_PUMP_ELEC1
Fire pump, diesel enginePFP_PUMP_DIESEL1
Jockey pumpPFP_PUMP_JOCKEY1
Pressure tankPFP_PRESS_TANK1
Fire pump controllerPFP_PUMP_CTRL1
Oil-water separatorPFP_OIL_SEPARATOR1
Fire wall, transformersPFP_FIRE_WALL_TR1
Nitrogen injection cabinetPFP_N2_CABINET1
Fire alarm control panelPFP_FACP1
Releasing control panelPFP_RELEASE_PANEL1
Fire panel power supplyPFP_PSU1
Remote annunciatorPFP_ANNUNCIATOR1
Gateway to SCADAPFP_GATEWAY_SCADA1
Manual call pointPFP_MCP1
Horn and strobePFP_HORN_STROBE1

Lista de equipamentos

Uma linha por símbolo inserido, lida dos atributos dos blocos do desenho: o que aparece na folha e os atributos da lista que foram preenchidos mas não aparecem.

TagDescriçãoMostrado na folhaPreenchido, não mostrado
FWT-1Fire water tankPFP_FW_TANKVOLUME_M3 = 600MATERIAL = Reinforced concreteDESIGN_PRESSURE_BAR = 0SERVICE = Fire waterZONE = Pump houseLOCATION = Pump house yard
FWT-2Fire water tankPFP_FW_TANKVOLUME_M3 = 600MATERIAL = Reinforced concreteDESIGN_PRESSURE_BAR = 0SERVICE = Fire waterZONE = Pump houseLOCATION = Pump house yard
FP-1Fire pump, electricPFP_PUMP_ELECFLOW_M3H = 432HEAD_M = 92POWER_KW = 160PRESSURE_BAR = 9DRIVER = Electric motorZONE = Pump houseLOCATION = Pump house yard
FP-2Fire pump, diesel enginePFP_PUMP_DIESELFLOW_M3H = 432HEAD_M = 92POWER_KW = 170PRESSURE_BAR = 9DRIVER = Diesel engineZONE = Pump houseLOCATION = Pump house yard
JP-1Jockey pumpPFP_PUMP_JOCKEYFLOW_M3H = 18HEAD_M = 100POWER_KW = 3PRESSURE_BAR = 10DRIVER = Electric motorZONE = Pump houseLOCATION = Pump house yard
PT-1Pressure tankPFP_PRESS_TANKVOLUME_M3 = 0.5MATERIAL = Carbon steelDESIGN_PRESSURE_BAR = 12SERVICE = Fire water pressure keepingZONE = Transformer areaLOCATION = Transformer area
FPC-1Fire pump controllerPFP_PUMP_CTRLZONES = 3SUPPLY_V = 400 V ACCOMMUNICATION = Hardwired to FACP-1LOCATION = Pump house yard
V-1Sectional valve, OS&YPFP_VALVE_OSYSIZE_DN = 200PRESSURE_RATING = PN16ACTUATION = HandwheelSERVICE = Fire waterMATERIAL = Ductile ironSUPERVISED = YesZONE = Transformer area
HY-1Hydrant, pillarPFP_HYDRANT_PILLARSIZE_DN = 100OUTLETS = 2FLOW_LPS = 15PRESSURE_BAR = 4ZONE = Transformer areaLOCATION = Transformer area
HY-2Hydrant, pillarPFP_HYDRANT_PILLARSIZE_DN = 100OUTLETS = 2FLOW_LPS = 15PRESSURE_BAR = 4ZONE = Transformer areaLOCATION = Transformer area
V-2Sectional valve, OS&YPFP_VALVE_OSYSIZE_DN = 200PRESSURE_RATING = PN16ACTUATION = HandwheelSERVICE = Fire waterMATERIAL = Ductile ironSUPERVISED = YesZONE = Transformer area
DV-1Deluge valve, electricPFP_DELUGE_ELECSIZE_DN = 100RELEASE = Solenoid, 24 V DCPRESSURE_RATING = PN16TRIM = Electric release trimSUPERVISED = YesSERVICE = Transformer water sprayZONE = Transformer area
T1Spray header, transformerPFP_SPRAY_HEADERFLOW_LPM = 1530PRESSURE_BAR = 3.5K_FACTOR = 115ORIFICE_MM = 12SPRAY_ANGLE_DEG = 120MOUNTING = Ring pipe around the transformerZONE = Transformer area
OD-1Oil drain valvePFP_OIL_DRAIN_VALVESIZE_DN = 150PRESSURE_RATING = PN16ACTUATION = Electric actuatorSERVICE = Transformer oilMATERIAL = Carbon steelSUPERVISED = YesZONE = Transformer area
OP-1Transformer oil pitPFP_OIL_PITSERVICE = Oil containmentVOLUME_M3 = 40POWER_KW = -HAZARD = Transformer oilPROTECTION = Gravel bedZONE = Transformer areaLOCATION = Transformer area
FL-1Flame detector, UV/IRPFP_FLAME_UVIRDETECTOR_TYPE = UV/IR flameZONE = Transformer areaLOOP = 1ADDRESS = 1COVERAGE_M2 = 300MOUNTING = PoleRESPONSE = Under 5 sENCLOSURE = Explosion-proof
HD-1Heat detector, fixedPFP_HEAT_FIXEDDETECTOR_TYPE = Fixed temperature heatZONE = Transformer areaLOOP = 1ADDRESS = 1COVERAGE_M2 = 20MOUNTING = PoleRESPONSE = 93 CENCLOSURE = IP66
V-3Sectional valve, OS&YPFP_VALVE_OSYSIZE_DN = 200PRESSURE_RATING = PN16ACTUATION = HandwheelSERVICE = Fire waterMATERIAL = Ductile ironSUPERVISED = YesZONE = Transformer area
DV-2Deluge valve, electricPFP_DELUGE_ELECSIZE_DN = 100RELEASE = Solenoid, 24 V DCPRESSURE_RATING = PN16TRIM = Electric release trimSUPERVISED = YesSERVICE = Transformer water sprayZONE = Transformer area
T2Spray header, transformerPFP_SPRAY_HEADERFLOW_LPM = 1530PRESSURE_BAR = 3.5K_FACTOR = 115ORIFICE_MM = 12SPRAY_ANGLE_DEG = 120MOUNTING = Ring pipe around the transformerZONE = Transformer area
OD-2Oil drain valvePFP_OIL_DRAIN_VALVESIZE_DN = 150PRESSURE_RATING = PN16ACTUATION = Electric actuatorSERVICE = Transformer oilMATERIAL = Carbon steelSUPERVISED = YesZONE = Transformer area
OP-2Transformer oil pitPFP_OIL_PITSERVICE = Oil containmentVOLUME_M3 = 40POWER_KW = -HAZARD = Transformer oilPROTECTION = Gravel bedZONE = Transformer areaLOCATION = Transformer area
FL-2Flame detector, UV/IRPFP_FLAME_UVIRDETECTOR_TYPE = UV/IR flameZONE = Transformer areaLOOP = 1ADDRESS = 1COVERAGE_M2 = 300MOUNTING = PoleRESPONSE = Under 5 sENCLOSURE = Explosion-proof
HD-2Heat detector, fixedPFP_HEAT_FIXEDDETECTOR_TYPE = Fixed temperature heatZONE = Transformer areaLOOP = 1ADDRESS = 1COVERAGE_M2 = 20MOUNTING = PoleRESPONSE = 93 CENCLOSURE = IP66
OWS-1Oil-water separatorPFP_OIL_SEPARATORSERVICE = Oil and water separationVOLUME_M3 = 12POWER_KW = -HAZARD = Transformer oilPROTECTION = Overflow to drainZONE = Transformer areaLOCATION = Transformer area
FW-1Fire wall, transformersPFP_FIRE_WALL_TRRATING_H = 3MATERIAL = Reinforced concreteTHICKNESS_MM = 240TEST_STANDARD = Local codeLOCATION = Between T1 and T2ZONE = Transformer area
NC-1Nitrogen injection cabinetPFP_N2_CABINETSERVICE = Nitrogen injectionVOLUME_M3 = 0.4POWER_KW = -HAZARD = Transformer firePROTECTION = Oil drain and stirringZONE = Transformer areaLOCATION = Transformer area
FACP-1Fire alarm control panelPFP_FACPZONES = 8LOOPS = 2SUPPLY_V = 230 V AC, 24 V DCBATTERY_AH = 24COMMUNICATION = Serial link to gatewayLOCATION = Fire control roomADDRESS_RANGE = 1-250
RP-1Releasing control panelPFP_RELEASE_PANELZONES = 2LOOPS = 1SUPPLY_V = 24 V DCBATTERY_AH = 12COMMUNICATION = Hardwired to FACP-1LOCATION = Fire control roomADDRESS_RANGE = -
PSU-1Fire panel power supplyPFP_PSUSUPPLY_V = 230 V ACBATTERY_AH = 40LOCATION = Fire control room
ANN-1Remote annunciatorPFP_ANNUNCIATORZONES = 8SUPPLY_V = 24 V DCCOMMUNICATION = RS-485 from FACP-1LOCATION = Fire control room
GW-1Gateway to SCADAPFP_GATEWAY_SCADASUPPLY_V = 24 V DCCOMMUNICATION = IEC 60870-5-104LOCATION = Fire control room
MCP-1Manual call pointPFP_MCPTYPE = Break glass, weatherproofZONE = Transformer areaLOOP = 1ADDRESS = 150ENCLOSURE = IP66MOUNTING_HEIGHT_M = 1.4FUNCTION = Manual release of the deluge valves
HS-1Horn and strobePFP_HORN_STROBESOUND_DB = 100CANDELA = 75VOLTAGE_V = 24MOUNTING = PoleCIRCUIT = Sounder circuit 1ZONE = Transformer areaENCLOSURE = IP66

Fabricante, modelo e observações ficam vazios em todos os blocos, prontos para os seus dados. Os valores são exemplos.

Como usar

  1. Abra o desenho de exemplo para ver como layers, textos e o carimbo são usados, ou abra antes no navegador, sem instalar nada.
  2. Comece o seu desenho a partir do modelo (NOVO, depois escolha o arquivo DWT). Copie o arquivo CTB para a sua pasta de estilos de plotagem se quiser plotagens em preto e branco.
  3. Insira blocos da biblioteca de símbolos no seu desenho. Os blocos do exemplo são cópias; eles não mudam quando uma biblioteca muda.

Perguntas frequentes

Posso usar o desenho em um projeto real?
Como ponto de partida para a organização e os layers, sim. As potências, os ajustes e as bitolas de cabo são inventados, então o esquema precisa ser conferido e adaptado ao seu projeto antes de ser usado em projeto ou obra.
Por que os layers têm cores?
As cores e as espessuras seguem os layers: os circuitos de potência são vermelhos e grossos, o comando é ciano, o sinal é verde. A tabela de estilos de plotagem do ZIP imprime tudo em preto e mantém as espessuras, então também dá para plotar em preto e branco.
Quais programas de CAD abrem o arquivo?
O desenho e o modelo estão no formato do AutoCAD 2018, que o AutoCAD 2018 e posteriores abrem, assim como outros programas de CAD que leem esse formato. O visualizador no navegador não exige nenhuma instalação.