CADXChange

RecursosBibliotecas de símbolos DWG

Temas:Power system fire protection symbolsSímbolos de diagrama unifilarSímbolos de instalações prediais

AutoCAD power system fire protection symbols (DWG): fire water, spray, suppression, detection and alarm

Power system fire protection symbols: 256 blocos do AutoCAD prontos para usar (DWG). Um pacote inicial de 12 símbolos é grátis; a edição Padrão custa $79.

Pacote inicial grátis: 12 símbolos

Os símbolos mais usados desta biblioteca, como blocos do AutoCAD em um único DWG. Grátis para todos, para qualquer projeto.

  • Deluge valve setDeluge valve set
  • Water spray nozzleWater spray nozzle
  • Fire pump, electricFire pump, electric
  • Hydrant, pillarHydrant, pillar
  • Smoke detector, photoelectricSmoke detector, photoelectric
  • Linear heat cableLinear heat cable
  • Flame detector, UV/IRFlame detector, UV/IR
  • Fire alarm control panelFire alarm control panel
  • Penetration sealPenetration seal
  • Nitrogen injection cabinetNitrogen injection cabinet
  • Thermal runaway detectorThermal runaway detector
  • Battery containerBattery container

Pacote inicial grátis

$0

Para todos, para qualquer projeto

  • 12 símbolos
  • Sem login
  • Um único DWG

O que cada versão contém

Os símbolos por grupo, e quantos de cada grupo cada versão traz.

ConteúdoGrátisPadrão
Todos os símbolos12256
Acrescentado por esta versão—+244
Fire water supply222
Water spray and sprinklers230
Foam systems—8
Gas and aerosol systems—28
Transformer protection114
Detection328
Alarm and control122
Passive fire protection120
Mostrar mais 8 grupos
Cable facilities—8
Fire zones and hazard areas—10
Power plant areas—16
HVDC converter station—6
Battery energy storage220
Renewable and prefabricated—8
System diagram lines and marks—10
Extinguishers and fire points—6

O pacote grátis é uma seleção escolhida a dedo. O Padrão é uma compra única e entrega todos os símbolos em arquivos DWG.

256 symbols as ready-to-use AutoCAD blocks for the fire protection of power facilities: fire water supply (tanks, pumps with their drivers, hydrants, hose stations, monitors, valves); water spray, deluge, pre-action and sprinkler systems with electric, hydraulic and pneumatic release, spray rings and transformer headers, water mist; foam; clean agent, inert gas, CO2 and aerosol systems with cylinders, banks, selector valves, nozzles and release stations; transformer protection (oil pits, oil-water separators, accident sumps, nitrogen injection, fast drain and depressurisation, fire walls); detection (smoke, heat, linear heat, flame, beam, aspirating and gas detectors, manual call points); alarm panels, modules, notification appliances and gateways to DCS and SCADA; fire barriers, doors, dampers and penetration seals; cable spreading rooms, tunnels and trays; fire zones; power plant areas such as lube oil, hydrogen seal oil, coal handling and boiler front; HVDC valve halls; battery energy storage with thermal runaway and off-gas detection, deflagration vents and suppression; system diagram lines and extinguishers.

Versão 1.0 · atualizada em 25 de novembro de 2026 · Veja o que mudou

Todos os 256 símbolos

256 de 256 símbolos

Copyright CADXChange. Use e modifique os símbolos livremente nos seus desenhos e projetos, inclusive comerciais; crédito e link só são necessários se você os publicar. Não redistribua nem revenda a biblioteca. Cada ZIP contém um arquivo DWG simples no formato do AutoCAD 2018 e um README; não é preciso nenhum plug-in. Fornecido no estado em que se encontra, sem garantia. Termos da biblioteca (CXL-1.0)

Faltou um símbolo? Diga qual.

Atributos para listas de materiais

Every block has a visible tag next to the symbol (for example FP-1 for a pump, DV-1 for a deluge valve, SD-1 for a detector) and one visible rating. The data of your schedules are invisible attributes: ZONE, LOOP and ADDRESS for detectors and modules; FLOW_LPM, PRESSURE_BAR and K_FACTOR for nozzles; AGENT, FILL_KG and DISCHARGE_S for gas systems; RATING_H for barriers, dampers and seals; plus MANUFACTURER, MODEL and REMARKS on every block.

Como usar a biblioteca

  1. Unzip the file and open the DWG. Copy the symbols you need into your drawing, or drag the blocks in from DesignCenter (ADCENTER).
  2. The symbols are drawn at the plotted size in millimetres and have the size and style of the power system single-line library, so they can share a drawing with it. Insert them at scale 1 and scale the block if your drawing needs a different size.
  3. Valves, sprinklers, switches and pumps sit on a horizontal centre line with short stubs; detectors, panels and notification appliances are centred on their shape. Plan items such as rooms, pits, zones and cable facilities are pictograms: scale the inserted block to your drawing.
  4. Detectors use one hexagon with a letter and a subscript for the type, control units are boxes with their abbreviation, and extinguishing systems and extinguishers use the circle, square and triangle families. Change the letters in the block if your legend differs.

About the symbols

The figures of general fire protection equipment (sprinklers, valves, hydrants, extinguishers, detectors, control units, notification appliances and the extinguishing system marks) follow NFPA 170. Equipment specific to power facilities, such as transformer protection, cable facilities, converter stations, energy storage and plant areas, has no symbol standard: it is drawn after the protection requirements of NFPA 850 and NFPA 855 and the usual practice of the trade, with the same elements.

The blocks are our own drawings, not copies of a standard, and the library is not certified. Check them against the legend of your project, your client and the fire rules that apply, and change a block if yours differs.

O que mudou em cada versão

Versão 1.0 · 25 de novembro de 2026

Símbolos novos (256)

Fire water tank · Fire water reservoir · Fire pump, electric · Fire pump, diesel engine · Jockey pump · Fire pump set, packaged · Booster pump · Pressure tank · Fire water ring main · Sectional valve, OS&Y · Post indicator valve · Check valve, fire service · Butterfly valve, supervised · Hydrant, pillar · Hydrant, underground · Hydrant, wall · Hose station, wet standpipe · Fire monitor, fixed · Fire monitor, remote · Fire dept connection · Flow test header · Fire pump controller · Deluge valve set · Deluge valve, electric · Deluge valve, hydraulic · Deluge valve, pneumatic · Pre-action valve set · Dry pipe valve set · Wet alarm valve set · Foam-water deluge set · Water spray nozzle · Spray nozzle, high velocity · Spray nozzle, mid velocity · Projector nozzle · Spray ring, bushing · Spray header, transformer · Open sprinkler · Sprinkler, pendant · Sprinkler, upright · Sprinkler, sidewall · mais 216

Perguntas frequentes

Which fire protection standards does the library follow?
The general devices follow the figures of NFPA 170. The power-specific equipment has no symbol standard, so it is drawn after the protection requirements of NFPA 850 (power plants and HVDC converter stations) and NFPA 855 (energy storage) and the usual practice of the trade. It does not replace the fire rules of your project.
Does the library design the fire protection system?
No. It is a set of drawing symbols. The choice of agent, flow, coverage and detector layout comes from your engineering and the applicable code; the blocks carry attributes to record the result.
Can I use the symbols in commercial projects?
Yes, once you hold the licence. You may use and modify them in your own projects, including commercial ones. They are provided as is, without warranty. Please do not redistribute or resell the library; see the library terms.
What do I get free, and what is in the paid library?
A starter pack of 12 symbols and every single symbol preview are free to look at. The paid library has all the symbols in one DWG, one block per symbol, with a ZIP for AutoCAD 2018 and later and one for AutoCAD 2010.
Can I change a symbol or add attributes?
Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
Onde encontro um conjunto pronto destes símbolos para o AutoCAD?
O AutoCAD traz só uns poucos blocos de exemplo, então um conjunto completo de símbolos precisa vir de uma biblioteca. Baixe o ZIP desta página e abra o DWG: cada símbolo é um bloco. Insira um com o comando INSERT (paleta Blocos, guia Bibliotecas, depois escolha o DWG) ou arraste-o do DesignCenter (ADCENTER). Também é possível baixar um símbolo isolado.