RecursosBibliotecas de símbolos DWG
Free AutoCAD gas-insulated switchgear, alarm and installation symbols (DWG), IEC 60617 style
Gas-insulated switchgear, alarms and installation devices (IEC 60617): 108 ready-made AutoCAD blocks (DWG), free to download and use in your own projects, as a ZIP or one symbol at a time.
108 symbols as ready-to-use AutoCAD blocks, drawn after the newer figures of IEC 60617: gas-insulated switchgear (enclosures, compartment ends and partitions, bushings and sealing ends, support insulators, flanges, disconnectors with earthing switches), detectors and alarms (motion, smoke, flame and heat detectors in all variants, glass-break detector, smoke alarm, sounder, camera, emergency switch), installation switches (two-way, double, triple, dimmer, signal lamp, three-pole), network and data devices (router, hub, network switch, bus coupling unit, wireless link, sensor, transducer, transceiver), wiring marks (cable ladder, tray, channel, overhead line on pole, surface and concealed connections), bushing instrument transformers, phase shifters, selector switches, earthing and equipotential bonding, and the superconductivity symbols. Each block stores the database number of the standard in an invisible attribute.
Version 1.0 · updated 18 de outubro de 2026
Using AutoCAD 2017 or an earlier version? Download the 2010 format
Free to use and modify in your own projects, including commercial ones. The ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty.
IEC 60617 has several parts. The other libraries of the standard:
- Common electrical symbols (IEC 60617)
- Power system single-line symbols (IEC 60617)
- Electron tubes, crystals, delay lines (IEC 60617)
- Logic gate symbols (IEC 60617)
- Flip-flops, multiplexers, op amps (IEC 60617)
- Telephone, selectors, sound and recording (IEC 60617)
- Antennas, waveguides, modulation, filters and optical fibre (IEC 60617)
- Relays, protection and switching devices (IEC 60617)
- Machines, transformers, meters and symbol elements (IEC 60617)
- Busbar trunking, cable television, airfield lighting and connectors (IEC 60617)
Related symbol libraries
All 108 symbols
108 de 108 símbolos

GIS enclosure and conductor
GAI_S01391_GIS_ENCLOSURE_AND_CONDUCTORAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS compartment end, sealed
GAI_S01392_GIS_COMPARTMENT_END_SEALEDAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS compartment partition
GAI_S01393_GIS_COMPARTMENT_PARTITIONAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS partition, two chambers
GAI_S01459_GIS_PARTITION_TWO_CHAMBERSAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS gas through spacer
GAI_S01458_GIS_GAS_THROUGH_SPACERAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS support insul., inside
GAI_S01460_GIS_SUPPORT_INSUL_INSIDEAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS support insul., external
GAI_S01461_GIS_SUPPORT_INSUL_EXTERNALAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS conductor insulator
GAI_S01399_GIS_CONDUCTOR_INSULATORAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS flange, straight
GAI_S01400_GIS_FLANGE_STRAIGHTAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS to air-insulated bushing
GAI_S01396_GIS_TO_AIR_INSULATED_BUSHINGAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS to cable sealing end
GAI_S01397_GIS_TO_CABLE_SEALING_ENDAtributos
REMARKSSTD_CLAUSESTD_REFDESC
GIS to transformer bushing
GAI_S01398_GIS_TO_TRANSFORMER_BUSHINGAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Live connection terminal
GAI_S01836_LIVE_CONNECTION_TERMINALAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Disconnector, earth switch
GAI_S01848_DISCONNECTOR_EARTH_SWITCHAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Disconnecting breaker
GAI_S01859_DISCONNECTING_BREAKERAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Disconnecting breaker mark
GAI_S01860_DISCONNECTING_BREAKER_MARKAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Live connectable/disconnect.
GAI_S01849_LIVE_CONNECTABLE_DISCONNECTAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Simple voltage detector
GAI_S01843_SIMPLE_VOLTAGE_DETECTORAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Detector, general
GAI_S01870_DETECTOR_GENERALAtributos
REMARKSSTD_CLAUSESTD_REFDESC

Motion detector, infrared
GAI_S01872_MOTION_DETECTOR_INFRAREDAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Motion det., IR + ultrasonic
GAI_S01873_MOTION_DET_IR_ULTRASONICAtributos
REMARKSSTD_CLAUSESTD_REFDESC

Smoke detector, ionizing
GAI_S01875_SMOKE_DETECTOR_IONIZINGAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Smoke detector, optical
GAI_S01876_SMOKE_DETECTOR_OPTICALAtributos
REMARKSSTD_CLAUSESTD_REFDESC

Flame detector, ultraviolet
GAI_S01878_FLAME_DETECTOR_ULTRAVIOLETAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Flame detector, infrared
GAI_S01879_FLAME_DETECTOR_INFRAREDAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Flame det., UV and infrared
GAI_S01880_FLAME_DET_UV_AND_INFRAREDAtributos
REMARKSSTD_CLAUSESTD_REFDESC

Heat detector, maximum
GAI_S01883_HEAT_DETECTOR_MAXIMUMAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Heat detector, differential
GAI_S01884_HEAT_DETECTOR_DIFFERENTIALAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Heat det., max and diff.
GAI_S01885_HEAT_DET_MAX_AND_DIFFAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Heat, occurrence of
GAI_S01851_HEAT_OCCURRENCE_OFAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Smoke, occurrence of
GAI_S01852_SMOKE_OCCURRENCE_OFAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Flame, occurrence of
GAI_S01853_FLAME_OCCURRENCE_OFAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Motion, occurrence of
GAI_S01854_MOTION_OCCURRENCE_OFAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Glass break detector
GAI_S01445_GLASS_BREAK_DETECTORAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Smoke alarm device
GAI_S01902_SMOKE_ALARM_DEVICEAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Acoustic signalling device
GAI_S01417_ACOUSTIC_SIGNALLING_DEVICEAtributos
REMARKSSTD_CLAUSESTD_REFDESC

Push-button group unit
GAI_S01866_PUSH_BUTTON_GROUP_UNITAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Stand-alone emergency switch
GAI_S01864_STAND_ALONE_EMERGENCY_SWITCHAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Two-way switch, installation
GAI_S01900_TWO_WAY_SWITCH_INSTALLATIONAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Three-pole switch
GAI_S01899_THREE_POLE_SWITCHAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Double single-pole switch
GAI_S01905_DOUBLE_SINGLE_POLE_SWITCHAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Triple on-off switch
GAI_S01906_TRIPLE_ON_OFF_SWITCHAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Triple single-pole switch
GAI_S01909_TRIPLE_SINGLE_POLE_SWITCHAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Triple two-way switch
GAI_S01901_TRIPLE_TWO_WAY_SWITCHAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Double two-way switch
GAI_S01867_DOUBLE_TWO_WAY_SWITCHAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Two-way and on-off switch
GAI_S01868_TWO_WAY_AND_ON_OFF_SWITCHAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Two-way switch with dimmer
GAI_S01869_TWO_WAY_SWITCH_WITH_DIMMERAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Switch with signal lamp
GAI_S01907_SWITCH_WITH_SIGNAL_LAMPAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Fluorescent lamp, general
GAI_S01886_FLUORESCENT_LAMP_GENERALAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Socket, 3-phase and 1-phase
GAI_S01897_SOCKET_3_PHASE_AND_1_PHASEAtributos
REMARKSSTD_CLAUSESTD_REFDESC



Bus coupling unit
GAI_S01898_BUS_COUPLING_UNITAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Wireless connection
GAI_S01863_WIRELESS_CONNECTIONAtributos
REMARKSSTD_CLAUSESTD_REFDESC



Amplification, general
GAI_S01457_AMPLIFICATION_GENERALAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Complex switch, general
GAI_S01454_COMPLEX_SWITCH_GENERALAtributos
REMARKSSTD_CLAUSESTD_REFDESC

Concentric conductor
GAI_S01807_CONCENTRIC_CONDUCTORAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Connection on cable ladder
GAI_S01449_CONNECTION_ON_CABLE_LADDERAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Connection in cable tray
GAI_S01450_CONNECTION_IN_CABLE_TRAYAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Connection in wall channel
GAI_S01451_CONNECTION_IN_WALL_CHANNELAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Overhead line, pole, strut
GAI_S01452_OVERHEAD_LINE_POLE_STRUTAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Overhead line, pole and stay
GAI_S01453_OVERHEAD_LINE_POLE_AND_STAYAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Connection, behind surface
GAI_S01916_CONNECTION_BEHIND_SURFACEAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Connection, surface mounted
GAI_S01917_CONNECTION_SURFACE_MOUNTEDAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Directed connection
GAI_S01414_DIRECTED_CONNECTIONAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Point of access to a bundle
GAI_S01415_POINT_OF_ACCESS_TO_A_BUNDLEAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Phase shifter, three-phase
GAI_S01837_PHASE_SHIFTER_THREE_PHASEAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Phase shifter, 3-ph, wound
GAI_S01838_PHASE_SHIFTER_3_PH_WOUNDAtributos
REMARKSSTD_CLAUSESTD_REFDESC

Bushing VT, single-pole
GAI_S01839_BUSHING_VT_SINGLE_POLEAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Bushing VT, two winding
GAI_S01840_BUSHING_VT_TWO_WINDINGAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Bushing CT, single-pole
GAI_S01841_BUSHING_CT_SINGLE_POLEAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Bushing CT, wound
GAI_S01842_BUSHING_CT_WOUNDAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Voltage selector switch, 1
GAI_S01855_VOLTAGE_SELECTOR_SWITCH_1Atributos
REMARKSSTD_CLAUSESTD_REFDESC
Current selector switch, 1
GAI_S01856_CURRENT_SELECTOR_SWITCH_1Atributos
REMARKSSTD_CLAUSESTD_REFDESC
Current selector, with N
GAI_S01857_CURRENT_SELECTOR_WITH_NAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Voltage selector, 6 readings
GAI_S01858_VOLTAGE_SELECTOR_6_READINGSAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Autotransformer, tertiary
GAI_S01913_AUTOTRANSFORMER_TERTIARYAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Autotransformer, tertiary 2
GAI_S01914_AUTOTRANSFORMER_TERTIARY_2Atributos
REMARKSSTD_CLAUSESTD_REFDESC
Functional earth (earth bar)
GAI_S01408_FUNCTIONAL_EARTH_EARTH_BARAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Functional equipotential 1
GAI_S01409_FUNCTIONAL_EQUIPOTENTIAL_1Atributos
REMARKSSTD_CLAUSESTD_REFDESC
Functional equipotential 2
GAI_S01410_FUNCTIONAL_EQUIPOTENTIAL_2Atributos
REMARKSSTD_CLAUSESTD_REFDESC
Conversion, separated
GAI_S01407_CONVERSION_SEPARATEDAtributos
REMARKSSTD_CLAUSESTD_REFDESC

CHP station, planned
GAI_S01419_CHP_STATION_PLANNEDAtributos
REMARKSSTD_CLAUSESTD_REFDESC
CHP station, in service
GAI_S01420_CHP_STATION_IN_SERVICEAtributos
REMARKSSTD_CLAUSESTD_REFDESC


DC supply function
GAI_S01423_DC_SUPPLY_FUNCTIONAtributos
REMARKSSTD_CLAUSESTD_REFDESC

Mechanically lockable
GAI_S01918_MECHANICALLY_LOCKABLEAtributos
REMARKSSTD_CLAUSESTD_REFDESC

Multiple-function switching
GAI_S01413_MULTIPLE_FUNCTION_SWITCHINGAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Break contact, manual
GAI_S01912_BREAK_CONTACT_MANUALAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Break contact, delayed
GAI_S01911_BREAK_CONTACT_DELAYEDAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Superconducting connection
GAI_S01924_SUPERCONDUCTING_CONNECTIONAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Normal-superconducting joint
GAI_S01925_NORMAL_SUPERCONDUCTING_JOINTAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Josephson junction
GAI_S01926_JOSEPHSON_JUNCTIONAtributos
REMARKSSTD_CLAUSESTD_REFDESC
Faltou um símbolo? Diga qual.
Attributes for parts lists
The blocks carry no visible tag. Invisible attributes: REMARKS, STD_CLAUSE and STD_REF (the database number).
Because the data sit in attributes, you can export the devices of a project to Excel with BlockSync, build a list, check it and write the corrections back in one run, with preview and backup.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- The symbols are drawn at plotted size in millimetres on a 2.5 mm grid, the grid of the standard's pages: a boxed device is about 10 to 20 mm wide, a contact about 15 mm high. Insert them at the scale of your drawing, for example scale 2 on a 1:2 drawing.
- The gas-insulated switchgear symbols are fragments: the enclosure lines and the conductor run horizontally and the mark sits in the middle, so place them on a drawn run and trim the lines. Detectors are boxes with the symbol in the upper field and a letter code (IR, UV, Max, Dif) in the lower field. Switches and sockets are centred on their circle; the contact strokes show the poles.
- Variants share the same body and differ by a mark or a detail. Edit the mark to make a variant that is not in the library.
About IEC 60617
IEC 60617 is the international standard for graphical symbols for diagrams, in many parts. This library holds figures from the standard's database that carry no part number, are new in the current edition and are missing from the other IEC 60617 libraries of this site, drawn after the database.
These symbols are our own drawings after the figures of the standard. They are not copied from it, and the library is not certified against it. Check them against the standard, your company standard or your customer’s legend before you decide to use a symbol.
Frequently asked questions
- Where are the common switches, sockets and luminaires?
- Ordinary switches, push-buttons, sockets and lighting outlets of installation diagrams are in the library “Common electrical symbols (IEC 60617)”. This library adds the newer ones: multi-gang and dimmer switches, single-phase and three-phase sockets, detectors, alarms and network devices.
- Where are the other IEC 60617 symbols?
- The standard is spread over several libraries on this site: common electrical symbols, power system single-line, semiconductors and tubes, binary logic elements, logic functions and analogue, telephone and sound, telecom transmission, relays and protection, machines and meters, and busbar trunking with cable television. Every library page lists the others.
- Can I use the symbols in commercial projects?
- Yes. They are free to use and modify in your own projects, including commercial ones. They are provided as is, without warranty.
- Do the gas-insulated switchgear symbols include the enclosure lines?
- Yes. The standard shows them as context lines; each block draws the enclosure and the conductor as plain lines of one length, so the symbol reads on its own. Trim or extend them to your run.
- Can I change a symbol or add attributes?
- Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
- Where do I find a ready-made set of these symbols for AutoCAD?
- AutoCAD itself ships only a small set of sample blocks, so a full symbol set has to come from a library. Download the ZIP on this page and open the DWG: every symbol is a block. Insert one with INSERT (Blocks palette, Libraries tab, then pick the DWG) or drag it from DesignCenter (ADCENTER). You can also download a single symbol on its own.
Count the symbols and build a parts list
Because ratings and part numbers are attributes, the symbols of a whole project can be counted and listed without opening the drawings. Export the blocks to Excel, total them with a pivot table and write corrections back in one run, with preview and backup.
See how to count blocks with BlockSync