KaynaklarElektrik şeması sembolleri
Control panel layout drawing: sample DWG of a pump control panel with door view and mounting plate
A panel builder's drawing, not a circuit diagram: where every device sits. The door view at 1:5 shows the HMI, selector switches, pilot lights, emergency stop, main switch handle and the fan and exhaust filters. The mounting plate at 1:5 is laid out in the usual door shape: plain wire ducts along the top and both sides with two cross ducts, 30 mm clear of the devices, carrying the isolator and breakers, the power supply, the PLC with its I/O modules, two motor starters and the terminal strips, with the row pitch dimensioned. Rails and drilling are left out, as in a layout drawing (the plate cut-out has its own drawing). Beside them are the device list, the terminal assignment and a heat loss table with the air flow check for the fan.
Free to use and modify in your own projects, including commercial ones. The ZIP holds the sample drawing, a template, a plot style table and a README; no add-in needed. The data in the drawing is made up, so it is not for design or construction. Provided as is, without warranty.
This sample uses these resources
The symbols are blocks from our own libraries, with their attributes filled in. The sheet and its title block come from our ISO A3 title block template. Download them to draw your own diagrams.
What is in the ZIP
- Pump-Control-Panel-Layout-Sample.dwg
Sample drawing (DWG, AutoCAD 2018 format) - Electrical-Template-ISO-A3.dwt
Template (DWT) that the drawing was made on - CADXChange-Monochrome.ctb
Plot style table (CTB) that prints every colour black - README.txt
README with the layer list and how to use the files
The template
The electrical template has 16 layers with colours, line weights and linetypes (power circuits, busbars, control, signal, protective earth, enclosure boundaries, text and more), the text styles ISO-2.5 to ISO-5, the dimension style ISO-25 and an ISO A3 layout with a title block and revision table. The layer names are a common convention, not a standard; rename them to match your company's rules.
Layers defined
Every layer in the template with its colour, line weight and linetype, and how many objects of this sample are on it. Layers the sample does not use are still defined, ready for your own drawing.
| Layer | Colour | Line weight | Linetype | Used for | Objects here |
|---|---|---|---|---|---|
| Electrical layers | |||||
| ELEC-POWER | 1 | 0.50 mm | Continuous | Main power circuits | not used here |
| ELEC-BUS | 1 | 0.70 mm | Continuous | Busbars and heavy lines | not used here |
| ELEC-CONTROL | 4 | 0.25 mm | Continuous | Control circuits | not used here |
| ELEC-SIGNAL | 3 | 0.18 mm | Continuous | Signal, instrumentation and communication circuits | not used here |
| ELEC-PE | 2 | 0.35 mm | Continuous | Protective earth and bonding | not used here |
| ELEC-CABLE | 30 | 0.25 mm | DASHED | Cable, conduit and tray routes | not used here |
| SYMBOL | 7 | 0.25 mm | Continuous | Symbols (the layer the symbol libraries use) | 34 |
| ELEC-TERMINAL | 7 | 0.25 mm | Continuous | Terminals and connection points | 10 |
| ELEC-BOUNDARY | 5 | 0.18 mm | DASHDOT | Enclosure, panel and device boundaries | not used here |
| ELEC-MECH-LINK | 8 | 0.18 mm | DASHED | Mechanical links, interlocks and measuring links | not used here |
| ELEC-REF | 7 | 0.18 mm | Continuous | Reference designations (-QF1, -K2) | not used here |
| ELEC-WIRE-NO | 7 | 0.18 mm | Continuous | Wire numbers and cable labels | not used here |
| ELEC-XREF | 9 | 0.13 mm | Continuous | Contact and cross reference texts | not used here |
| ELEC-TEXT | 7 | 0.18 mm | Continuous | General text | 200 |
| ELEC-NOTES | 7 | 0.18 mm | Continuous | Notes and legends | 6 |
| ELEC-DIM | 3 | 0.18 mm | Continuous | Dimensions | 8 |
| Sheet and symbol layers | |||||
| 0 | 7 | default | Continuous | Default layer, keep it empty | not used here |
| FRAME | 7 | default | Continuous | Sheet border | 5 |
| TITLEBLOCK | 7 | default | Continuous | Title block and revision table | 1 |
| VIEWPORT | 8 | default | Continuous | Layout viewport frame (does not plot) | 2 |
| DRAWING-AREA | 8 | default | Continuous | Boundary of the model drawing area (does not plot) | 2 |
Styles defined
The text styles, the dimension style and the linetypes that the template defines, so you do not have to set them up in each new drawing.
| Kind | Name | Settings |
|---|---|---|
| Text style | ISO | isocp.shx, 15°, variable height |
| Text style | ISO-2.5 | isocp.shx, 15°, 2.5 mm high |
| Text style | ISO-3.5 | isocp.shx, 15°, 3.5 mm high |
| Text style | ISO-5 | isocp.shx, 15°, 5 mm high |
| Text style | TB-en | Arial, used by the title block |
| Dimension style | ISO-25 | Text 2.5 mm, arrows 2.5 mm, extension lines 1.25 mm beyond the dimension line and 0.625 mm from the object, dimension lines 3.75 mm apart, 0 decimals |
| Linetype | Continuous | Solid line |
| Linetype | DASHED | Dashed |
| Linetype | DASHDOT | Dash-dot |
| Linetype | CENTER | Centre line |
| Linetype | PHANTOM | Phantom line |
| Linetype | HIDDEN | Hidden line |
Sheet and drawing setup
How the sheet is set up, so your own drawings print the same way.
- Sheet
- ISO A3 landscape, 420 × 297 mm.
- Layout
- One layout named ISO-A3, plotted at 1:1 on full-bleed A3 media, so the sheet has no printer margin.
- Border
- 20 mm from the left edge (binding side) and 10 mm from the other edges; the drawing area inside is 390 × 277 mm.
- Model space
- Units are millimetres. The drawing area is shown at 1:1, so 1 mm in the drawing is 1 mm on paper.
- Title block
- 160 × 79 mm at the lower right, with a four-line revision table above the company, project, title and approval fields.
- Text size
- 2.5 mm for labels and notes, 3.5 mm and 5 mm for headings.
- Linetype scale
- 1, so dashes are sized for plotting at 1:1.
- Plot style
- None set. Pick the CTB from the ZIP in the page setup for black-and-white plots.
Title block fields
The attributes of the title block. Double-click it to fill them in, or write them for a whole set of drawings with BlockSync.
| Attribute | Field on the sheet | Value in this sample |
|---|---|---|
| COMPANY | COMPANY | CADXChange |
| PROJECT | PROJECT | Booster Pump Station |
| AREA | AREA | Pump room |
| SYSTEM | SYSTEM | 400 V AC / 24 V DC |
| CLIENT | CLIENT | Sample |
| TITLE | DRAWING TITLE | Pump control panel, layout |
| DRAWING_NO | DRAWING NO. | E-401 |
| CONTRACT_NO | CONTRACT NO. | — |
| REV | REV | A |
| DRAWN | DRAWN | — |
| CHECKED | CHECKED | — |
| APPROVED | APPROVED | — |
| DATE | DATE | 2026-10-21 |
| SCALE | SCALE | 1:5 |
| SHEET | SHEET | 1 |
| SHEET_OF | OF | 1 |
Revision table: R1 to R4, each with REV, DATE, DESCRIPTION and BY (16 attributes, empty in this sample).
Blocks in the drawing
The equipment list of the drawing: block name, symbol and how many times it is placed. BlockSync exports the same list from your own drawings.
| Symbol | Block | Placed |
|---|---|---|
| CPL_PILOT_LIGHT | 3 | |
| CPL_SELECTOR_3 | 2 | |
| CPL_MCB_1P | 2 | |
| CPL_RELAY_SLIM_14 | 2 | |
| CPL_MPCB_45 | 2 | |
| CPL_CONTACTOR_9A | 2 | |
| CPL_ENC_600X800 | 1 | |
| CPL_HMI_7 | 1 | |
| CPL_EXHAUST_FILTER_120 | 1 | |
| CPL_PB_BLUE | 1 | |
| CPL_ESTOP_PLATE | 1 | |
| CPL_MAIN_SWITCH | 1 | |
| CPL_PLATE_LABEL | 1 | |
| CPL_FAN_FILTER_120 | 1 | |
| CPL_ISOLATOR_3P | 1 | |
| CPL_RCBO_2M | 1 | |
| CPL_THERMOSTAT | 1 | |
| CPL_SOCKET_SERVICE | 1 | |
| CPL_PSU_24V_5A | 1 | |
| CPL_PLC_CPU_S | 1 | |
| CPL_IO_DI16 | 1 | |
| CPL_IO_DO16 | 1 | |
| CPL_IO_AI8 | 1 | |
| CPL_SWITCH_ETH_5 | 1 | |
| CPL_TERM_RUN_20 | 1 | |
| CPL_TERM_RUN_10 | 1 | |
| CPL_PE_BAR_300 | 1 |
Equipment schedule
One row per placed symbol, read from the attributes of the blocks in the drawing: what is shown on the sheet, and the schedule attributes that were filled in but are not shown. BlockSync exports these same attributes from your own drawings.
| Tag | Description | Shown on the sheet | Filled in, not shown |
|---|---|---|---|
| A0 | Wall enclosure 600 x 800CPL_ENC_600X800 | SIZE = 600 x 800DEPTH_MM = 250MATERIAL = Sheet steel, RAL 7035IP_RATING = IP54QTY = 1 | |
| A6 | HMI panel 7-inch, cutoutCPL_HMI_7 | CUTOUT_MM = 200 x 140DIAGONAL = 7 inQTY = 1 | |
| E5 | Exhaust filter 120 mmCPL_EXHAUST_FILTER_120 | CUTOUT_MM = 120 x 120QTY = 1 | |
| S2 | Selector switch, 3 positionCPL_SELECTOR_3 | CONTACTS = 1 NO + 1 NOPOSITIONS = Hand - 0 - AutoQTY = 1 | |
| S3 | Selector switch, 3 positionCPL_SELECTOR_3 | CONTACTS = 1 NO + 1 NOPOSITIONS = Hand - 0 - AutoQTY = 1 | |
| H1 | Pilot light, 22 mmCPL_PILOT_LIGHT | COLOUR = GreenLAMP_V = 24 V DCQTY = 1 | |
| H2 | Pilot light, 22 mmCPL_PILOT_LIGHT | COLOUR = GreenLAMP_V = 24 V DCQTY = 1 | |
| H3 | Pilot light, 22 mmCPL_PILOT_LIGHT | COLOUR = RedLAMP_V = 24 V DCQTY = 1 | |
| S4 | Pushbutton, flush, blueCPL_PB_BLUE | CONTACTS = 1 NOCIRCUIT = Fault resetQTY = 1 | |
| S1 | Emergency stop with yellow collar plateCPL_ESTOP_PLATE | CONTACTS = 2 NCQTY = 1 | |
| Q0 | Main switch, door-coupled rotaryCPL_MAIN_SWITCH | RATING = 32 APOLES = 3QTY = 1 | |
| E4 | Fan and filter unit 120 mmCPL_FAN_FILTER_120 | AIRFLOW_M3H = 55CUTOUT_MM = 120 x 120VOLTAGE = 230 V ACQTY = 1 | |
| Q0 | Isolator switch on rail, 3 poleCPL_ISOLATOR_3P | RATING = 32 APOLES = 3QTY = 1 | |
| F1 | Miniature circuit breaker, 1 poleCPL_MCB_1P | RATING = C 4 ACHARACTERISTIC = CPOLES = 1QTY = 1 | |
| F2 | RCBO 1P+N, 2 modulesCPL_RCBO_2M | RATING = B 10 ACHARACTERISTIC = BRESIDUAL_MA = 30CIRCUIT = Service socketQTY = 1 | |
| F3 | Miniature circuit breaker, 1 poleCPL_MCB_1P | RATING = C 4 ACHARACTERISTIC = CPOLES = 1CIRCUIT = Fan circuitQTY = 1 | |
| B1 | Enclosure thermostatCPL_THERMOSTAT | SETPOINT_C = 35QTY = 1 | |
| X3 | Service socket, rail mountedCPL_SOCKET_SERVICE | RATING = 10 A 230 VQTY = 1 | |
| G1 | Power supply 24 V DC, 5 ACPL_PSU_24V_5A | OUTPUT_V = 24 V DCOUTPUT_A = 5 AINPUT = 230 V ACQTY = 1 | |
| A1 | PLC CPU module, smallCPL_PLC_CPU_S | CPU_TYPE = CompactMEMORY = 256 KBQTY = 1 | |
| A2 | Digital input module, 16 channelsCPL_IO_DI16 | CHANNELS = 16VOLTAGE = 24 V DCADDRESS = I0.0-I1.7QTY = 1 | |
| A3 | Digital output module, 16 channelsCPL_IO_DO16 | CHANNELS = 16VOLTAGE = 24 V DC 0.5 AADDRESS = Q0.0-Q1.7QTY = 1 | |
| A4 | Analog input module, 8 channelsCPL_IO_AI8 | CHANNELS = 8VOLTAGE = 4-20 mAADDRESS = IW64-IW78QTY = 1 | |
| A5 | Ethernet switch, 5 port, unmanagedCPL_SWITCH_ETH_5 | PORTS = 5QTY = 1 | |
| K3 | Interface relay, 14 mmCPL_RELAY_SLIM_14 | VOLTAGE = 24 V DCCONTACTS = 1 COQTY = 1 | |
| K4 | Interface relay, 14 mmCPL_RELAY_SLIM_14 | VOLTAGE = 24 V DCCONTACTS = 1 COQTY = 1 | |
| Q1 | Motor protection circuit breakerCPL_MPCB_45 | RATING = 6.3-10 ASETTING_A = 8.5CIRCUIT = Pump 1QTY = 1 | |
| K1 | Contactor 9 A, 3 poleCPL_CONTACTOR_9A | RATING = 9 A AC-3COIL_V = 24 V DCCIRCUIT = Pump 1QTY = 1 | |
| Q2 | Motor protection circuit breakerCPL_MPCB_45 | RATING = 6.3-10 ASETTING_A = 8.5CIRCUIT = Pump 2QTY = 1 | |
| K2 | Contactor 9 A, 3 poleCPL_CONTACTOR_9A | RATING = 9 A AC-3COIL_V = 24 V DCCIRCUIT = Pump 2QTY = 1 | |
| X1 | Terminal strip, 20 terminals, 6.2 mmCPL_TERM_RUN_20 | TERMINALS = 20CROSS_SECTION = 4 mm2QTY = 1 | |
| X2 | Terminal strip, 10 terminals, 6.2 mmCPL_TERM_RUN_10 | TERMINALS = 10CROSS_SECTION = 2.5 mm2QTY = 1 | |
| PE | PE busbar, 300 mmCPL_PE_BAR_300 | LENGTH_MM = 300QTY = 1 |
Manufacturer, model and remarks are left empty on every block, ready for your data. The values are examples.
How to use it
- Open the sample drawing to see how layers, text and the title block are used, or open it in the browser first, nothing to install.
- Start your own drawing from the template (NEW, then pick the DWT file). Copy the CTB file to your plot styles folder if you want black-and-white plots.
- Insert blocks from the symbol library into your drawing. The blocks in the sample are copies; they do not change when a library changes.
- Double-click the title block to fill it in, then export the equipment list with BlockSync.
Frequently asked questions
- Can I use the drawing for a real project?
- As a starting point for layout and layers, yes. The ratings, settings and cable sizes are made up, so the diagram has to be checked and changed for your project before it is used for design or construction.
- Why are the layers coloured?
- Colours and line weights follow the layers: power circuits are red and heavy, control is cyan, signal is green. The plot style table in the ZIP prints everything black and keeps the line weights, so you can plot in black and white as well.
- Which CAD programs open it?
- The drawing and the template are in AutoCAD 2018 format, which AutoCAD 2018 and later open, and so do other CAD programs that read this format. The browser viewer needs nothing installed.