CADXChange

KaynaklarPower system primary equipment symbols

110 kV GIS substation single-line diagram: sample DWG with a double busbar

A 110 kV gas-insulated substation drawn the way a power engineer reads it. Two busbars run across the sheet; every bay hangs from them through a pair of busbar disconnectors, so it can be fed from either bus. The line bays and the transformer bays each have a breaker, a current transformer, a line disconnector, a fast earthing switch and a surge arrester; the line bays leave through an air bushing, the transformer bays through a cable termination to a 63 MVA transformer. A bus coupler ties the two busbars and two voltage transformer bays sit on the ends. The sheet carries an equipment list, a bay schedule and a filled-in title block, on the same electrical template as our other power drawings.

Kendi projelerinizde, ticari olanlar dahil, ücretsiz kullanabilir ve değiştirebilirsiniz. ZIP içinde örnek çizim, bir şablon, bir plot stili tablosu ve bir README bulunur; eklenti gerekmez. Çizimdeki veriler uydurmadır, bu yüzden tasarım ya da inşaat için kullanılamaz. Olduğu gibi sunulur, garanti verilmez. Kütüphane koşulları (CXL-1.0)

1.0 sürümü · 25 Kasım 2026 tarihinde güncellendi

Bu örnek şu kaynakları kullanıyor

Semboller, öznitelikleri doldurulmuş olarak kendi kütüphanelerimizden gelen bloklardır. Pafta ve anteti, ISO A3 antet şablonumuzdan gelir. Kendi şemalarınızı çizmek için bunları indirin.

ZIP'in içinde ne var

  • GIS-Substation-Double-Busbar-Sample.dwg
    Örnek çizim (DWG, AutoCAD 2018 biçimi)
  • Electrical-Template-ISO-A3.dwt
    Çizimin üzerinde hazırlandığı şablon (DWT)
  • CADXChange-Monochrome.ctb
    Tüm renkleri siyah basan plot stili tablosu (CTB)
  • README.txt
    Layer listesi ve dosyaların kullanımını anlatan README

Şablon

Elektrik şablonunda renkleri, çizgi kalınlıkları ve çizgi tipleriyle 16 layer vardır (güç devreleri, baralar, kumanda, sinyal, koruma topraklaması, kabin sınırları, yazı ve daha fazlası); ayrıca ISO-2.5'ten ISO-5'e yazı stilleri, ISO-25 ölçü stili ve antet ile revizyon tablosu olan bir ISO A3 layout'u bulunur. Layer adları yaygın bir düzendir, bir standart değildir; şirketinizin kurallarına uysun diye yeniden adlandırın.

Tanımlı layer'lar

Şablondaki her layer; rengi, çizgi kalınlığı ve çizgi tipiyle, ve bu örneğin kaç nesnesinin üzerinde olduğuyla. Örneğin kullanmadığı layer'lar da tanımlı kalır, kendi çiziminiz için hazırdır.

LayerRenkÇizgi kalınlığıÇizgi tipiKullanımBuradaki nesneler
Elektrik layer'ları
ELEC-POWER10.50 mmContinuousAna güç devreleri45
ELEC-BUS10.70 mmContinuousBaralar ve kalın çizgiler2
ELEC-CONTROL40.25 mmContinuousKumanda devreleriburada kullanılmıyor
ELEC-SIGNAL30.18 mmContinuousSinyal, enstrümantasyon ve haberleşme devreleriburada kullanılmıyor
ELEC-PE20.35 mmContinuousKoruma topraklaması ve eşpotansiyel bağlantıburada kullanılmıyor
ELEC-CABLE300.25 mmDASHEDKablo, boru ve kablo tavası güzergâhlarıburada kullanılmıyor
SYMBOL70.25 mmContinuousSemboller (sembol kütüphanelerinin kullandığı layer)42
ELEC-TERMINAL70.25 mmContinuousKlemensler ve bağlantı noktalarıburada kullanılmıyor
ELEC-BOUNDARY50.18 mmDASHDOTKabin, pano ve cihaz sınırlarıburada kullanılmıyor
ELEC-MECH-LINK80.18 mmDASHEDMekanik bağlantılar, kilitlemeler ve ölçüm bağlantılarıburada kullanılmıyor
ELEC-REF70.18 mmContinuousReferans tanımlamaları (-QF1, -K2)burada kullanılmıyor
ELEC-WIRE-NO70.18 mmContinuousTel numaraları ve kablo etiketleriburada kullanılmıyor
ELEC-XREF90.13 mmContinuousKontak ve çapraz referans yazılarıburada kullanılmıyor
ELEC-TEXT70.18 mmContinuousGenel yazı103
ELEC-NOTES70.18 mmContinuousNotlar ve lejantlar7
ELEC-DIM30.18 mmContinuousÖlçülendirmeburada kullanılmıyor
Pafta ve sembol layer'ları
07varsayılanContinuousVarsayılan layer, boş bırakınburada kullanılmıyor
FRAME7varsayılanContinuousPafta kenarı5
TITLEBLOCK7varsayılanContinuousAntet ve revizyon tablosu1
VIEWPORT8varsayılanContinuousLayout viewport çerçevesi (basılmaz)2
DRAWING-AREA8varsayılanContinuousModel çizim alanı sınırı (basılmaz)2

Tanımlı stiller

Şablonun tanımladığı yazı stilleri, ölçü stili ve çizgi tipleri; böylece her yeni çizimde kurmanız gerekmez.

TürAdAyarlar
Yazı stiliISOisocp.shx, 15°, değişken yükseklik
Yazı stiliISO-2.5isocp.shx, 15°, 2.5 mm yükseklik
Yazı stiliISO-3.5isocp.shx, 15°, 3.5 mm yükseklik
Yazı stiliISO-5isocp.shx, 15°, 5 mm yükseklik
Yazı stiliTB-enArial, antette kullanılır
Ölçü stiliISO-25Yazı 2.5 mm, oklar 2.5 mm, uzatma çizgileri ölçü çizgisinin 1.25 mm ötesine uzanır ve nesneden 0.625 mm uzakta durur, ölçü çizgileri arası 3.75 mm, 0 ondalık
Çizgi tipiContinuousSürekli çizgi
Çizgi tipiDASHEDKesikli
Çizgi tipiDASHDOTÇizgi-nokta
Çizgi tipiCENTEREksen çizgisi
Çizgi tipiPHANTOMHayalet çizgi
Çizgi tipiHIDDENGizli çizgi

Pafta ve çizim ayarı

Paftanın nasıl ayarlandığı; böylece kendi çizimleriniz de aynı şekilde basılır.

Pafta
ISO A3 yatay, 420 × 297 mm.
Layout
ISO-A3 adlı tek bir layout; kenar boşluksuz A3 ortamında 1:1 basılır, yani paftada yazıcı kenar boşluğu yoktur.
Çerçeve
Sol kenardan 20 mm (cilt tarafı) ve diğer kenarlardan 10 mm; içerideki çizim alanı 390 × 277 mm'dir.
Model uzayı
Birim milimetredir. Çizim alanı 1:1 gösterilir; yani çizimdeki 1 mm kâğıtta 1 mm'dir.
Antet
Sağ altta 160 × 79 mm; şirket, proje, başlık ve onay alanlarının üstünde dört satırlık bir revizyon tablosu bulunur.
Yazı boyutu
Etiketler ve notlar için 2,5 mm, başlıklar için 3,5 mm ve 5 mm.
Çizgi tipi ölçeği
1; yani çizgi aralıkları 1:1 basım için boyutlandırılmıştır.
Plot stili
Ayarlanmamış. Siyah-beyaz baskı için sayfa yapısında ZIP'teki CTB'yi seçin.

Antet alanları

Antetin öznitelikleri.

ÖznitelikPaftadaki alanBu örnekteki değer
COMPANYCOMPANYCADXChange
PROJECTPROJECT110 kV Substation
AREAAREA110 kV GIS
SYSTEMSYSTEM110 kV, 50 Hz
CLIENTCLIENTSample
TITLEDRAWING TITLEGIS single-line diagram, double busbar
DRAWING_NODRAWING NO.E-502
CONTRACT_NOCONTRACT NO.—
REVREVA
DRAWNDRAWN—
CHECKEDCHECKED—
APPROVEDAPPROVED—
DATEDATE2026-11-25
SCALESCALENTS
SHEETSHEET1
SHEET_OFOF1

Revizyon tablosu: R1–R4, her biri REV, TARİH, AÇIKLAMA ve YAPAN alanlarıyla (16 öznitelik, bu örnekte boş).

Çizimdeki bloklar

Çizimin ekipman listesi: blok adı, sembol ve kaç kez yerleştirildiği.

SembolBlokYerleştirilen
GIS disconnector modulePRI_GISM_DS16
GIS breaker modulePRI_GISM_CB5
GIS current transformerPRI_GISM_CT5
GIS fast earthing modulePRI_GISM_ES_FAST4
GIS surge arresterPRI_GISM_ARRESTER4
GIS SF6-air bushingPRI_GISM_BUSHING2
GIS cable end modulePRI_GISM_CABLE_END2
Transformer with on-load tap changerPRI_TX_OLTC2
GIS voltage transformerPRI_GISM_VT2

Ekipman listesi

Yerleştirilen her sembol için bir satır; çizimdeki blokların özniteliklerinden okunur: paftada gösterilenler ve doldurulmuş ama gösterilmeyen liste öznitelikleri.

EtiketAçıklamaPaftada gösterilenDoldurulmuş, gösterilmeyen
QS11GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS12GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF1GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA1GIS current transformerPRI_GISM_CTRATIO = 1200/1 ACLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS13GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QE1GIS fast earthing modulePRI_GISM_ES_FASTRATED_CURRENT_A = -SHORT_TIME_KA = 40EARTHING_SWITCH = Fast-actingMECHANISM = Spring
F1GIS surge arresterPRI_GISM_ARRESTERMCOV_KV = 84DISCHARGE_KA = 10HOUSING = Metal-enclosed
B1GIS SF6-air bushingPRI_GISM_BUSHINGCABLE_TYPE = SF6-air bushingRATED_CURRENT_A = 1250
QS21GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS22GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF2GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA2GIS current transformerPRI_GISM_CTRATIO = 1200/1 ACLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS23GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QE2GIS fast earthing modulePRI_GISM_ES_FASTRATED_CURRENT_A = -SHORT_TIME_KA = 40EARTHING_SWITCH = Fast-actingMECHANISM = Spring
F2GIS surge arresterPRI_GISM_ARRESTERMCOV_KV = 84DISCHARGE_KA = 10HOUSING = Metal-enclosed
B2GIS SF6-air bushingPRI_GISM_BUSHINGCABLE_TYPE = SF6-air bushingRATED_CURRENT_A = 1250
QS41GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS42GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF4GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA4GIS current transformerPRI_GISM_CTRATIO = 600/1 ACLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS43GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QE4GIS fast earthing modulePRI_GISM_ES_FASTRATED_CURRENT_A = -SHORT_TIME_KA = 40EARTHING_SWITCH = Fast-actingMECHANISM = Spring
F4GIS surge arresterPRI_GISM_ARRESTERMCOV_KV = 84DISCHARGE_KA = 10HOUSING = Metal-enclosed
T1Transformer with on-load tap changerPRI_TX_OLTCRATING_MVA = 63 MVAVOLTAGE_RATIO = 110/10.5 kVVECTOR_GROUP = YNd11IMPEDANCE_PCT = 12TAP_RANGE = +/-9x1.25%COOLING = ONAN/ONAFNEUTRAL_EARTHING = Solid
QS51GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS52GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF5GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA5GIS current transformerPRI_GISM_CTRATIO = 600/1 ACLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS53GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QE5GIS fast earthing modulePRI_GISM_ES_FASTRATED_CURRENT_A = -SHORT_TIME_KA = 40EARTHING_SWITCH = Fast-actingMECHANISM = Spring
F5GIS surge arresterPRI_GISM_ARRESTERMCOV_KV = 84DISCHARGE_KA = 10HOUSING = Metal-enclosed
T2Transformer with on-load tap changerPRI_TX_OLTCRATING_MVA = 63 MVAVOLTAGE_RATIO = 110/10.5 kVVECTOR_GROUP = YNd11IMPEDANCE_PCT = 12TAP_RANGE = +/-9x1.25%COOLING = ONAN/ONAFNEUTRAL_EARTHING = Solid
QS31GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF3GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA3GIS current transformerPRI_GISM_CTCLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS32GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS71GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
TV1GIS voltage transformerPRI_GISM_VTCLASS = 0.2 / 3PBURDEN_VA = 50WINDINGS = 2RATED_KV = 126
QS81GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
TV2GIS voltage transformerPRI_GISM_VTCLASS = 0.2 / 3PBURDEN_VA = 50WINDINGS = 2RATED_KV = 126

Üretici, model ve açıklamalar her blokta boş bırakılmıştır, verileriniz için hazırdır. Değerler örnektir.

Nasıl kullanılır

  1. Layer'ların, yazıların ve anteti nasıl kullanıldığını görmek için örnek çizimi açın; ya da önce tarayıcıda açın, hiçbir şey kurmanız gerekmez.
  2. Kendi çiziminize şablondan başlayın (NEW, sonra DWT dosyasını seçin). Siyah-beyaz baskı istiyorsanız CTB dosyasını plot stilleri klasörünüze kopyalayın.
  3. Sembol kütüphanesinden bloklarınızı çiziminize ekleyin. Örnekteki bloklar kopyadır; kütüphane değiştiğinde değişmezler.

Sık sorulan sorular

Çizimi gerçek bir projede kullanabilir miyim?
Yerleşim ve layer düzeni için bir başlangıç noktası olarak evet. Anma değerleri, ayarlar ve kablo kesitleri uydurmadır; bu yüzden şema, tasarım ya da inşaat için kullanılmadan önce projenize göre kontrol edilip değiştirilmelidir.
Layer'lar neden renkli?
Renkler ve çizgi kalınlıkları layer'ları izler: güç devreleri kırmızı ve kalın, kumanda camgöbeği, sinyal yeşildir. ZIP'teki plot stili tablosu her şeyi siyah basar ve çizgi kalınlıklarını korur; yani siyah-beyaz da basabilirsiniz.
Hangi CAD programları açar?
Çizim ve şablon, AutoCAD 2018 ve sonrasının açtığı AutoCAD 2018 biçimindedir; bu biçimi okuyan diğer CAD programları da açar. Tarayıcı görüntüleyici hiçbir kurulum gerektirmez.