KaynaklarDWG sembol kütüphaneleri
AutoCAD power system primary equipment symbols (DWG): the power-carrying side of a single-line diagram
Power system primary equipment symbols: 448 hazır AutoCAD bloğu (DWG). 24 sembollük başlangıç paketi ücretsiz; Standart sürüm $19.
Ücretsiz başlangıç paketi: 24 sembol
Bu kütüphanenin en çok kullanılan sembolleri, tek bir DWG içinde AutoCAD bloğu olarak. Herkes için ücretsiz, her projede kullanılabilir.
Transformer, two winding
Transformer, delta-star
Transformer, delta-star, neutral earthed
Transformer with on-load tap changer
Autotransformer
Transformer, three winding
Pad-mounted transformer
Station service transformer
Single busbar scheme
Double busbar scheme
Ring busbar scheme
H scheme, line breakers
Bridge scheme, TX breakers
Thyristor valve
Converter, line-commutated
HVDC back-to-back station
Neutral isolated
Neutral earthed via resistor
Neutral via Petersen coil
Coupling capacitor, coil
Post insulator
Line, bundle of 2
Cable termination, outdoor
Cables in parallel, two
Standart: 122 sembol
Standart sürümün 122 sembolünün tamamı tek indirmede, doğrudan AutoCAD'e eklemeye hazır. Bir kez ödeyin, dosyalar sizde kalsın.
Generator, synchronous
Generator, induction
Generator, DC
Hydro generator
Steam turbine generator
Gas turbine generator
Diesel generator set
Cell
AC source
Motor, three-phase
Motor, single-phase
Generator, three-phase
Rectifier
Inverter
DC/DC converter
Frequency converter
Photovoltaic generator
Motor, slip-ring
Motor, induction
Motor, synchronous
Motor, DC
Load (static)
Load (static), solid
Load, resistive
Transformer, two winding
Transformer, delta-star
Transformer, star-star
Transformer, delta-star, neutral earthed
Transformer, delta-delta
Transformer with on-load tap changer
Autotransformer
Transformer, three winding
Earthing transformer (zigzag)
Phase-shifting transformer
Pad-mounted transformer
Station service transformer
Transformer, polarity dots
Autotransformer, circle
Transformer, var. coupling
CT, two secondary windings
CT, secondary with tap
CT, five primary passages
Pulse CT, three conductors
Pulse CT, two secondaries
Transformer, D-Y, windings
Tx D-Y, tap changer, wdg
Winding, delta
Winding, open delta
Winding, star
Winding, star with neutral
Brush (slip-ring or commutator)
Circuit breaker
Circuit breaker, box, open
Circuit breaker, box, closed
Circuit breaker, vacuum
Circuit breaker, SF6
Air circuit breaker
Generator circuit breaker
Circuit breaker, three pole
Recloser
Sectionalizer
Busbar
Busbar, double
Busbar with section break
Bus tie breaker
Junction
Crossing, not connected
Overhead line
Overhead line, double circuit
Cable
Cable sealing end
Cable joint
Current transformer
Current transformer, two cores
Current transformer, three cores
Zero-sequence CT (core balance)
Reactor, series
Reactor, shunt
Neutral grounding reactor
Neutral grounding resistor
Thyristor controlled reactor (TCR)
Thyristor switched capacitor (TSC)
Mechanically switched capacitor (MSC)
Feeder bay: disconnector, breaker, CT
Incomer bay: disconnector, breaker, CT
Transformer bay: breaker and transformer
Line bay: disconnector, breaker, CT
Generator bay: breaker and generator
Bus section: disconnectors and breaker
GIS enclosure and conductor
GIS compartment end, sealed
GIS compartment partition
GIS partition, two chambers
GIS gas through spacer
Moulded case circuit breaker
Miniature circuit breaker
Residual current device
Isolating switch
Excitation, static (thyristor)
Substation, in service
Hydro station, planned
Hydro station, in service
Thermal station, planned
Transformer, forced cooling
Transformer, dry type
Single busbar scheme
Double busbar scheme
Ring busbar scheme
H scheme, line breakers
Bridge scheme, TX breakers
Thyristor valve
Converter leg (two valves)
Converter, line-commutated
HVDC back-to-back station
Coupling capacitor, coil
Post insulator
Line, bundle of 2
Cable termination, outdoor
Cables in parallel, two
Neutral isolated
Neutral earthed via resistor
Neutral via Petersen coil
Pro: 448 sembolün tamamı
Kütüphanenin her sembolü, toplam 448, tek indirmede. Standart bunlardan 122 tanesini içerir. Bir kez ödeyin, dosyalar sizde kalsın.
Ücretsiz başlangıç paketi
$0Herkes için, her proje için
- 24 sembol
- Giriş gerekmez
- Tek DWG dosyası
Kütüphane lisansı
$19
Bir kişi için
Education: free
- Tek seferlik ödeme
Student or teacher?
Free for one year with your school e-mail address. Renew it with the same address.
Sign in with your school e-mail address, we check it, and the licence is added to your account.
YakındaOkul ya da üniversite e-posta adresiyle ücretsiz; öğrenim ve eğitim için.
Pro lisansı
$49
Bir kişi için
Education: $24.50
- Tek seferlik ödeme
Student or teacher?
Half price ($24.50) for one year with your school e-mail address. Buy again next year to renew.
Sign in with your school e-mail address, we check it, and you pay half price.
YakındaHalf price ($24.50) for one year with your school e-mail address. Buy again next year to renew.
Her sürüm neleri içerir
Semboller gruplara göre, her sürümün her gruptan kaç sembol içerdiğiyle birlikte.
| İçerik | Ücretsiz | Standart | Pro |
|---|---|---|---|
| Tüm semboller | 24 | 122 | 448 |
| Bu sürümün eklediği | — | +98 | +326 |
| Generators and sources | — | 7 | 25 |
| Rotating machines (IEC) | — | 11 | 37 |
| Motors and loads | — | 6 | 20 |
| Power transformers | 8 | 12 | 40 |
| Transformers, winding form | — | 10 | 33 |
| Winding connections | — | 5 | 18 |
| Circuit breakers and switches | — | 10 | 37 |
| Disconnector and earthing types | — | — | 9 |
16 grup daha gösterDaha az grup göster
| Busbars, lines and cables | — | 11 | 38 |
|---|---|---|---|
| Instrument transformers | — | 4 | 19 |
| Reactors, capacitors and arresters | — | 4 | 12 |
| Reactive compensation and filters | — | 3 | 15 |
| Switchgear bays | — | 6 | 20 |
| Gas-insulated switchgear | — | 5 | 18 |
| GIS modules (SF6) | — | — | 13 |
| Low voltage distribution | — | 4 | 15 |
| Generator excitation and auxiliaries | — | 1 | 4 |
| Power stations and substations | — | 4 | 13 |
| Substation equipment | — | 2 | 7 |
| Busbar schemes | 5 | 5 | 13 |
| HVDC and converters | 3 | 4 | 19 |
| Line equipment | 3 | 3 | 11 |
| Cable systems | 2 | 2 | 8 |
| Neutral earthing | 3 | 3 | 4 |
Pro, Standart'taki tüm sembolleri ve yalnızca Pro'da bulunanları içerir.
448 symbols as ready-to-use AutoCAD blocks for the primary side of a power system, the equipment that carries the power: generators and motors, two- and three-winding transformers in circle and winding form, circuit breakers, disconnectors and earthing switches, busbars, lines and cables, instrument transformers (the bodies, as drawn on a single-line diagram), reactors, capacitors and arresters, reactive compensation, switchgear bays and gas-insulated switchgear, power station and substation outlines, ready-made busbar schemes (single, double, ring, H, bridge, transfer bus), HVDC valves, converters and links, line and cable equipment, and neutral earthing. Protection, control and metering belong to the secondary side and are not in this library; current and voltage transformers appear here as the bodies of the single-line diagram. For high-voltage substations it adds the yard disconnector types, fast-acting earthing switches, series compensation, combined and optical instrument transformers, HVDC switching and SF6 gas-insulated modules with hybrid bays and gas-insulated lines.
Sürüm 1.1 · güncelleme: 24 Kasım 2026 · Nelerin değiştiğine göz atın
Bu kütüphaneyle hazırlanan örnek çizimler
Tüm 448 sembol
448 sembolün 448 tanesi
Generator, synchronous
PRI_GEN_SYNCÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCGenerator, induction
PRI_GEN_ASYNCÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCGenerator, DC
PRI_GEN_DCÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCHydro generator
PRI_GEN_HYDROÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCSteam turbine generator
PRI_GEN_STEAMÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCGas turbine generator
PRI_GEN_GASÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCDiesel generator set
PRI_GEN_DIESELÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCGrid infeed (utility source)
PRI_GRIDÖznitelikler
TAGRATINGVOLTAGE_KVUNITSMANUFACTURERMODELREMARKSDESCSynchronous condenser
PRI_SYNC_CONDÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCGas engine generator set
PRI_GEN_GASENGINEÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCPumped storage motor-generator
PRI_GEN_PUMPEDÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCSupercapacitor energy storage
PRI_SUPERCAPÖznitelikler
TAGRATINGVOLTAGE_KVUNITSMANUFACTURERMODELREMARKSDESCCombined heat and power set
PRI_GEN_CHPÖznitelikler
TAGRATING_MVAVOLTAGE_KVPOWER_FACTORSPEED_RPMEXCITATIONCOOLINGMANUFACTURERMODELREMARKSDESCMotor, three-phase
PRI_IEC_MOTOR_3PHÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYMANUFACTURERPART_NODESCMotor, single-phase
PRI_IEC_MOTOR_1PHÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYMANUFACTURERPART_NODESCGenerator, three-phase
PRI_IEC_GENERATOR_3PHÖznitelikler
TAGRATING_KVAVOLTAGECURRENTFREQUENCYSPEED_RPMMANUFACTURERPART_NODESCRectifier
PRI_IEC_RECTIFIERÖznitelikler
TAGPOWER_KWINPUT_VOUTPUT_VOUTPUT_AEFFICIENCY_PCTSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCInverter
PRI_IEC_INVERTERÖznitelikler
TAGPOWER_KWINPUT_VOUTPUT_VOUTPUT_AEFFICIENCY_PCTSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCDC/DC converter
PRI_IEC_DC_CONVERTERÖznitelikler
TAGPOWER_KWINPUT_VOUTPUT_VOUTPUT_AEFFICIENCY_PCTSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCFrequency converter
PRI_IEC_FREQUENCY_CONVERTERÖznitelikler
TAGPOWER_KWINPUT_VOUTPUT_HZOUTPUT_APROTECTIONSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPhotovoltaic generator
PRI_IEC_PV_GENERATORÖznitelikler
TAGPOWER_KWPVOLTAGECURRENTMODULESSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMotor, slip-ring
PRI_IEC_MOTOR_WOUNDÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMROTOR_VSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMotor, stepper
PRI_IEC_MOTOR_STEPPERÖznitelikler
TAGTORQUE_NMVOLTAGECURRENTSTEP_ANGLESTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMotor, DC, separate field
PRI_IEC_MOTOR_DC_SEPÖznitelikler
TAGPOWER_KWVOLTAGECURRENTFIELD_VSPEED_RPMMANUFACTURERPART_NODESCMotor, DC, shunt field
PRI_IEC_MOTOR_DC_SHUNTÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMotor, DC, series field
PRI_IEC_MOTOR_DC_SERIESÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCGenerator, single-phase
PRI_IEC_GENERATOR_1PHÖznitelikler
TAGRATING_KVAVOLTAGECURRENTFREQUENCYSPEED_RPMMANUFACTURERPART_NODESCMachine, general symbol
PRI_IEC_MACHINEÖznitelikler
TAGPOWER_KWVOLTAGECURRENTTYPESTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMotor, linear
PRI_IEC_MOTOR_LINEARÖznitelikler
TAGFORCE_NVOLTAGECURRENTSTROKE_MMSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMotor, star-connected
PRI_IEC_MOTOR_STARÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMotor with brake
PRI_IEC_MOTOR_BRAKEÖznitelikler
TAGPOWER_KWVOLTAGECURRENTBRAKE_VBRAKE_NMMANUFACTURERPART_NODESCVoltage source
PRI_IEC_SOURCE_VOLTAGEÖznitelikler
TAGVOLTAGEINTERNAL_OHMSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCCurrent source
PRI_IEC_SOURCE_CURRENTÖznitelikler
TAGCURRENTCOMPLIANCE_VSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMotor, single-phase, series
PRI_IEC_MOTOR_1PH_SERIESÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMotor, synchronous, single-phase
PRI_IEC_MOTOR_SYNC_1PHÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCGenerator, synchronous, permanent magnet
PRI_IEC_GENERATOR_SYNC_PMÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCGenerator, synchronous, star with neutral
PRI_IEC_GENERATOR_SYNC_STAR_NÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYMANUFACTURERPART_NODESCSynchronous converter, three-phase
PRI_IEC_CONVERTER_SYNCÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCInduction motor, single-phase, two windings
PRI_IEC_MOTOR_INDUCTION_1PH_AUXÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYMANUFACTURERPART_NODESCLinear induction motor, three-phase
PRI_IEC_MOTOR_LINEAR_3PHÖznitelikler
TAGPOWER_KWVOLTAGECURRENTSPEED_RPMFREQUENCYSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCRectifier, bridge connection
PRI_IEC_RECTIFIER_BRIDGEÖznitelikler
TAGTYPEVOLTAGECURRENTPACKAGESTD_CLAUSESTD_REFMANUFACTURERPART_NODESCRectifier/inverter
PRI_IEC_RECTIFIER_INVERTERÖznitelikler
TAGPOWER_KWINPUT_VOUTPUT_VOUTPUT_AEFFICIENCY_PCTSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCStatic generator
PRI_IEC_STATIC_GENERATORÖznitelikler
TAGRATINGMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCHeat source, general
PRI_IEC_HEAT_SOURCEÖznitelikler
POWERMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCHeat source, combustion
PRI_IEC_HEAT_SOURCE_COMBUSTIONÖznitelikler
POWERFUELMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFan, in housing
PRI_IEC_FAN_IN_HOUSINGÖznitelikler
TAGFLOW_M3HMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCPump, in housing
PRI_IEC_PUMP_IN_HOUSINGÖznitelikler
TAGFLOW_M3HMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCMotor, induction
PRI_MOTOR_IMÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCMotor, synchronous
PRI_MOTOR_SMÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCMotor, DC
PRI_MOTOR_DCÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCLoad (static)
PRI_LOADÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCLoad (static), solid
PRI_LOAD_FILLÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCLoad, resistive
PRI_LOAD_RESISTIVEÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCLighting load
PRI_LOAD_LIGHTÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCHeater
PRI_LOAD_HEATERÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCArc furnace
PRI_LOAD_ARCÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCElectrolyser
PRI_LOAD_ELECTROLYSERÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCVariable frequency drive
PRI_VFDÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCSoft starter
PRI_SOFTSTARTÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCEV charger
PRI_LOAD_EVÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCHeat pump
PRI_LOAD_HEATPUMPÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCData centre load
PRI_LOAD_DATAÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCWelding machine
PRI_LOAD_WELDERÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCLift / crane drive
PRI_LOAD_LIFTÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCRectifier set (electrolysis)
PRI_LOAD_RECTSETÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCLoad, inductive
PRI_LOAD_INDÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCLoad, capacitive
PRI_LOAD_CAPÖznitelikler
TAGPOWER_KWVOLTAGEPOWER_FACTORSTARTINGSERVICEMANUFACTURERMODELREMARKSDESCTransformer, two winding
PRI_TX_2WÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, delta-star
PRI_TX_DYÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, star-star
PRI_TX_YYÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, delta-star, neutral earthed
PRI_TX_DYNÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, delta-delta
PRI_TX_DDÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer with on-load tap changer
PRI_TX_OLTCÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCAutotransformer
PRI_TX_AUTOÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, three winding
PRI_TX_3WÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCEarthing transformer (zigzag)
PRI_TX_ZIGZAGÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCPhase-shifting transformer
PRI_TX_PHASEÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCPad-mounted transformer
PRI_TX_PADÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCPole-mounted transformer with fuse
PRI_TX_POLEÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCVoltage regulator
PRI_TX_REGULATORÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCStation service transformer
PRI_TX_STATIONÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, star-delta
PRI_TX_YDÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, star-delta, neutral earthed
PRI_TX_YNDÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, star-star, both neutrals earthed
PRI_TX_YNYNÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, three winding, delta tertiary
PRI_TX_3W_YYDÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, delta-star, on-load tap changer
PRI_TX_DY_OLTCÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, star-delta, on-load tap changer
PRI_TX_YD_OLTCÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, three winding, on-load tap changer
PRI_TX_3W_OLTCÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCAutotransformer, on-load tap changer
PRI_TX_AUTO_OLTCÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer (circles)
PRI_IEC_TRANSFORMERÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCTransformer (windings)
PRI_IEC_TRANSFORMER_WINDINGSÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCTransformer, three windings
PRI_IEC_TRANSFORMER_3WÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VTERTIARY_VVECTOR_GROUPFREQUENCYSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCTransformer, tap changer
PRI_IEC_TRANSFORMER_TAPSÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VTAP_RANGEVECTOR_GROUPIMPEDANCE_PCTMANUFACTURERPART_NODESCTransformer, screened
PRI_IEC_TRANSFORMER_ISOLATINGÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VFREQUENCYPROTECTIONMANUFACTURERPART_NODESCCurrent transformer, 2 cores
PRI_IEC_CT_2COREÖznitelikler
TAGRATIOCORE1CORE2SECONDARY_AMANUFACTURERPART_NODESCTransformer, 3-phase, star-delta
PRI_IEC_TRANSFORMER_3PH_STAR_DELTAÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCTransformer, 3-phase, star-star
PRI_IEC_TRANSFORMER_3PH_STAR_STARÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCTransformer, 3-phase, star-zigzag
PRI_IEC_TRANSFORMER_3PH_STAR_ZIGÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCTransformer, 3-phase, tap changer
PRI_IEC_TRANSFORMER_3PH_TAP_CHANGERÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCTransformer, 3-phase, four taps
PRI_IEC_TRANSFORMER_3PH_TAPS_4Öznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCTransformer bank, 1-phase units, star-delta
PRI_IEC_TRANSFORMER_BANK_STAR_DELTAÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCTransformer, 3-phase, star-star-delta
PRI_IEC_TRANSFORMER_3W_STAR_STAR_DELTAÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCAutotransformer, single-phase
PRI_IEC_AUTOTRANSFORMER_CIRCLEÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCAutotransformer, 3-phase, star
PRI_IEC_AUTOTRANSFORMER_3PH_STARÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCAutotransformer, voltage regulation
PRI_IEC_AUTOTRANSFORMER_REGULATEDÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCInduction regulator, 3-phase
PRI_IEC_INDUCTION_REGULATORÖznitelikler
TAGRATING_KVAPRIMARY_VSECONDARY_VVECTOR_GROUPFREQUENCYIMPEDANCE_PCTMANUFACTURERPART_NODESCPulse transformer
PRI_IEC_PULSE_TRANSFORMERÖznitelikler
TAGRATIOPULSE_WIDTHMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCTransformer, polarity dots
PRI_MCH_S00843_TRANSFORMER_POLARITY_DOTSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAutotransformer, circle
PRI_MCH_S00846_AUTOTRANSFORMER_CIRCLEÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCTransformer, var. coupling
PRI_MCH_S00856_TRANSFORMER_VAR_COUPLINGÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCT, two secondary windings
PRI_MCH_S00882_CT_TWO_SECONDARY_WINDINGSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCT, secondary with tap
PRI_MCH_S00884_CT_SECONDARY_WITH_TAPÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCT, five primary passages
PRI_MCH_S00886_CT_FIVE_PRIMARY_PASSAGESÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCPulse CT, three conductors
PRI_MCH_S00888_PULSE_CT_THREE_CONDUCTORSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCPulse CT, two secondaries
PRI_MCH_S00890_PULSE_CT_TWO_SECONDARIESÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCTransformer, D-Y, windings
PRI_MCH_S00859_TRANSFORMER_D_Y_WINDINGSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCTx D-Y, tap changer, wdg
PRI_MCH_S00865_TX_D_Y_TAP_CHANGER_WDGÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCTx Y-Y, four taps, windings
PRI_MCH_S00861_TX_Y_Y_FOUR_TAPS_WINDINGSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCTransformer, Y-Y-D, windings
PRI_MCH_S00869_TRANSFORMER_Y_Y_D_WINDINGSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCBank, 1-ph units, D-Y, wdg
PRI_MCH_S00863_BANK_1_PH_UNITS_D_Y_WDGÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAutotransf. 3-ph, windings
PRI_MCH_S00873_AUTOTRANSF_3_PH_WINDINGSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAutotransf. reg., circle
PRI_MCH_S00874_AUTOTRANSF_REG_CIRCLEÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAutotransf. reg., windings
PRI_MCH_S00875_AUTOTRANSF_REG_WINDINGSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCInduction regulator, circle
PRI_MCH_S00876_INDUCTION_REGULATOR_CIRCLEÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCT, two cores, one sec. each
PRI_MCH_S00880_CT_TWO_CORES_ONE_SEC_EACHÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCT winding, two cores
PRI_MCH_S00881_CT_WINDING_TWO_CORESÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCT winding, two secondaries
PRI_MCH_S00883_CT_WINDING_TWO_SECONDARIESÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCT winding, one tap
PRI_MCH_S00885_CT_WINDING_ONE_TAPÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCT winding, five passages
PRI_MCH_S00887_CT_WINDING_FIVE_PASSAGESÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCT winding, three conductors
PRI_MCH_S00889_CT_WINDING_THREE_CONDUCTORSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCPulse CT winding, two sec.
PRI_MCH_S00891_PULSE_CT_WINDING_TWO_SECÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCPhase shifter, three-phase
PRI_GAI_S01837_PHASE_SHIFTER_THREE_PHASEÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCPhase shifter, 3-ph, wound
PRI_GAI_S01838_PHASE_SHIFTER_3_PH_WOUNDÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCBushing VT, single-pole
PRI_GAI_S01839_BUSHING_VT_SINGLE_POLEÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCBushing VT, two winding
PRI_GAI_S01840_BUSHING_VT_TWO_WINDINGÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCBushing CT, single-pole
PRI_GAI_S01841_BUSHING_CT_SINGLE_POLEÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCAutotransformer, tertiary
PRI_GAI_S01913_AUTOTRANSFORMER_TERTIARYÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCAutotransformer, tertiary 2
PRI_GAI_S01914_AUTOTRANSFORMER_TERTIARY_2Öznitelikler
REMARKSSTD_CLAUSESTD_REFDESCThree separate windings
PRI_MCH_S00797_THREE_SEPARATE_WINDINGSÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCFour-phase, neutral out
PRI_MCH_S00804_FOUR_PHASE_NEUTRAL_OUTÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCSix-phase, double delta
PRI_MCH_S00811_SIX_PHASE_DOUBLE_DELTAÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCSix-phase winding, star
PRI_MCH_S00813_SIX_PHASE_WINDING_STARÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCCircuit breaker
PRI_CBÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCCircuit breaker, box, open
PRI_CB_BOX_OPENÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCCircuit breaker, box, closed
PRI_CB_BOX_CLOSEDÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCCircuit breaker, vacuum
PRI_CB_VCBÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCCircuit breaker, SF6
PRI_CB_SF6Öznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCAir circuit breaker
PRI_CB_ACBÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCGenerator circuit breaker
PRI_CB_GENÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCCircuit breaker, three pole
PRI_CB_3PÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCRecloser
PRI_RECLOSERÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCSectionalizer
PRI_SECTIONALIZERÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCDisconnector
PRI_DISCONNECTORÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCDisconnector, closed
PRI_DISCONNECTOR_CLOSEDÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCEarthing switch
PRI_EARTH_SWITCHÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCLoad break switch
PRI_LOAD_BREAKÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCSwitch-disconnector
PRI_SWITCH_DISCÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCFuse
PRI_FUSEÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KACHARACTERISTICMANUFACTURERMODELREMARKSDESCFuse-switch disconnector
PRI_FUSE_SWITCHÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KACHARACTERISTICMANUFACTURERMODELREMARKSDESCContactor
PRI_CONTACTORÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCAutomatic transfer switch
PRI_ATSÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCStatic transfer switch
PRI_STSÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCDisconnector with earthing switch
PRI_DISC_ESÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCDisconnector with two earthing switches
PRI_DISC_2ESÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCDisconnector, three pole
PRI_DISC_3PÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCEarthing switch, three pole
PRI_ES_3PÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCLoad break switch, three pole
PRI_LBS_3PÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCLoad break switch with earthing switch
PRI_LBS_ESÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCLoad break switch with fuse
PRI_LBS_FUSEÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KACHARACTERISTICMANUFACTURERMODELREMARKSDESCContactor with fuse
PRI_CONTACTOR_FUSEÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KACHARACTERISTICMANUFACTURERMODELREMARKSDESCCircuit breaker with earthing switch
PRI_CB_ESÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCFuse cutout (drop-out)
PRI_FUSE_CUTOUTÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KACHARACTERISTICMANUFACTURERMODELREMARKSDESCFuse, three pole
PRI_FUSE_3PÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KACHARACTERISTICMANUFACTURERMODELREMARKSDESCCurrent limiter (power cable)
PRI_CURRENT_LIMITERÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KACHARACTERISTICMANUFACTURERMODELREMARKSDESCCircuit breaker, withdrawable
PRI_CB_WDÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCContactor, withdrawable
PRI_CONTACTOR_WDÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCBreaker, closing resistor
PRI_CB_CLOSING_RESÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCBreaker, grading capacitors
PRI_CB_GRADING_CAPÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCDead-tank breaker with CTs
PRI_CB_DEAD_TANKÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCCentre-break disconnector
PRI_DS_CENTRE_BREAKÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCDouble-break disconnector
PRI_DS_DOUBLE_BREAKÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCVertical-break disconnector
PRI_DS_VERTICAL_BREAKÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCKnee-type disconnector
PRI_DS_KNEEÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCPantograph disconnector
PRI_DS_PANTOGRAPHÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCSemi-pantograph disconnector
PRI_DS_SEMI_PANTOÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCEarthing switch, fast-acting
PRI_ES_FASTÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCEarthing switch, motor drive
PRI_ES_MOTORÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCDisconnector, motor drive
PRI_DS_MOTORÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCBusbar, double
PRI_BUS_DOUBLEÖznitelikler
TAGVOLTAGE_KVRATED_CURRENT_ACONDUCTORSHORT_CIRCUIT_KAREMARKSDESCBusbar with section break
PRI_BUS_SECTIONÖznitelikler
TAGVOLTAGE_KVRATED_CURRENT_ACONDUCTORSHORT_CIRCUIT_KAREMARKSDESCBus tie breaker
PRI_BUS_TIEÖznitelikler
TAGVOLTAGE_KVRATED_CURRENT_ACONDUCTORSHORT_CIRCUIT_KAREMARKSDESCCrossing, not connected
PRI_CROSSINGÖznitelikler
TAGVOLTAGE_KVRATED_CURRENT_ACONDUCTORSHORT_CIRCUIT_KAREMARKSDESCOverhead line
PRI_OHLÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCOverhead line, double circuit
PRI_OHL_DOUBLEÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCCable sealing end
PRI_CABLE_ENDÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCCable joint
PRI_CABLE_JOINTÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCInsulator string
PRI_INSULATORÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCTower, suspension
PRI_TOWER_SUSPÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCTower, tension (dead-end)
PRI_TOWER_TENSÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCPole, H-frame
PRI_POLE_HÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCStay wire
PRI_STAYÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCFeeder, outgoing
PRI_FEEDER_OUTÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCFeeder, incoming
PRI_FEEDER_INÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCOverhead line (IEC mark)
PRI_LINE_OH_IECÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCUnderground line
PRI_LINE_UGÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCSubmarine line
PRI_LINE_SUBÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCCable manhole (chamber)
PRI_MANHOLEÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCGas-insulated enclosure
PRI_GIS_ENCLÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCGas-insulated busbar
PRI_GIBÖznitelikler
TAGVOLTAGE_KVRATED_CURRENT_ACONDUCTORSHORT_CIRCUIT_KAREMARKSDESCCable separable connector
PRI_CABLE_SEPARABLEÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCLink box (sheath bonding)
PRI_LINK_BOXÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCOptical ground wire (OPGW)
PRI_OPGWÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCIsolated phase busduct
PRI_BUS_ISOPHASEÖznitelikler
TAGVOLTAGE_KVRATED_CURRENT_ACONDUCTORSHORT_CIRCUIT_KAREMARKSDESCOverhead line with ground wire
PRI_OHL_GROUNDWIREÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCLine in a duct
PRI_IEC_LINE_DUCTÖznitelikler
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLine in a six-way duct
PRI_IEC_LINE_SIX_WAY_DUCTÖznitelikler
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCManhole for underground line
PRI_IEC_MANHOLEÖznitelikler
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCCurrent transformer
PRI_CTÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCCurrent transformer, two cores
PRI_CT_2COREÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCCurrent transformer, three cores
PRI_CT_3COREÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCZero-sequence CT (core balance)
PRI_CT_ZEROÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCVoltage transformer
PRI_VTÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCVoltage transformer, two secondaries
PRI_VT_OPENÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCCapacitor voltage transformer
PRI_CVTÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCVoltage transformer, neutral earthed
PRI_VT_NEUTRALÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCCurrent transformer, four cores
PRI_CT_4COREÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCLow power current sensor (Rogowski)
PRI_CT_LPCTÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCVoltage transformer, star-star
PRI_VT_YYÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCVoltage transformer, star, open delta
PRI_VT_YODÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCVoltage transformer with fuse
PRI_VT_FUSEDÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCCapacitor voltage transformer, two secondaries
PRI_CVT_2SECÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCVoltage transformer, withdrawable
PRI_VT_WDÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCCT and VT, combined
PRI_ITX_COMBINEDÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCCurrent transformer, optical
PRI_CT_OPTICALÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCElectronic voltage sensor
PRI_VT_ELECTRONICÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCNeutral current transformer
PRI_CT_NEUTRALÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCReactor, series
PRI_REACTORÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCReactor, shunt
PRI_REACTOR_SHUNTÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCNeutral grounding reactor
PRI_REACTOR_NEUTRALÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCNeutral grounding resistor
PRI_NGRÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCArc suppression coil (Petersen)
PRI_PETERSENÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCLine trap (wave trap)
PRI_WAVE_TRAPÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCShunt capacitor bank
PRI_CAP_SHUNTÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCCapacitor bank, star, neutral open
PRI_CAP_SHUNT_YÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCSeries capacitor
PRI_CAP_SERIESÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCSurge arrester
PRI_ARRESTERÖznitelikler
TAGRATED_KVMCOV_KVDISCHARGE_KAHOUSINGMANUFACTURERMODELREMARKSDESCSurge arrester with counter
PRI_ARRESTER_COUNTERÖznitelikler
TAGRATED_KVMCOV_KVDISCHARGE_KAHOUSINGMANUFACTURERMODELREMARKSDESCThyristor controlled reactor (TCR)
PRI_TCRÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCThyristor switched capacitor (TSC)
PRI_TSCÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCMechanically switched capacitor (MSC)
PRI_MSCÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCMechanically switched reactor (MSR)
PRI_MSRÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCHarmonic filter, single tuned
PRI_FILTER_TUNEDÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCHarmonic filter, high pass (damped)
PRI_FILTER_HPÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCNeutral earthing resistor with CT
PRI_NGR_CTÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCEarthing transformer with resistor
PRI_EARTHING_TX_RÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCCurrent limiting reactor with bypass
PRI_CLR_BYPASSÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCCapacitor bank, double star, unbalance CT
PRI_CAP_DBL_STARÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCSeries compensation unit
PRI_FSCÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCSeries capacitor with bypass
PRI_FSC_BYPASSÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCMetal-oxide varistor (MOV)
PRI_MOVÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCSpark gap, protective
PRI_SPARK_GAPÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCSSSC, series converter
PRI_SSSCÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCFeeder bay: disconnector, breaker, CT
PRI_BAY_FEEDERÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCIncomer bay: disconnector, breaker, CT
PRI_BAY_INCOMERÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCTransformer bay: breaker and transformer
PRI_BAY_TXÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCLine bay: disconnector, breaker, CT
PRI_BAY_LINEÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCGenerator bay: breaker and generator
PRI_BAY_GENÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCBus section: disconnectors and breaker
PRI_BAY_TIEÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCRing main unit (3-way)
PRI_RMUÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCMetering cubicle: VT and CT
PRI_BAY_METERINGÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCStation auxiliary bay
PRI_BAY_SSÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCDouble busbar feeder bay
PRI_BAY_DB_FEEDERÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCDouble busbar coupler bay
PRI_BAY_DB_COUPLERÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCOne-and-a-half breaker diameter
PRI_BAY_ONE_HALFÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCCapacitor bay: breaker, reactor, bank
PRI_BAY_CAPÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCReactor bay: breaker and shunt reactor
PRI_BAY_REACTORÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCVoltage transformer bay: fuse and VT
PRI_BAY_VTÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCMotor feeder bay: contactor, fuse, motor
PRI_BAY_MOTORÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCGIS feeder bay: gas-insulated
PRI_BAY_GIS_FEEDERÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCTransformer feeder: disconnector, breaker, TX
PRI_BAY_TX_FEEDERÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCGenerator unit: transformer, GCB, generator
PRI_BAY_GEN_UNITÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCMV panel: withdrawable breaker, CT, cable
PRI_BAY_MV_PANELÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCGIS enclosure and conductor
PRI_GAI_S01391_GIS_ENCLOSURE_AND_CONDUCTORÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS compartment end, sealed
PRI_GAI_S01392_GIS_COMPARTMENT_END_SEALEDÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS compartment partition
PRI_GAI_S01393_GIS_COMPARTMENT_PARTITIONÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS partition, two chambers
PRI_GAI_S01459_GIS_PARTITION_TWO_CHAMBERSÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS support insul., inside
PRI_GAI_S01460_GIS_SUPPORT_INSUL_INSIDEÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS support insul., external
PRI_GAI_S01461_GIS_SUPPORT_INSUL_EXTERNALÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS conductor insulator
PRI_GAI_S01399_GIS_CONDUCTOR_INSULATORÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS to air-insulated bushing
PRI_GAI_S01396_GIS_TO_AIR_INSULATED_BUSHINGÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS to cable sealing end
PRI_GAI_S01397_GIS_TO_CABLE_SEALING_ENDÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS to transformer bushing
PRI_GAI_S01398_GIS_TO_TRANSFORMER_BUSHINGÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCLive connection terminal
PRI_GAI_S01836_LIVE_CONNECTION_TERMINALÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCDisconnector, earth switch
PRI_GAI_S01848_DISCONNECTOR_EARTH_SWITCHÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCDisconnecting breaker mark
PRI_GAI_S01860_DISCONNECTING_BREAKER_MARKÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCLive connectable/disconnect.
PRI_GAI_S01849_LIVE_CONNECTABLE_DISCONNECTÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCSimple voltage detector
PRI_GAI_S01843_SIMPLE_VOLTAGE_DETECTORÖznitelikler
REMARKSSTD_CLAUSESTD_REFDESCGIS breaker module
PRI_GISM_CBÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCGIS disconnector module
PRI_GISM_DSÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCGIS three-position module
PRI_GISM_DS_ESÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCGIS fast earthing module
PRI_GISM_ES_FASTÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCGIS current transformer
PRI_GISM_CTÖznitelikler
TAGRATIOCLASSBURDEN_VACORESRATED_KVMANUFACTURERMODELREMARKSDESCGIS voltage transformer
PRI_GISM_VTÖznitelikler
TAGRATIOCLASSBURDEN_VAWINDINGSRATED_KVMANUFACTURERMODELREMARKSDESCGIS surge arrester
PRI_GISM_ARRESTERÖznitelikler
TAGRATED_KVMCOV_KVDISCHARGE_KAHOUSINGMANUFACTURERMODELREMARKSDESCGIS cable end module
PRI_GISM_CABLE_ENDÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCGIS SF6-air bushing
PRI_GISM_BUSHINGÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCGIS gas compartment
PRI_GISM_DENSITYÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCGIS expansion joint
PRI_GISM_BELLOWSÖznitelikler
TAGVOLTAGE_KVRATED_CURRENT_ACONDUCTORSHORT_CIRCUIT_KAREMARKSDESCGas-insulated line (GIL)
PRI_GILÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCHGIS bay, hybrid
PRI_HGIS_BAYÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCMoulded case circuit breaker
PRI_LV_MCCBÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCMiniature circuit breaker
PRI_LV_MCBÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCResidual current device
PRI_LV_RCDÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCIsolating switch
PRI_LV_ISOLATORÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCFuse, low voltage
PRI_LV_FUSEÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCSurge protective device
PRI_LV_SPDÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCDistribution board
PRI_LV_DBÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCMain distribution board
PRI_LV_MDBÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCMotor control centre
PRI_LV_MCCÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCUPS distribution board
PRI_LV_UPSDBÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCPower factor correction
PRI_LV_PFCÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCBusduct
PRI_LV_BUSDUCTÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCCable, low voltage
PRI_LV_CABLEÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCSocket outlet
PRI_LV_SOCKETÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCBusway tap-off unit
PRI_BUSWAY_TAPÖznitelikler
TAGRATED_CURRENT_AVOLTAGEBREAKING_KATRIP_UNITPOLESMANUFACTURERMODELREMARKSDESCExcitation, static (thyristor)
PRI_EXC_STATICÖznitelikler
TAGFUNCTIONSUPPLYCOMMUNICATIONMANUFACTURERMODELREMARKSDESCExcitation, rotating (brushless)
PRI_EXC_ROTATINGÖznitelikler
TAGFUNCTIONSUPPLYCOMMUNICATIONMANUFACTURERMODELREMARKSDESCField circuit breaker (41)
PRI_FIELD_BREAKERÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCGenerator neutral earthing transformer
PRI_GEN_NEUTRAL_TXÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCSubstation, in service
PRI_IEC_STATION_SUBSTATIONÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCHydro station, planned
PRI_IEC_STATION_HYDRO_PLANNEDÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCHydro station, in service
PRI_IEC_STATION_HYDROÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCThermal station, planned
PRI_IEC_STATION_THERMAL_PLANNEDÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCThermal station, in service
PRI_IEC_STATION_THERMALÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCNuclear station, planned
PRI_IEC_STATION_NUCLEAR_PLANNEDÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCNuclear station, in service
PRI_IEC_STATION_NUCLEARÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCGeothermal station, planned
PRI_IEC_STATION_GEOTHERMAL_PLANNEDÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCGeothermal station, in service
PRI_IEC_STATION_GEOTHERMALÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSolar station, planned
PRI_IEC_STATION_SOLAR_PLANNEDÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSolar station, in service
PRI_IEC_STATION_SOLARÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCWind station, planned
PRI_IEC_STATION_WIND_PLANNEDÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCWind station, in service
PRI_IEC_STATION_WINDÖznitelikler
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCTransformer, forced cooling
PRI_TX_FORCED_COOLEDÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer, dry type
PRI_TX_DRYÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCTransformer bank, 3 x 1-ph
PRI_TX_BANK_1PHÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCShunt reactor, neutral coil
PRI_REACTOR_SHUNT_NRÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCFault current limiter
PRI_FCLÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCBraking resistor
PRI_BRAKE_RESISTORÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCSeries capacitor, TCSC
PRI_TCSCÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCSingle busbar scheme
PRI_SCH_SINGLEÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCSingle busbar, sectionalised
PRI_SCH_SECTIONÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCSingle busbar, transfer bus
PRI_SCH_BYPASSÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCDouble busbar scheme
PRI_SCH_DOUBLEÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCDouble busbar, sectionalised
PRI_SCH_DOUBLE_SECTÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCDouble busbar, 2 breakers
PRI_SCH_DOUBLE_BKRÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCRing busbar scheme
PRI_SCH_RINGÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCH scheme, line breakers
PRI_SCH_HÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCBridge scheme, TX breakers
PRI_SCH_BRIDGE_TXÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCLine-transformer unit
PRI_SCH_LINE_TXÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCDouble busbar, transfer bus
PRI_SCH_DOUBLE_TRANSFERÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCT-connection, two lines
PRI_SCH_TEEÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCBreaker-and-a-third scheme
PRI_SCH_FOUR_THIRDSÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_CIRCUIT_KABAY_NAMEMANUFACTURERMODELREMARKSDESCConverter leg (two valves)
PRI_HVDC_LEGÖznitelikler
TAGRATINGVOLTAGE_KVUNITSMANUFACTURERMODELREMARKSDESCConverter, line-commutated
PRI_HVDC_CONV_LCCÖznitelikler
TAGRATINGVOLTAGE_KVUNITSMANUFACTURERMODELREMARKSDESCConverter, voltage-sourced
PRI_HVDC_CONV_VSCÖznitelikler
TAGRATINGVOLTAGE_KVUNITSMANUFACTURERMODELREMARKSDESCConverter, 12-pulse
PRI_HVDC_CONV_12PÖznitelikler
TAGRATINGVOLTAGE_KVUNITSMANUFACTURERMODELREMARKSDESCSmoothing reactor, DC
PRI_HVDC_SMOOTHINGÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCDC filter, tuned
PRI_HVDC_DC_FILTERÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCDC line, overhead
PRI_HVDC_LINEÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCHVDC link, monopole
PRI_HVDC_MONOPOLEÖznitelikler
TAGRATINGVOLTAGE_KVUNITSMANUFACTURERMODELREMARKSDESCHVDC back-to-back station
PRI_HVDC_B2BÖznitelikler
TAGRATINGVOLTAGE_KVUNITSMANUFACTURERMODELREMARKSDESCMMC half-bridge submodule
PRI_HVDC_MMC_SMÖznitelikler
TAGRATINGVOLTAGE_KVUNITSMANUFACTURERMODELREMARKSDESCConverter transformer
PRI_HVDC_TX_CONVÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCAC filter bank, HVDC
PRI_HVDC_AC_FILTERÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCDC circuit breaker
PRI_HVDC_DC_BREAKERÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCMRTB, metallic return
PRI_HVDC_MRTBÖznitelikler
TAGRATED_KVRATED_CURRENT_ABREAKING_KAINTERRUPTERMECHANISMCONTROL_VOLTAGEMANUFACTURERMODELREMARKSDESCGround return switch (GRTS)
PRI_HVDC_GRTSÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCNeutral bus switch (NBS)
PRI_HVDC_NBSÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCCoupling capacitor, coil
PRI_COUPLING_CAPÖznitelikler
TAGRATINGRATED_KVRATED_CURRENT_ATYPEMANUFACTURERMODELREMARKSDESCPost insulator
PRI_POST_INSULATORÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCAir-break switch, on pole
PRI_AIR_BREAKÖznitelikler
TAGRATED_KVRATED_CURRENT_ASHORT_TIME_KAEARTHING_SWITCHMECHANISMMANUFACTURERMODELREMARKSDESCLine transposition
PRI_LINE_TRANSPOSEÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCLine, bundle of 2
PRI_LINE_BUNDLE_2Öznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCLine, bundle of 3
PRI_LINE_BUNDLE_3Öznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCLine, bundle of 4
PRI_LINE_BUNDLE_4Öznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCLine T-off
PRI_LINE_T_TAPÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCLine gantry, two strings
PRI_GANTRYÖznitelikler
TAGVOLTAGE_KVCONDUCTORLENGTH_KMRATED_CURRENT_ACIRCUITSFROM_TOREMARKSDESCLine surge arrester
PRI_LINE_ARRESTERÖznitelikler
TAGRATED_KVMCOV_KVDISCHARGE_KAHOUSINGMANUFACTURERMODELREMARKSDESCCable termination, outdoor
PRI_CABLE_TERM_OUTÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCCable joint, sheath break
PRI_JOINT_INSULATINGÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCCable cross-bonding section
PRI_CROSS_BONDINGÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCSheath voltage limiter
PRI_SVLÖznitelikler
TAGRATED_KVMCOV_KVDISCHARGE_KAHOUSINGMANUFACTURERMODELREMARKSDESCCables in parallel, two
PRI_CABLE_PARALLEL_2Öznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCCables in parallel, three
PRI_CABLE_PARALLEL_3Öznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCCable screen, solid bonded
PRI_CABLE_SOLID_BONDÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCCable screen, single-point
PRI_CABLE_SINGLE_BONDÖznitelikler
TAGVOLTAGE_KVCABLE_TYPELENGTH_MRATED_CURRENT_AFROM_TOREMARKSDESCNeutral isolated
PRI_NEUTRAL_ISOLATEDÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCNeutral earthed via resistor
PRI_NEUTRAL_RESISTORÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCNeutral earthed via reactor
PRI_NEUTRAL_REACTORÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESCNeutral via Petersen coil
PRI_NEUTRAL_RESONANTÖznitelikler
TAGRATING_MVAVOLTAGE_RATIOVECTOR_GROUPIMPEDANCE_PCTTAP_RANGECOOLINGNEUTRAL_EARTHINGMANUFACTURERMODELREMARKSDESC
Telif hakkı CADXChange. Sembolleri kendi çizimlerinizde ve projelerinizde, ticari olanlar dahil, serbestçe kullanıp düzenleyebilirsiniz; atıf ve bağlantı yalnızca bunları yayımladığınızda gerekir. Lütfen kütüphaneyi yeniden dağıtmayın ya da satmayın. Her ZIP'te AutoCAD 2018 biçiminde tek bir DWG dosyası ve bir README bulunur; ek bir eklenti gerekmez. Olduğu gibi, garanti verilmeden sunulur. Kütüphane koşulları (CXL-1.0)
IEC 60617 birkaç bölümden oluşur. Standardın diğer kütüphaneleri:
- Yaygın elektrik sembolleri (IEC 60617)
- Güç sistemi tek hat sembolleri (IEC 60617)
- Power system secondary equipment symbols
- Elektron tüpleri, kristaller, gecikme hatları (IEC 60617)
- Mantık kapısı sembolleri (IEC 60617)
- Flip-flop'lar, çoklayıcılar, işlemsel yükselticiler (IEC 60617)
- Telefon, seçiciler, ses ve kayıt (IEC 60617)
- Antenler, dalga kılavuzları, modülasyon, filtreler ve optik fiber (IEC 60617)
- Röleler, koruma ve anahtarlama cihazları (IEC 60617)
- Makineler, transformatörler, ölçü aletleri ve sembol elemanları (IEC 60617)
- Busbar kanalı, kablo televizyonu, havaalanı aydınlatması ve konnektörler (IEC 60617)
- Gaz yalıtımlı şalt, alarmlar ve tesisat cihazları (IEC 60617)
İlgili sembol kütüphaneleri
Bir sembol mü eksik? Hangisi olduğunu bize yazın.
Malzeme listeleri için öznitelikler
Every block has a visible tag next to the symbol (for example T1 for a transformer, QF1 for a breaker, G1 for a generator). The data of your equipment schedule are invisible attributes: RATING_MVA, VOLTAGE_KV, VECTOR_GROUP, IMPEDANCE_PCT and COOLING for transformers; RATED_KV, RATED_CURRENT_A and BREAKING_KA for switching devices; SHORT_CIRCUIT_MVA for busbars and sources; FROM_TO for lines and cables; plus MANUFACTURER, MODEL and REMARKS on most blocks.
Kütüphane nasıl kullanılır
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- The symbols are drawn at the plotted size in millimetres, mostly 15 to 30 mm long, and sit in the same size and style as the other IEC 60617 libraries, so they can share a drawing with them. Insert them at scale 1 and scale the block if your diagram needs a different size.
- Vertical devices have the connection at the top, which is the insertion point, and the other end below; busbars and busbar schemes are horizontal and centred. The busbar schemes are complete bays with breakers and disconnectors, so a substation main connection can be started from one block.
- Several items come in more than one form: transformers as circles and as windings, with and without tap changer, every common winding connection, and busbar schemes from the single busbar to the ring and the bridge. Pick the form that matches the level of detail of your drawing.
About the symbols
The electrical forms follow IEC 60617. Items that the standard does not draw as a single figure, such as busbar scheme blocks, HVDC links and cable bonding arrangements, are made from the standard's elements in the way that is usual on single-line diagrams.
The blocks are our own drawings, not copies of a standard, and the library is not certified. Check them against the legend of your project or company and change a block if yours differs.
Her sürümde neler değişti
Sürüm 1.1 · 24 Kasım 2026
42 new symbols for high-voltage work: six yard disconnector types, fast-acting and motor-driven earthing switches, breakers with closing resistors, grading capacitors or dead tank, a series compensation unit with its varistor, spark gap and bypass breaker, combined, optical and electronic instrument transformers, a converter transformer with HVDC switching and filters, a breaker-and-a-third scheme, and 13 SF6 gas-insulated modules, including a hybrid bay and a gas-insulated line.
Yeni semboller (42)
Breaker, closing resistor · Breaker, grading capacitors · Dead-tank breaker with CTs · Centre-break disconnector · Double-break disconnector · Vertical-break disconnector · Knee-type disconnector · Pantograph disconnector · Semi-pantograph disconnector · Earthing switch, fast-acting · Earthing switch, motor drive · Disconnector, motor drive · CT and VT, combined · Current transformer, optical · Electronic voltage sensor · Neutral current transformer · Series compensation unit · Series capacitor with bypass · Metal-oxide varistor (MOV) · Spark gap, protective · SSSC, series converter · GIS breaker module · GIS disconnector module · GIS three-position module · GIS fast earthing module · GIS current transformer · GIS voltage transformer · GIS surge arrester · GIS cable end module · GIS SF6-air bushing · GIS gas compartment · GIS expansion joint · Gas-insulated line (GIL) · HGIS bay, hybrid · Breaker-and-a-third scheme · Converter transformer · AC filter bank, HVDC · DC circuit breaker · MRTB, metallic return · Ground return switch (GRTS) · 2 tane daha
Sürüm 1.0 · 24 Kasım 2026
Yeni semboller (406)
Generator, synchronous · Generator, induction · Generator, DC · Hydro generator · Steam turbine generator · Gas turbine generator · Diesel generator set · PV array · Battery energy storage · Battery · Fuel cell · Grid infeed (utility source) · Inverter (DC to AC) · Rectifier (AC to DC) · HVDC converter · STATCOM · Static VAR compensator · Synchronous condenser · UPS · Battery charger · Gas engine generator set · Pumped storage motor-generator · Flywheel energy storage · Supercapacitor energy storage · Combined heat and power set · Cell · AC source · Motor, three-phase · Motor, single-phase · Generator, three-phase · Rectifier · Inverter · DC/DC converter · Frequency converter · Photovoltaic generator · Motor, slip-ring · Motor, stepper · Motor, DC, separate field · Motor, DC, shunt field · Motor, DC, series field · 366 tane daha
Sık sorulan sorular
- What is primary equipment, and what is left out?
- Primary equipment is the equipment that carries the power: generators, transformers, switchgear, busbars, lines and cables, reactors and capacitors. Relays, protection devices, meters, control switches, terminals and signalling belong to the secondary side and are left out. Current and voltage transformers are here as the bodies you draw on a single-line diagram.
- Can I draw a substation main connection with it?
- Yes. Ready-made busbar schemes (single busbar, sectionalised, with transfer bus, double busbar, ring, H and bridge), transformer and line bays, gas-insulated switchgear, instrument transformers, arresters, earthing and neutral earthing are in the library, as well as the HVDC valves and converters for a converter station.
- Can I use the symbols in commercial projects?
- Yes. You may use and modify them in your own projects, including commercial ones. They are provided as is, without warranty. Please do not redistribute or resell the library; see the library terms.
- How is this library different from the power system library?
- The power system library is a mixed one: it holds protection relays and measuring devices next to the equipment. This library holds only the primary side, with the same equipment redrawn under its own names and many additions (busbar schemes, HVDC, line equipment, cable systems and neutral earthing), so every symbol on the page is power equipment. Blocks of the same shape are named differently, so both libraries can share a drawing.
- Can I change a symbol or add attributes?
- Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
- AutoCAD için bu sembollerin hazır bir setini nereden bulabilirim?
- AutoCAD yalnızca az sayıda örnek blokla gelir; tam bir sembol seti için bir kütüphane gerekir. Bu sayfadaki ZIP'i indirip DWG dosyasını açın: her sembol bir bloktur. Bir sembolü INSERT komutuyla (Bloklar paleti, Kütüphaneler sekmesi, ardından DWG'yi seçin) ekleyebilir ya da DesignCenter'dan (ADCENTER) sürükleyebilirsiniz. Tek bir sembolü ayrı olarak da indirebilirsiniz.