KaynaklarDWG sembol kütüphaneleri
Free AutoCAD machine, transformer, meter and symbol element symbols (DWG), IEC 60617 style
Machines, transformers, meters and symbol elements (IEC 60617): 78 ready-made AutoCAD blocks (DWG), free to download and use in your own projects, as a ZIP or one symbol at a time.
78 symbols as ready-to-use AutoCAD blocks, drawn after IEC 60617 (parts 2, 6, 8): winding connection marks (one to six phases, V, T, zigzag, double delta, polygon), transformer and current transformer variants (polarity dots, variable coupling, tap, several passages, pulse transformers), heat sources and thermoelectric and thermionic generators, the closed-loop controller, instruments (recording, maximum demand, power factor, phase, synchronoscope, oscilloscope, differential voltmeter, tachometer, thermometer, combined wattmeters, watt-hour meters with maximum demand), counters and the master clock, and the symbol elements (objects, propagation and energy flow, materials, effects, radiation, magnet, analogue and digital marks). Each block stores the entry number of the standard and the database number in invisible attributes.
Version 1.0 · updated 17 Ekim 2026
Using AutoCAD 2017 or an earlier version? Download the 2010 format
Free to use and modify in your own projects, including commercial ones. The ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty.
IEC 60617 has several parts. The other libraries of the standard:
- Common electrical symbols (IEC 60617)
- Power system single-line symbols (IEC 60617)
- Electron tubes, crystals, delay lines (IEC 60617)
- Logic gate symbols (IEC 60617)
- Flip-flops, multiplexers, op amps (IEC 60617)
- Telephone, selectors, sound and recording (IEC 60617)
- Antennas, waveguides, modulation, filters and optical fibre (IEC 60617)
- Relays, protection and switching devices (IEC 60617)
- Busbar trunking, cable television, airfield lighting and connectors (IEC 60617)
- Gas-insulated switchgear, alarms and installation devices (IEC 60617)
Related symbol libraries
All 78 symbols
78 sembolün 78 tanesi

Recording instrument
MCH_S00911_RECORDING_INSTRUMENTÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Maximum demand indicator
MCH_S00915_MAXIMUM_DEMAND_INDICATORÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Power-factor meter
MCH_S00917_POWER_FACTOR_METERÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Phase meter
MCH_S00918_PHASE_METERÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Synchronoscope
MCH_S00920_SYNCHRONOSCOPEÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Oscilloscope
MCH_S00922_OSCILLOSCOPEÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Differential voltmeter
MCH_S00923_DIFFERENTIAL_VOLTMETERÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Salinity meter
MCH_S00925_SALINITY_METERÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Thermometer, pyrometer
MCH_S00926_THERMOMETER_PYROMETERÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Tachometer
MCH_S00927_TACHOMETERÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Recording watt and varmeter
MCH_S00929_RECORDING_WATT_AND_VARMETERÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Oscillograph
MCH_S00930_OSCILLOGRAPHÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Wh meter, max indicator
MCH_S00943_WH_METER_MAX_INDICATORÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Wh meter, max recorder
MCH_S00944_WH_METER_MAX_RECORDERÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Master clock
MCH_S00960_MASTER_CLOCKÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Counting function
MCH_S00946_COUNTING_FUNCTIONÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Pulse counting device
MCH_S00947_PULSE_COUNTING_DEVICEÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Counter, manually pre-set
MCH_S00948_COUNTER_MANUALLY_PRE_SETÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Counter, electrically reset
MCH_S00949_COUNTER_ELECTRICALLY_RESETÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Counter, cam driven
MCH_S00951_COUNTER_CAM_DRIVENÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC

Three separate windings
MCH_S00797_THREE_SEPARATE_WINDINGSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Six separate windings
MCH_S00798_SIX_SEPARATE_WINDINGSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Three-phase, separate
MCH_S00799_THREE_PHASE_SEPARATEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Two-phase, four-wire
MCH_S00801_TWO_PHASE_FOUR_WIREÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Two-phase winding
MCH_S00802_TWO_PHASE_WINDINGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Three-phase winding, V
MCH_S00803_THREE_PHASE_WINDING_VÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Four-phase, neutral out
MCH_S00804_FOUR_PHASE_NEUTRAL_OUTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Three-phase winding, T
MCH_S00805_THREE_PHASE_WINDING_TÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Three-phase, zigzag
MCH_S00810_THREE_PHASE_ZIGZAGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Six-phase, double delta
MCH_S00811_SIX_PHASE_DOUBLE_DELTAÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Six-phase, polygon
MCH_S00812_SIX_PHASE_POLYGONÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Transformer, polarity dots
MCH_S00843_TRANSFORMER_POLARITY_DOTSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Autotransformer, circle
MCH_S00846_AUTOTRANSFORMER_CIRCLEÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Transformer, var. coupling
MCH_S00856_TRANSFORMER_VAR_COUPLINGÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
CT, two secondary windings
MCH_S00882_CT_TWO_SECONDARY_WINDINGSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
CT, secondary with tap
MCH_S00884_CT_SECONDARY_WITH_TAPÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
CT, five primary passages
MCH_S00886_CT_FIVE_PRIMARY_PASSAGESÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Pulse CT, three conductors
MCH_S00888_PULSE_CT_THREE_CONDUCTORSÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Pulse CT, two secondaries
MCH_S00890_PULSE_CT_TWO_SECONDARIESÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC
Heat source, radio-isotope
MCH_S00901_HEAT_SOURCE_RADIO_ISOTOPEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Heat source, combustion
MCH_S00902_HEAT_SOURCE_COMBUSTIONÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Thermoelectric gen., fuel
MCH_S00903_THERMOELECTRIC_GEN_FUELÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Thermoelectric gen., light
MCH_S00904_THERMOELECTRIC_GEN_LIGHTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Thermoelectric gen., isotope
MCH_S00905_THERMOELECTRIC_GEN_ISOTOPEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Thermionic gen., radiation
MCH_S00906_THERMIONIC_GEN_RADIATIONÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Thermionic gen., isotope
MCH_S00907_THERMIONIC_GEN_ISOTOPEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Closed-loop controller
MCH_S00909_CLOSED_LOOP_CONTROLLERÖznitelikler
TAGRATINGPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESC

Object, rectangle
MCH_S00060_OBJECT_RECTANGLEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC

Protection, general
MCH_S00066_PROTECTION_GENERALÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Rotation, bidirectional
MCH_S00097_ROTATION_BIDIRECTIONALÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Propagation, one way
MCH_S00099_PROPAGATION_ONE_WAYÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Propagation, both, together
MCH_S00100_PROPAGATION_BOTH_TOGETHERÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Propagation, both, alternate
MCH_S00101_PROPAGATION_BOTH_ALTERNATEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC


Energy flow from busbars
MCH_S00104_ENERGY_FLOW_FROM_BUSBARSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Energy flow to busbars
MCH_S00105_ENERGY_FLOW_TO_BUSBARSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Energy flow, both ways
MCH_S00106_ENERGY_FLOW_BOTH_WAYSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Material, unspecified
MCH_S00113_MATERIAL_UNSPECIFIEDÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC

Material, liquid
MCH_S00115_MATERIAL_LIQUIDÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC

Material, electret
MCH_S00117_MATERIAL_ELECTRETÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Material, semiconducting
MCH_S00118_MATERIAL_SEMICONDUCTINGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Material, insulating
MCH_S00119_MATERIAL_INSULATINGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Magnetic field effect
MCH_S00123_MAGNETIC_FIELD_EFFECTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC

Semiconductor effect
MCH_S00125_SEMICONDUCTOR_EFFECTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Coupling, separation effect
MCH_S00126_COUPLING_SEPARATION_EFFECTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Radiation, non-ionizing
MCH_S00127_RADIATION_NON_IONIZINGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Radiation, bidirectional
MCH_S00130_RADIATION_BIDIRECTIONALÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Radiation, coherent, both
MCH_S00131_RADIATION_COHERENT_BOTHÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Permanent magnet
MCH_S00210_PERMANENT_MAGNETÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC

Bir sembol mü eksik? Hangisi olduğunu bize yazın.
Attributes for parts lists
Devices carry a visible reference such as P1, T1 or U1 and invisible attributes: RATING, PART_NO, MANUFACTURER and REMARKS. Marks and small figures have a remarks field only, so they can be combined freely.
Because the data sit in attributes, you can export the devices of a project to Excel with BlockSync, build a list, check it and write the corrections back in one run, with preview and backup.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- The symbols are drawn at plotted size in millimetres on a 2.5 mm grid, the grid of the standard's pages: a boxed device is about 10 to 20 mm wide, a contact about 15 mm high. Insert them at the scale of your drawing, for example scale 2 on a 1:2 drawing.
- Meters are circles or boxes centred on their figure, with a visible reference P1. Current transformers are vertical with the primary at the top, and the secondary leaves to the right with the standard's slashes. Winding marks and symbol elements are small figures centred on themselves, meant to be combined with other symbols.
- Variants share the same body and differ by a mark or a detail. Edit the mark to make a variant that is not in the library.
About IEC 60617
IEC 60617 is the international standard for graphical symbols for diagrams, in many parts. This library holds figures of parts 2, 6, 8 that are not in the library “Common electrical symbols (IEC 60617)”, drawn after the standard's database.
These symbols are our own drawings after the figures of the standard. They are not copied from it, and the library is not certified against it. Check them against the standard, your company standard or your customer’s legend before you decide to use a symbol.
Frequently asked questions
- Where are the ordinary motors, generators and transformers?
- Motors, generators, the common transformers and the star and delta winding marks are in the library “Common electrical symbols (IEC 60617)”. This library has the variants and the less common ones.
- Where are the other IEC 60617 symbols?
- The standard is spread over several libraries on this site: common electrical symbols, power system single-line, semiconductors and tubes, binary logic elements, logic functions and analogue, telephone and sound, telecom transmission, relays and protection, machines and meters, and busbar trunking with cable television. Every library page lists the others.
- Can I use the symbols in commercial projects?
- Yes. They are free to use and modify in your own projects, including commercial ones. They are provided as is, without warranty.
- What are the symbol elements for?
- Objects, materials, propagation arrows, energy-flow marks and effects are the building blocks of IEC 60617 symbols. Put them inside or next to your own symbol when you need a figure that the library does not have.
- Can I change a symbol or add attributes?
- Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
- Where do I find a ready-made set of these symbols for AutoCAD?
- AutoCAD itself ships only a small set of sample blocks, so a full symbol set has to come from a library. Download the ZIP on this page and open the DWG: every symbol is a block. Insert one with INSERT (Blocks palette, Libraries tab, then pick the DWG) or drag it from DesignCenter (ADCENTER). You can also download a single symbol on its own.
Count the symbols and build a parts list
Because ratings and part numbers are attributes, the symbols of a whole project can be counted and listed without opening the drawings. Export the blocks to Excel, total them with a pivot table and write corrections back in one run, with preview and backup.
See how to count blocks with BlockSync

