CADXChange

KaynaklarDWG sembol kütüphaneleri

Free accessibility CAD blocks for AutoCAD (DWG): ADA and Doc M toilets, wheelchair spaces, ramps, parking

Accessible design: kendi projelerinizde ücretsiz indirip kullanabileceğiniz 110 hazır AutoCAD bloğu (DWG); ZIP olarak ya da tek tek sembol olarak.

110 accessible design blocks at real size in millimetres, ready to drop into a plan: ADA wheelchair, floor-mounted and ambulatory toilet compartments and a single-user toilet room, Approved Document M 1500 x 2200 and AS 1428.1 1900 x 2300 accessible WCs in left and right hand, an ambulant cubicle and a Changing Places room; wheelchairs, scooter and rollator, clear floor spaces 760 x 1220 and 900 x 1400, turning circles 1500, 1525 and 1800, the ADA T-turn and the AS 1428.1 turning spaces, passing spaces and reach ranges; grab rails from 300 to 1065, corner, hinged and vertical rails, accessible basins, urinal and emergency pull cord; ADA transfer and roll-in showers, level-access shower, fold-down seat and bath with seat; 1:12 ramps for rises of 150 to 760, a ramp with landing, a switchback ramp, curb ramps, dropped kerb and tactile paving, platform and stair lifts, EN 81-70 lift cars; door clear widths, ADA door manoeuvring clearances, automatic doors and refuge spaces; ADA car and van spaces, AS 2890.6 and UK accessible bays, a passenger loading zone; lowered counters, desks and tables with knee space, wheelchair seating spaces and a hi-lo drinking fountain, plus the access signs that go with them.

Sürüm 1.0 · güncelleme: 16 Kasım 2026 · Nelerin değiştiğine göz atın

ZIP'i indirTarayıcıda önizle

AutoCAD 2017 veya daha eski bir sürüm mü kullanıyorsunuz? 2010 biçimini indirin

Telif hakkı CADXChange. Sembolleri kendi çizimlerinizde ve projelerinizde, ticari olanlar dahil, serbestçe kullanıp düzenleyebilirsiniz; atıf ve bağlantı yalnızca bunları yayımladığınızda gerekir. Lütfen kütüphaneyi yeniden dağıtmayın ya da satmayın. Her ZIP'te AutoCAD 2018 biçiminde tek bir DWG dosyası ve bir README bulunur; ek bir eklenti gerekmez. Olduğu gibi, garanti verilmeden sunulur. Kütüphane koşulları (CXL-1.0)

Tüm 110 sembol

110 sembolün 110 tanesi

Bir sembol mü eksik? Hangisi olduğunu bize yazın.

Malzeme listeleri için öznitelikler

Every block carries a visible tag you can number (S01 for signs, AC01 for fittings, Z01 for spaces and rooms, R01 for ramps and lifts, D01 for doors, P01 for parking bays). Fixtures hold ITEM_TYPE, SIZE, STANDARD, MOUNTING_HEIGHT_MM, MATERIAL, FINISH, MANUFACTURER, MODEL, QTY and REMARKS; spaces and layouts hold ZONE_TYPE, SIZE, STANDARD, ROOM_NO and REMARKS. STANDARD already names the guideline the block was drawn to, for example ADA 2010 604.8.1.

Export the blocks of a plan to Excel with BlockSync to list grab rails, fittings and accessible spaces with their sizes and guideline, check the count against the access statement and write corrections back in one run.

Kütüphane nasıl kullanılır

  1. Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
  2. The blocks are drawn at real size in millimetres, 1 drawing unit = 1 mm. ADA values are converted from inches: 30 in = 760, 36 in = 915, 48 in = 1220, 60 in = 1525. Insert at scale 1 in a millimetre drawing; in an inch drawing, scale by 1/25.4.
  3. Room layouts have their insertion point at the inside corner bottom-left with the entrance wall along the bottom; wall-mounted items have their back on the wall; spaces, wheelchairs and signs are centred. Left and right hand layouts are mirror images, so pick the one that matches the transfer side of your room.
  4. Clear floor spaces, turning circles and door clearances are dashed so you can lay them over furniture and check for clashes. Ramps run at 1:12 with handrails extended 305 mm at both ends and dashed landings; parking bays have hatched aisles and a floor access symbol.

About the guidelines

Accessibility rules are national. The layouts follow the dimensions of the guideline named in each block: the 2010 ADA Standards for Accessible Design in the US, Approved Document M and BS 8300 in the UK, AS 1428.1 and AS 2890.6 in Australia, EN 81-70 for lift cars. Blocks without a named guideline use common planning sizes.

The blocks are our own drawings, not copies of those documents, and the library is not certified. Rules change between editions and local codes add their own, so check every layout against the edition your project must follow before you rely on it.

Her sürümde neler değişti

Sürüm 1.0 · 16 Kasım 2026

Yeni semboller (110)

International symbol of access · Sign, accessible toilet · Sign, accessible parking · Sign, van accessible · Sign, accessible entrance · Sign, accessible route, left · Sign, accessible lift · Sign, hearing loop · Sign, refuge point · Sign, tactile and braille plate · Floor marking, access symbol · Wheelchair, manual, 700 x 1200 · Wheelchair, powered, 700 x 1300 · Mobility scooter, 650 x 1400 · Rollator walking frame · Person with long cane · Clear floor space, 760 x 1220 · Clear floor space, parallel, 1220 · Wheelchair space, 900 x 1400 · Turning circle, 1500 · Turning circle, 1525 (60 in) · Turning circle, 1800 · T-shaped turning space, 1525 · Turning space 180, 1540 x 2070 · Turning space 90, 1500 x 1500 · Passing place, 1800 x 1800 · Passing space, 1525 x 1525 · Forward reach range, elevation · Side reach range, elevation · WC compartment, ADA, wall-hung · WC compartment, ADA, floor-mounted · WC compartment, ADA, ambulatory · Toilet room, ADA, single-user · Accessible WC, Doc M, LH transfer · Accessible WC, Doc M, RH transfer · Accessible WC, AS 1428.1, LH · Accessible WC, AS 1428.1, RH · Ambulant WC cubicle, 800 wide · Changing Places, 3000 x 4000 · Grab rail, straight 300 · 70 tane daha

Sık sorulan sorular

Which accessible toilet layouts are included?
ADA wheelchair compartments with wall-hung and floor-mounted WC, an ADA ambulatory compartment and a single-user toilet room, the Approved Document M unisex WC of 1500 x 2200 and the AS 1428.1 compartment of 1900 x 2300, both in left and right hand, an ambulant cubicle of 800 width and a Changing Places room of 3000 x 4000.
What size is a wheelchair turning circle?
1500 mm is the usual value in ISO 21542 and in the UK, 1525 mm (60 in) in the ADA Standards, which also allow a T-shaped space within a 1525 square. AS 1428.1 asks for 1540 x 2070 for a 180 degree turn. All of them are in the library, drawn dashed with a wheelchair inside.
Can I use the symbols in commercial projects?
Yes. They are free to use and modify in your own projects, including commercial ones. They are provided as is, without warranty. Please do not redistribute or resell the library; see the library terms.
Can I use the ramps for any height?
The plan ramps cover rises of 150, 300, 450, 600 and 760 mm at 1:12 (760 mm is the largest rise of one ADA run). For more height use the ramp with landing or the switchback ramp, or stretch a run along its length and keep the 1:12 slope: every 100 mm of rise needs 1200 mm of ramp.
Can I change a symbol or add attributes?
Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
AutoCAD için bu sembollerin hazır bir setini nereden bulabilirim?
AutoCAD yalnızca az sayıda örnek blokla gelir; tam bir sembol seti için bir kütüphane gerekir. Bu sayfadaki ZIP'i indirip DWG dosyasını açın: her sembol bir bloktur. Bir sembolü INSERT komutuyla (Bloklar paleti, Kütüphaneler sekmesi, ardından DWG'yi seçin) ekleyebilir ya da DesignCenter'dan (ADCENTER) sürükleyebilirsiniz. Tek bir sembolü ayrı olarak da indirebilirsiniz.