CADXChange

ResourcesElectrical schematic symbols

A sliding gate operator, from the breaker to the warning lamp, in one drawing

Reversing contactors with a mechanical interlock, overload relay and brake motor, then the control circuit: emergency stop, open and close rungs with hold-in and interlock contacts, limit switches, photocell, key switch with an on-delay relay for auto-close, flashing lamp, hour meter and brake coil. All from the Pro palette.

Free to use and modify in your own projects, including commercial ones. The ZIP holds the sample drawing, a template, a plot style table and a README; no add-in needed. The data in the drawing is made up, so it is not for design or construction. Provided as is, without warranty. Library terms (CXL-1.0)

Version 1.0 · updated November 14, 2026

Free with a CADXChange account: sign in and the download starts. Up to 3 drawings a day.

This sample uses these resources

The symbols are blocks from our own libraries, with their attributes filled in. The sheet and its title block come from our ISO A3 title block template. Download them to draw your own diagrams.

What is in the ZIP

  • Sliding-Gate-Operator-Control-Sample.dwg
    Sample drawing (DWG, AutoCAD 2018 format)
  • Electrical-Template-ISO-A3.dwt
    Template (DWT) that the drawing was made on
  • CADXChange-Monochrome.ctb
    Plot style table (CTB) that prints every colour black
  • README.txt
    README with the layer list and how to use the files

The template

The electrical template has 16 layers with colours, line weights and linetypes (power circuits, busbars, control, signal, protective earth, enclosure boundaries, text and more), the text styles ISO-2.5 to ISO-5, the dimension style ISO-25 and an ISO A3 layout with a title block and revision table. The layer names are a common convention, not a standard; rename them to match your company's rules.

Layers defined

Every layer in the template with its colour, line weight and linetype, and how many objects of this sample are on it. Layers the sample does not use are still defined, ready for your own drawing.

LayerColourLine weightLinetypeUsed forObjects here
Electrical layers
ELEC-POWER10.50 mmContinuousMain power circuits28
ELEC-BUS10.70 mmContinuousBusbars and heavy linesnot used here
ELEC-CONTROL40.25 mmContinuousControl circuits43
ELEC-SIGNAL30.18 mmContinuousSignal, instrumentation and communication circuitsnot used here
ELEC-PE20.35 mmContinuousProtective earth and bonding2
ELEC-CABLE300.25 mmDASHEDCable, conduit and tray routesnot used here
SYMBOL70.25 mmContinuousSymbols (the layer the symbol libraries use)56
ELEC-TERMINAL70.25 mmContinuousTerminals and connection pointsnot used here
ELEC-BOUNDARY50.18 mmDASHDOTEnclosure, panel and device boundariesnot used here
ELEC-MECH-LINK80.18 mmDASHEDMechanical links, interlocks and measuring linksnot used here
ELEC-REF70.18 mmContinuousReference designations (-QF1, -K2)not used here
ELEC-WIRE-NO70.18 mmContinuousWire numbers and cable labels5
ELEC-XREF90.13 mmContinuousContact and cross reference textsnot used here
ELEC-TEXT70.18 mmContinuousGeneral text75
ELEC-NOTES70.18 mmContinuousNotes and legendsnot used here
ELEC-DIM30.18 mmContinuousDimensionsnot used here
Sheet and symbol layers
07defaultContinuousDefault layer, keep it emptynot used here
FRAME7defaultContinuousSheet border5
TITLEBLOCK7defaultContinuousTitle block and revision table1
VIEWPORT8defaultContinuousLayout viewport frame (does not plot)2
DRAWING-AREA8defaultContinuousBoundary of the model drawing area (does not plot)2

Styles defined

The text styles, the dimension style and the linetypes that the template defines, so you do not have to set them up in each new drawing.

KindNameSettings
Text styleISOisocp.shx, 15°, variable height
Text styleISO-2.5isocp.shx, 15°, 2.5 mm high
Text styleISO-3.5isocp.shx, 15°, 3.5 mm high
Text styleISO-5isocp.shx, 15°, 5 mm high
Text styleTB-enArial, used by the title block
Dimension styleISO-25Text 2.5 mm, arrows 2.5 mm, extension lines 1.25 mm beyond the dimension line and 0.625 mm from the object, dimension lines 3.75 mm apart, 0 decimals
LinetypeContinuousSolid line
LinetypeDASHEDDashed
LinetypeDASHDOTDash-dot
LinetypeCENTERCentre line
LinetypePHANTOMPhantom line
LinetypeHIDDENHidden line

Sheet and drawing setup

How the sheet is set up, so your own drawings print the same way.

Sheet
ISO A3 landscape, 420 × 297 mm.
Layout
One layout named ISO-A3, plotted at 1:1 on full-bleed A3 media, so the sheet has no printer margin.
Border
20 mm from the left edge (binding side) and 10 mm from the other edges; the drawing area inside is 390 × 277 mm.
Model space
Units are millimetres. The drawing area is shown at 1:1, so 1 mm in the drawing is 1 mm on paper.
Title block
160 × 79 mm at the lower right, with a four-line revision table above the company, project, title and approval fields.
Text size
2.5 mm for labels and notes, 3.5 mm and 5 mm for headings.
Linetype scale
1, so dashes are sized for plotting at 1:1.
Plot style
None set. Pick the CTB from the ZIP in the page setup for black-and-white plots.

Title block fields

The attributes of the title block.

AttributeField on the sheetValue in this sample
COMPANYCOMPANYCADXChange
PROJECTPROJECTGate Automation
AREAAREAEntrance
SYSTEMSYSTEMGate G1
CLIENTCLIENTSample
TITLEDRAWING TITLESliding gate operator, power and control
DRAWING_NODRAWING NO.E-901
CONTRACT_NOCONTRACT NO.—
REVREVA
DRAWNDRAWN—
CHECKEDCHECKED—
APPROVEDAPPROVED—
DATEDATE2026-11-15
SCALESCALENTS
SHEETSHEET1
SHEET_OFOF1

Revision table: R1 to R4, each with REV, DATE, DESCRIPTION and BY (16 attributes, empty in this sample).

Blocks in the drawing

The equipment list of the drawing: block name, symbol and how many times it is placed.

SymbolBlockPlaced
JunctionIEC_JUNCTION24
Auxiliary contact, NOIEC_AUX_CONTACT_NO4
Relay / contactor coilIEC_COIL3
Contactor, 3-poleIEC_CONTACTOR_3P2
TerminalIEC_TERMINAL2
Limit switch, NCIEC_LIMIT_NC2
Auxiliary contact, NCIEC_AUX_CONTACT_NC2
Circuit-breaker, 3-poleIEC_CIRCUIT_BREAKER_3P1
Mechanical interlockIEC_INTERLOCK_MECHANICAL1
Thermal overload relay, 3PIEC_THERMAL_RELAY_3P1
Motor with brakeIEC_MOTOR_BRAKE1
Earth (ground)IEC_EARTH1
FuseIEC_FUSE1
Emergency stop, NCIEC_ESTOP1
Thermal overload contact, NCIEC_THERMAL_CONTACT_NC1
Push-button, lit, NOIEC_PUSHBUTTON_LAMP_NO1
Push-button, NOIEC_PUSHBUTTON_NO1
Make contact, closing delayIEC_CONTACT_NO_TDC1
Proximity switch, NCIEC_PROXIMITY_NC1
Limit switch, NOIEC_LIMIT_NO1
Key switch, NOIEC_KEY_SWITCH_NO1
Coil, slow-operating relayIEC_COIL_SLOW_OPERATE1
Signal lamp, flashingIEC_LAMP_FLASHING1
Hour counterIEC_HOUR_METER1

Equipment schedule

One row per placed symbol, read from the attributes of the blocks in the drawing: what is shown on the sheet, and the schedule attributes that were filled in but are not shown.

TagDescriptionShown on the sheetFilled in, not shown
Q1Circuit-breaker, 3-poleIEC_CIRCUIT_BREAKER_3PRATING_A = C10POLES = 3CURVE = CBREAKING_KA = 10VOLTAGE = 400 V
KM1Contactor, 3-poleIEC_CONTACTOR_3PPOLES = 3UTILIZATION = AC-3COIL_VOLTAGE = 230 V AC
KM2Contactor, 3-poleIEC_CONTACTOR_3PPOLES = 3UTILIZATION = AC-3COIL_VOLTAGE = 230 V AC
F1Thermal overload relay, 3PIEC_THERMAL_RELAY_3PCLASS = 10POLES = 3
M1Motor with brakeIEC_MOTOR_BRAKEPOWER_KW = 0.55 kWVOLTAGE = 400 VCURRENT = 1.6 ABRAKE_V = 230 V ACBRAKE_NM = 6
X2TerminalIEC_TERMINALTERMINAL_NO = 1
F2FuseIEC_FUSERATING_A = 2 AVOLTAGE = 230 VCLASS = gGBREAKING_KA = 50STD_CLAUSE = 07-21-02STD_REF = S00363
SB0Emergency stop, NCIEC_ESTOPCONTACT_NO = 11-12LEGEND = E-STOPCOLOR = RedRATING_A = 10STD_CLAUSE = 07-07-06STD_REF = S00258
F1Thermal overload contact, NCIEC_THERMAL_CONTACT_NCCONTACT_NO = 95-96RATING_A = 6
X2TerminalIEC_TERMINALTERMINAL_NO = 2
S1Push-button, lit, NOIEC_PUSHBUTTON_LAMP_NOLEGEND = OPEN
KM1Auxiliary contact, NOIEC_AUX_CONTACT_NOCONTACT_NO = 13-14RATING_A = 10OPERATING_DEVICE = KM1
SQ1Limit switch, NCIEC_LIMIT_NCCONTACT_NO = 11-12RATING_A = 10ACTUATOR = Roller leverVOLTAGE = 230 V AC
KM2Auxiliary contact, NCIEC_AUX_CONTACT_NCCONTACT_NO = 21-22RATING_A = 10OPERATING_DEVICE = KM2
KM1Relay / contactor coilIEC_COILVOLTAGE = 230 V ACPOWER_W = 8
S2Push-button, NOIEC_PUSHBUTTON_NOLEGEND = CLOSECONTACT_NO = 1 NOCOLOR = GreenSTD_CLAUSE = 07-07-02STD_REF = S00254
KM2Auxiliary contact, NOIEC_AUX_CONTACT_NOCONTACT_NO = 13-14RATING_A = 10OPERATING_DEVICE = KM2
K1Make contact, closing delayIEC_CONTACT_NO_TDCCONTACT_NO = 67-68STD_CLAUSE = 07-05-01STD_REF = S00243
B3Proximity switch, NCIEC_PROXIMITY_NCCONTACT_NO = 11-12
SQ2Limit switch, NCIEC_LIMIT_NCCONTACT_NO = 11-12RATING_A = 10ACTUATOR = Roller leverVOLTAGE = 230 V AC
KM1Auxiliary contact, NCIEC_AUX_CONTACT_NCCONTACT_NO = 21-22RATING_A = 10OPERATING_DEVICE = KM1
KM2Relay / contactor coilIEC_COILVOLTAGE = 230 V ACPOWER_W = 8
SQ1Limit switch, NOIEC_LIMIT_NOCONTACT_NO = 13-14STD_CLAUSE = 07-08-01STD_REF = S00259
S3Key switch, NOIEC_KEY_SWITCH_NOCONTACT_NO = 13-14LEGEND = AUTOPOSITIONS = 2
K1Coil, slow-operating relayIEC_COIL_SLOW_OPERATEVOLTAGE = 230 V ACSTD_CLAUSE = 07-15-08STD_REF = S00312
KM1Auxiliary contact, NOIEC_AUX_CONTACT_NOCONTACT_NO = 23-24RATING_A = 10OPERATING_DEVICE = KM1
KM2Auxiliary contact, NOIEC_AUX_CONTACT_NOCONTACT_NO = 23-24RATING_A = 10OPERATING_DEVICE = KM2
H1Signal lamp, flashingIEC_LAMP_FLASHINGSTD_CLAUSE = 08-10-02STD_REF = S00966
P1Hour counterIEC_HOUR_METERSTD_CLAUSE = 08-04-01STD_REF = S00931
YB1Relay / contactor coilIEC_COILVOLTAGE = 230 V ACPOWER_W = 8

Manufacturer, model and remarks are left empty on every block, ready for your data. The values are examples.

How to use it

  1. Open the sample drawing to see how layers, text and the title block are used, or open it in the browser first, nothing to install.
  2. Start your own drawing from the template (NEW, then pick the DWT file). Copy the CTB file to your plot styles folder if you want black-and-white plots.
  3. Insert blocks from the symbol library into your drawing. The blocks in the sample are copies; they do not change when a library changes.

Frequently asked questions

Can I use the drawing for a real project?
As a starting point for layout and layers, yes. The ratings, settings and cable sizes are made up, so the diagram has to be checked and changed for your project before it is used for design or construction.
Why are the layers coloured?
Colours and line weights follow the layers: power circuits are red and heavy, control is cyan, signal is green. The plot style table in the ZIP prints everything black and keeps the line weights, so you can plot in black and white as well.
Which CAD programs open it?
The drawing and the template are in AutoCAD 2018 format, which AutoCAD 2018 and later open, and so do other CAD programs that read this format. The browser viewer needs nothing installed.