CADXChange

ResourcesPower system primary equipment symbols

110 kV GIS substation single-line diagram: sample DWG with a double busbar

A 110 kV gas-insulated substation drawn the way a power engineer reads it. Two busbars run across the sheet; every bay hangs from them through a pair of busbar disconnectors, so it can be fed from either bus. The line bays and the transformer bays each have a breaker, a current transformer, a line disconnector, a fast earthing switch and a surge arrester; the line bays leave through an air bushing, the transformer bays through a cable termination to a 63 MVA transformer. A bus coupler ties the two busbars and two voltage transformer bays sit on the ends. The sheet carries an equipment list, a bay schedule and a filled-in title block, on the same electrical template as our other power drawings.

Free to use and modify in your own projects, including commercial ones. The ZIP holds the sample drawing, a template, a plot style table and a README; no add-in needed. The data in the drawing is made up, so it is not for design or construction. Provided as is, without warranty. Library terms (CXL-1.0)

Version 1.0 · updated November 25, 2026

This sample uses these resources

The symbols are blocks from our own libraries, with their attributes filled in. The sheet and its title block come from our ISO A3 title block template. Download them to draw your own diagrams.

What is in the ZIP

  • GIS-Substation-Double-Busbar-Sample.dwg
    Sample drawing (DWG, AutoCAD 2018 format)
  • Electrical-Template-ISO-A3.dwt
    Template (DWT) that the drawing was made on
  • CADXChange-Monochrome.ctb
    Plot style table (CTB) that prints every colour black
  • README.txt
    README with the layer list and how to use the files

The template

The electrical template has 16 layers with colours, line weights and linetypes (power circuits, busbars, control, signal, protective earth, enclosure boundaries, text and more), the text styles ISO-2.5 to ISO-5, the dimension style ISO-25 and an ISO A3 layout with a title block and revision table. The layer names are a common convention, not a standard; rename them to match your company's rules.

Layers defined

Every layer in the template with its colour, line weight and linetype, and how many objects of this sample are on it. Layers the sample does not use are still defined, ready for your own drawing.

LayerColourLine weightLinetypeUsed forObjects here
Electrical layers
ELEC-POWER10.50 mmContinuousMain power circuits45
ELEC-BUS10.70 mmContinuousBusbars and heavy lines2
ELEC-CONTROL40.25 mmContinuousControl circuitsnot used here
ELEC-SIGNAL30.18 mmContinuousSignal, instrumentation and communication circuitsnot used here
ELEC-PE20.35 mmContinuousProtective earth and bondingnot used here
ELEC-CABLE300.25 mmDASHEDCable, conduit and tray routesnot used here
SYMBOL70.25 mmContinuousSymbols (the layer the symbol libraries use)42
ELEC-TERMINAL70.25 mmContinuousTerminals and connection pointsnot used here
ELEC-BOUNDARY50.18 mmDASHDOTEnclosure, panel and device boundariesnot used here
ELEC-MECH-LINK80.18 mmDASHEDMechanical links, interlocks and measuring linksnot used here
ELEC-REF70.18 mmContinuousReference designations (-QF1, -K2)not used here
ELEC-WIRE-NO70.18 mmContinuousWire numbers and cable labelsnot used here
ELEC-XREF90.13 mmContinuousContact and cross reference textsnot used here
ELEC-TEXT70.18 mmContinuousGeneral text103
ELEC-NOTES70.18 mmContinuousNotes and legends7
ELEC-DIM30.18 mmContinuousDimensionsnot used here
Sheet and symbol layers
07defaultContinuousDefault layer, keep it emptynot used here
FRAME7defaultContinuousSheet border5
TITLEBLOCK7defaultContinuousTitle block and revision table1
VIEWPORT8defaultContinuousLayout viewport frame (does not plot)2
DRAWING-AREA8defaultContinuousBoundary of the model drawing area (does not plot)2

Styles defined

The text styles, the dimension style and the linetypes that the template defines, so you do not have to set them up in each new drawing.

KindNameSettings
Text styleISOisocp.shx, 15°, variable height
Text styleISO-2.5isocp.shx, 15°, 2.5 mm high
Text styleISO-3.5isocp.shx, 15°, 3.5 mm high
Text styleISO-5isocp.shx, 15°, 5 mm high
Text styleTB-enArial, used by the title block
Dimension styleISO-25Text 2.5 mm, arrows 2.5 mm, extension lines 1.25 mm beyond the dimension line and 0.625 mm from the object, dimension lines 3.75 mm apart, 0 decimals
LinetypeContinuousSolid line
LinetypeDASHEDDashed
LinetypeDASHDOTDash-dot
LinetypeCENTERCentre line
LinetypePHANTOMPhantom line
LinetypeHIDDENHidden line

Sheet and drawing setup

How the sheet is set up, so your own drawings print the same way.

Sheet
ISO A3 landscape, 420 × 297 mm.
Layout
One layout named ISO-A3, plotted at 1:1 on full-bleed A3 media, so the sheet has no printer margin.
Border
20 mm from the left edge (binding side) and 10 mm from the other edges; the drawing area inside is 390 × 277 mm.
Model space
Units are millimetres. The drawing area is shown at 1:1, so 1 mm in the drawing is 1 mm on paper.
Title block
160 × 79 mm at the lower right, with a four-line revision table above the company, project, title and approval fields.
Text size
2.5 mm for labels and notes, 3.5 mm and 5 mm for headings.
Linetype scale
1, so dashes are sized for plotting at 1:1.
Plot style
None set. Pick the CTB from the ZIP in the page setup for black-and-white plots.

Title block fields

The attributes of the title block.

AttributeField on the sheetValue in this sample
COMPANYCOMPANYCADXChange
PROJECTPROJECT110 kV Substation
AREAAREA110 kV GIS
SYSTEMSYSTEM110 kV, 50 Hz
CLIENTCLIENTSample
TITLEDRAWING TITLEGIS single-line diagram, double busbar
DRAWING_NODRAWING NO.E-502
CONTRACT_NOCONTRACT NO.—
REVREVA
DRAWNDRAWN—
CHECKEDCHECKED—
APPROVEDAPPROVED—
DATEDATE2026-11-25
SCALESCALENTS
SHEETSHEET1
SHEET_OFOF1

Revision table: R1 to R4, each with REV, DATE, DESCRIPTION and BY (16 attributes, empty in this sample).

Blocks in the drawing

The equipment list of the drawing: block name, symbol and how many times it is placed.

SymbolBlockPlaced
GIS disconnector modulePRI_GISM_DS16
GIS breaker modulePRI_GISM_CB5
GIS current transformerPRI_GISM_CT5
GIS fast earthing modulePRI_GISM_ES_FAST4
GIS surge arresterPRI_GISM_ARRESTER4
GIS SF6-air bushingPRI_GISM_BUSHING2
GIS cable end modulePRI_GISM_CABLE_END2
Transformer with on-load tap changerPRI_TX_OLTC2
GIS voltage transformerPRI_GISM_VT2

Equipment schedule

One row per placed symbol, read from the attributes of the blocks in the drawing: what is shown on the sheet, and the schedule attributes that were filled in but are not shown.

TagDescriptionShown on the sheetFilled in, not shown
QS11GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS12GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF1GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA1GIS current transformerPRI_GISM_CTRATIO = 1200/1 ACLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS13GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QE1GIS fast earthing modulePRI_GISM_ES_FASTRATED_CURRENT_A = -SHORT_TIME_KA = 40EARTHING_SWITCH = Fast-actingMECHANISM = Spring
F1GIS surge arresterPRI_GISM_ARRESTERMCOV_KV = 84DISCHARGE_KA = 10HOUSING = Metal-enclosed
B1GIS SF6-air bushingPRI_GISM_BUSHINGCABLE_TYPE = SF6-air bushingRATED_CURRENT_A = 1250
QS21GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS22GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF2GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA2GIS current transformerPRI_GISM_CTRATIO = 1200/1 ACLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS23GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QE2GIS fast earthing modulePRI_GISM_ES_FASTRATED_CURRENT_A = -SHORT_TIME_KA = 40EARTHING_SWITCH = Fast-actingMECHANISM = Spring
F2GIS surge arresterPRI_GISM_ARRESTERMCOV_KV = 84DISCHARGE_KA = 10HOUSING = Metal-enclosed
B2GIS SF6-air bushingPRI_GISM_BUSHINGCABLE_TYPE = SF6-air bushingRATED_CURRENT_A = 1250
QS41GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS42GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF4GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA4GIS current transformerPRI_GISM_CTRATIO = 600/1 ACLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS43GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QE4GIS fast earthing modulePRI_GISM_ES_FASTRATED_CURRENT_A = -SHORT_TIME_KA = 40EARTHING_SWITCH = Fast-actingMECHANISM = Spring
F4GIS surge arresterPRI_GISM_ARRESTERMCOV_KV = 84DISCHARGE_KA = 10HOUSING = Metal-enclosed
T1Transformer with on-load tap changerPRI_TX_OLTCRATING_MVA = 63 MVAVOLTAGE_RATIO = 110/10.5 kVVECTOR_GROUP = YNd11IMPEDANCE_PCT = 12TAP_RANGE = +/-9x1.25%COOLING = ONAN/ONAFNEUTRAL_EARTHING = Solid
QS51GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS52GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF5GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA5GIS current transformerPRI_GISM_CTRATIO = 600/1 ACLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS53GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QE5GIS fast earthing modulePRI_GISM_ES_FASTRATED_CURRENT_A = -SHORT_TIME_KA = 40EARTHING_SWITCH = Fast-actingMECHANISM = Spring
F5GIS surge arresterPRI_GISM_ARRESTERMCOV_KV = 84DISCHARGE_KA = 10HOUSING = Metal-enclosed
T2Transformer with on-load tap changerPRI_TX_OLTCRATING_MVA = 63 MVAVOLTAGE_RATIO = 110/10.5 kVVECTOR_GROUP = YNd11IMPEDANCE_PCT = 12TAP_RANGE = +/-9x1.25%COOLING = ONAN/ONAFNEUTRAL_EARTHING = Solid
QS31GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QF3GIS breaker modulePRI_GISM_CBRATED_CURRENT_A = 2000BREAKING_KA = 40INTERRUPTER = SF6 self-blastMECHANISM = SpringCONTROL_VOLTAGE = 220 V DC
TA3GIS current transformerPRI_GISM_CTCLASS = 5P20 / 0.2SBURDEN_VA = 30CORES = 4RATED_KV = 126
QS32GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
QS71GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
TV1GIS voltage transformerPRI_GISM_VTCLASS = 0.2 / 3PBURDEN_VA = 50WINDINGS = 2RATED_KV = 126
QS81GIS disconnector modulePRI_GISM_DSRATED_CURRENT_A = 2000SHORT_TIME_KA = 40EARTHING_SWITCH = NoMECHANISM = Motor
TV2GIS voltage transformerPRI_GISM_VTCLASS = 0.2 / 3PBURDEN_VA = 50WINDINGS = 2RATED_KV = 126

Manufacturer, model and remarks are left empty on every block, ready for your data. The values are examples.

How to use it

  1. Open the sample drawing to see how layers, text and the title block are used, or open it in the browser first, nothing to install.
  2. Start your own drawing from the template (NEW, then pick the DWT file). Copy the CTB file to your plot styles folder if you want black-and-white plots.
  3. Insert blocks from the symbol library into your drawing. The blocks in the sample are copies; they do not change when a library changes.

Frequently asked questions

Can I use the drawing for a real project?
As a starting point for layout and layers, yes. The ratings, settings and cable sizes are made up, so the diagram has to be checked and changed for your project before it is used for design or construction.
Why are the layers coloured?
Colours and line weights follow the layers: power circuits are red and heavy, control is cyan, signal is green. The plot style table in the ZIP prints everything black and keeps the line weights, so you can plot in black and white as well.
Which CAD programs open it?
The drawing and the template are in AutoCAD 2018 format, which AutoCAD 2018 and later open, and so do other CAD programs that read this format. The browser viewer needs nothing installed.