RecursosBibliotecas de símbolos DWGCommon electrical symbols (IEC 60617)
Installation plans
Common electrical symbols (IEC 60617): Installation plans: 67 ready-made AutoCAD blocks (DWG), free to download and use in your own projects, as a ZIP or one symbol at a time.
67 blocks: power stations and substations, overhead, underground and submarine lines, wiring and installation boxes, socket outlets, switches and push-buttons, luminaires and clocks.
Version 1.2 · updated 25 de outubro de 2026 · Check out what's changed
Using AutoCAD 2017 or an earlier version? Download the 2010 format
Free to use and modify in your own projects, including commercial ones. The ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty.
Desenhos de exemplo feitos com esta biblioteca
Related symbol libraries
Electrical symbols, ANSI/IEEE 315 style79 símbolos
Power system single-line symbols (IEC 60617)178 símbolos
PLC ladder logic and I/O symbols78 símbolos
Building electrical plan symbols305 símbolos
Instrumentation symbols (ISA 5.1 style)285 símbolos
P&ID equipment and piping (ISO 10628-2 style)311 símbolos
All 67 symbols
67 de 67 símbolos
Substation, in service
IEC_STATION_SUBSTATIONAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCHydro station, planned
IEC_STATION_HYDRO_PLANNEDAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCHydro station, in service
IEC_STATION_HYDROAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCThermal station, planned
IEC_STATION_THERMAL_PLANNEDAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCThermal station, in service
IEC_STATION_THERMALAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCNuclear station, planned
IEC_STATION_NUCLEAR_PLANNEDAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCNuclear station, in service
IEC_STATION_NUCLEARAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCGeothermal station, planned
IEC_STATION_GEOTHERMAL_PLANNEDAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCGeothermal station, in service
IEC_STATION_GEOTHERMALAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSolar station, planned
IEC_STATION_SOLAR_PLANNEDAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSolar station, in service
IEC_STATION_SOLARAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCWind station, planned
IEC_STATION_WIND_PLANNEDAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCWind station, in service
IEC_STATION_WINDAtributos
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCUnderground line
IEC_LINE_UNDERGROUNDAtributos
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSubmarine line
IEC_LINE_SUBMARINEAtributos
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCOverhead line
IEC_LINE_OVERHEADAtributos
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLine in a duct
IEC_LINE_DUCTAtributos
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLine in a six-way duct
IEC_LINE_SIX_WAY_DUCTAtributos
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCManhole for underground line
IEC_MANHOLEAtributos
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCHead end with local antenna
IEC_HEAD_END_ANTENNAAtributos
DEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCDirectional coupler
IEC_DIRECTIONAL_COUPLERAtributos
DEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCBox, general symbol
IEC_BOXAtributos
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCConnection box
IEC_JUNCTION_BOXAtributos
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCConsumer's terminal
IEC_CONSUMER_TERMINALAtributos
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCDistribution centre
IEC_DISTRIBUTION_CENTREAtributos
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet
IEC_SOCKET_OUTLETAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMultiple socket outlet, 3
IEC_SOCKET_OUTLET_MULTIPLEAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMultiple socket outlet, form 2
IEC_SOCKET_OUTLET_MULTIPLE_2Atributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, protective contact
IEC_SOCKET_OUTLET_PEAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, sliding shutter
IEC_SOCKET_OUTLET_SHUTTERAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet with switch
IEC_SOCKET_OUTLET_SWITCHAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, interlocked switch
IEC_SOCKET_OUTLET_INTERLOCKAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, isolating transformer
IEC_SOCKET_OUTLET_ISOLATINGAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, telecom
IEC_SOCKET_TELECOMAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSwitch, general symbol
IEC_SWITCH_PLANAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCSwitch with pilot light
IEC_SWITCH_PILOT_LIGHTAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPeriod limiting switch
IEC_SWITCH_TIMEDAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESC2 pole switch
IEC_SWITCH_2POLEAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMultiposition switch
IEC_SWITCH_MULTIPOSITIONAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESC2 way switch
IEC_SWITCH_2WAYAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCIntermediate switch
IEC_SWITCH_INTERMEDIATEAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCDimmer
IEC_DIMMERAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPull-cord switch
IEC_SWITCH_PULL_CORDAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPush-button
IEC_PUSH_BUTTON_PLANAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPush-button with indicator lamp
IEC_PUSH_BUTTON_LAMPAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPush-button, protected
IEC_PUSH_BUTTON_PROTECTEDAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCTime switch
IEC_TIME_SWITCHAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCKey-operated switch
IEC_SWITCH_KEYAtributos
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLighting outlet position
IEC_LIGHT_OUTLETAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLighting outlet on wall
IEC_LIGHT_OUTLET_WALLAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLuminaire, fluorescent lamp
IEC_LUMINAIREAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLuminaire, several tubes
IEC_LUMINAIRE_MULTI_TUBEAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLuminaire, five tubes
IEC_LUMINAIRE_5_TUBESAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCProjector, general symbol
IEC_PROJECTORAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSpot light
IEC_SPOT_LIGHTAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCFlood light
IEC_FLOOD_LIGHTAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCEmergency luminaire, special circuit
IEC_EMERGENCY_LUMINAIREAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCEmergency luminaire, self-contained
IEC_EMERGENCY_LUMINAIRE_SELFAtributos
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCWater heater
IEC_WATER_HEATERAtributos
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCTime clock, time recorder
IEC_TIME_CLOCKAtributos
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESC
Faltou um símbolo? Diga qual.
Attributes for parts lists
Every block has a visible TAG attribute and the key parameter next to the symbol: the resistance of a resistor, the rated current of a breaker, the type of a transistor, the rated power of a motor. The other parameters (voltage, tolerance, breaking capacity, speed, frequency, contact numbers and so on) are attributes that do not show on the sheet.
Nearly all blocks also have MANUFACTURER and PART_NO, and every block has a DESC attribute holding the name of the symbol. Fill them in with the attribute editor, or export them from many drawings to Excel for a bill of materials and write the changes back with BlockSync. Many symbols also carry the entry number of IEC 60617 (STD_CLAUSE, for example 07-13-06) and the number in the standard's database (STD_REF, for example S00288) as invisible attributes, so a symbol can be found in the standard and listed in a schedule.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your drawing, or drag the blocks in from DesignCenter (ADCENTER).
- Insert a block and snap to the 5 mm grid. The insertion point is terminal 1, so the symbol lands exactly on the end of the wire.
- Fill in the tag, then double-click the block (or run EATTEDIT) to enter the rating, the type and the part number.
- To count symbols or list the attributes of many drawings, export the blocks to Excel with BlockSync and write corrected values back.
What changed in each version
Version 1.2 · 25 de outubro de 2026
Version 1.1 · 21 de outubro de 2026
The dimmer symbol now follows the IEC 60617 drawing: the switch stroke runs through the triangle.
Redrawn with more detail (1)
Dimmer