CADXChange

ResourcesPower system secondary equipment symbols

Substation communication network diagram: sample DWG of an IEC 61850 network

The communication network of a 110 kV substation automation system on one sheet. At the top, the dispatch level: an EMS, a control centre and a wide-area monitoring master on the dispatch data network, reaching the substation through a vertical encryption device and the remote gateway. In the middle, the station level: operator and engineering workstations, a data server and a protection information substation on a double station bus A and B. Below, the bay level: four protection and control IEDs, each connected to both buses, and the process level with a merging unit and a smart terminal for every bay. A GPS clock feeds an IRIG-B signal that runs through the IEDs in a chain. The sheet has a legend, a bay schedule and a device list, and uses the same electrical template as our other power drawings.

Free to use and modify in your own projects, including commercial ones. The ZIP holds the sample drawing, a template, a plot style table and a README; no add-in needed. The data in the drawing is made up, so it is not for design or construction. Provided as is, without warranty. Library terms (CXL-1.0)

Version 1.0 · updated November 25, 2026

This sample uses these resources

The symbols are blocks from our own libraries, with their attributes filled in. The sheet and its title block come from our ISO A3 title block template. Download them to draw your own diagrams.

What is in the ZIP

  • Substation-Communication-Network-Sample.dwg
    Sample drawing (DWG, AutoCAD 2018 format)
  • Electrical-Template-ISO-A3.dwt
    Template (DWT) that the drawing was made on
  • CADXChange-Monochrome.ctb
    Plot style table (CTB) that prints every colour black
  • README.txt
    README with the layer list and how to use the files

The template

The electrical template has 16 layers with colours, line weights and linetypes (power circuits, busbars, control, signal, protective earth, enclosure boundaries, text and more), the text styles ISO-2.5 to ISO-5, the dimension style ISO-25 and an ISO A3 layout with a title block and revision table. The layer names are a common convention, not a standard; rename them to match your company's rules.

Layers defined

Every layer in the template with its colour, line weight and linetype, and how many objects of this sample are on it. Layers the sample does not use are still defined, ready for your own drawing.

LayerColourLine weightLinetypeUsed forObjects here
Electrical layers
ELEC-POWER10.50 mmContinuousMain power circuitsnot used here
ELEC-BUS10.70 mmContinuousBusbars and heavy linesnot used here
ELEC-CONTROL40.25 mmContinuousControl circuitsnot used here
ELEC-SIGNAL30.18 mmContinuousSignal, instrumentation and communication circuits28
ELEC-PE20.35 mmContinuousProtective earth and bondingnot used here
ELEC-CABLE300.25 mmDASHEDCable, conduit and tray routes29
SYMBOL70.25 mmContinuousSymbols (the layer the symbol libraries use)51
ELEC-TERMINAL70.25 mmContinuousTerminals and connection pointsnot used here
ELEC-BOUNDARY50.18 mmDASHDOTEnclosure, panel and device boundariesnot used here
ELEC-MECH-LINK80.18 mmDASHEDMechanical links, interlocks and measuring linksnot used here
ELEC-REF70.18 mmContinuousReference designations (-QF1, -K2)not used here
ELEC-WIRE-NO70.18 mmContinuousWire numbers and cable labelsnot used here
ELEC-XREF90.13 mmContinuousContact and cross reference textsnot used here
ELEC-TEXT70.18 mmContinuousGeneral text121
ELEC-NOTES70.18 mmContinuousNotes and legends9
ELEC-DIM30.18 mmContinuousDimensionsnot used here
Sheet and symbol layers
07defaultContinuousDefault layer, keep it emptynot used here
FRAME7defaultContinuousSheet border5
TITLEBLOCK7defaultContinuousTitle block and revision table1
VIEWPORT8defaultContinuousLayout viewport frame (does not plot)2
DRAWING-AREA8defaultContinuousBoundary of the model drawing area (does not plot)2

Styles defined

The text styles, the dimension style and the linetypes that the template defines, so you do not have to set them up in each new drawing.

KindNameSettings
Text styleISOisocp.shx, 15°, variable height
Text styleISO-2.5isocp.shx, 15°, 2.5 mm high
Text styleISO-3.5isocp.shx, 15°, 3.5 mm high
Text styleISO-5isocp.shx, 15°, 5 mm high
Text styleTB-enArial, used by the title block
Dimension styleISO-25Text 2.5 mm, arrows 2.5 mm, extension lines 1.25 mm beyond the dimension line and 0.625 mm from the object, dimension lines 3.75 mm apart, 0 decimals
LinetypeContinuousSolid line
LinetypeDASHEDDashed
LinetypeDASHDOTDash-dot
LinetypeCENTERCentre line
LinetypePHANTOMPhantom line
LinetypeHIDDENHidden line

Sheet and drawing setup

How the sheet is set up, so your own drawings print the same way.

Sheet
ISO A3 landscape, 420 × 297 mm.
Layout
One layout named ISO-A3, plotted at 1:1 on full-bleed A3 media, so the sheet has no printer margin.
Border
20 mm from the left edge (binding side) and 10 mm from the other edges; the drawing area inside is 390 × 277 mm.
Model space
Units are millimetres. The drawing area is shown at 1:1, so 1 mm in the drawing is 1 mm on paper.
Title block
160 × 79 mm at the lower right, with a four-line revision table above the company, project, title and approval fields.
Text size
2.5 mm for labels and notes, 3.5 mm and 5 mm for headings.
Linetype scale
1, so dashes are sized for plotting at 1:1.
Plot style
None set. Pick the CTB from the ZIP in the page setup for black-and-white plots.

Title block fields

The attributes of the title block.

AttributeField on the sheetValue in this sample
COMPANYCOMPANYCADXChange
PROJECTPROJECT110 kV Substation
AREAAREASubstation automation
SYSTEMSYSTEMIEC 61850
CLIENTCLIENTSample
TITLEDRAWING TITLESubstation communication network diagram
DRAWING_NODRAWING NO.E-504
CONTRACT_NOCONTRACT NO.—
REVREVA
DRAWNDRAWN—
CHECKEDCHECKED—
APPROVEDAPPROVED—
DATEDATE2026-11-25
SCALESCALENTS
SHEETSHEET1
SHEET_OFOF1

Revision table: R1 to R4, each with REV, DATE, DESCRIPTION and BY (16 attributes, empty in this sample).

Blocks in the drawing

The equipment list of the drawing: block name, symbol and how many times it is placed.

SymbolBlockPlaced
JunctionSEC_IEC_JUNCTION21
Protection and control IEDSEC_COM_IED4
Merging unitSEC_C_MU4
Smart terminalSEC_COM_SMART_TERMINAL4
Dispatch master station (EMS / SCADA)SEC_COM_EMS1
Remote control centreSEC_COM_CONTROL_CENTRE1
Wide-area monitoring master (WAMS)SEC_COM_WAMS1
Vertical encryption deviceSEC_COM_ENCRYPTION1
Protocol gatewaySEC_C_GATEWAY1
Operator workstationSEC_COM_OWS1
Engineering workstationSEC_COM_EWS1
Data serverSEC_COM_DATA_SERVER1
Protection information substationSEC_COM_PIS1
Network A markerSEC_NET_A1
Network B markerSEC_NET_B1
Time source (GPS clock)SEC_C_GPS1
Time synchronisation extensionSEC_COM_TIME_EXT1
Station busSEC_NET_STATION_BUS1
Sampled values linkSEC_NET_SV1
GOOSE message linkSEC_COM_GOOSE1
Time synchronisation, IRIG-BSEC_NET_IRIGB1
Dispatch data network linkSEC_NET_DISPATCH1

Equipment schedule

One row per placed symbol, read from the attributes of the blocks in the drawing: what is shown on the sheet, and the schedule attributes that were filled in but are not shown.

TagDescriptionShown on the sheetFilled in, not shown
EMS1Dispatch master station (EMS / SCADA)SEC_COM_EMSFUNCTION = Dispatch EMSSUPPLY = 220 V DCCOMMUNICATION = IEC 60870-5-104
CC1Remote control centreSEC_COM_CONTROL_CENTREFUNCTION = Control centreSUPPLY = 220 V DCCOMMUNICATION = IEC 60870-5-104
WAMS1Wide-area monitoring master (WAMS)SEC_COM_WAMSFUNCTION = WAMS masterSUPPLY = 220 V DCCOMMUNICATION = IEC 60870-5-104
ENC1Vertical encryption deviceSEC_COM_ENCRYPTIONSUPPLY = 220 V DCCOMMUNICATION = IEC 60870-5-104, encrypted
RCG1Protocol gatewaySEC_C_GATEWAYSUPPLY = 220 V DCCOMMUNICATION = IEC 61850, IEC 60870-5-104
OWS1Operator workstationSEC_COM_OWSSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
EWS1Engineering workstationSEC_COM_EWSSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
DS1Data serverSEC_COM_DATA_SERVERSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
PIS1Protection information substationSEC_COM_PISSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
IED1Protection and control IEDSEC_COM_IEDSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
MU1Merging unitSEC_C_MUSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
ST1Smart terminalSEC_COM_SMART_TERMINALSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
IED2Protection and control IEDSEC_COM_IEDSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
MU2Merging unitSEC_C_MUSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
ST2Smart terminalSEC_COM_SMART_TERMINALSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
IED3Protection and control IEDSEC_COM_IEDSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
MU3Merging unitSEC_C_MUSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
ST3Smart terminalSEC_COM_SMART_TERMINALSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
IED4Protection and control IEDSEC_COM_IEDSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
MU4Merging unitSEC_C_MUSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
ST4Smart terminalSEC_COM_SMART_TERMINALSUPPLY = 220 V DCCOMMUNICATION = IEC 61850
GPS1Time source (GPS clock)SEC_C_GPSFUNCTION = GPS clockSUPPLY = 220 V DCCOMMUNICATION = IRIG-B
TSE1Time synchronisation extensionSEC_COM_TIME_EXTSUPPLY = 220 V DCCOMMUNICATION = IRIG-B

Manufacturer, model and remarks are left empty on every block, ready for your data. The values are examples.

How to use it

  1. Open the sample drawing to see how layers, text and the title block are used, or open it in the browser first, nothing to install.
  2. Start your own drawing from the template (NEW, then pick the DWT file). Copy the CTB file to your plot styles folder if you want black-and-white plots.
  3. Insert blocks from the symbol library into your drawing. The blocks in the sample are copies; they do not change when a library changes.

Frequently asked questions

Can I use the drawing for a real project?
As a starting point for layout and layers, yes. The ratings, settings and cable sizes are made up, so the diagram has to be checked and changed for your project before it is used for design or construction.
Why are the layers coloured?
Colours and line weights follow the layers: power circuits are red and heavy, control is cyan, signal is green. The plot style table in the ZIP prints everything black and keeps the line weights, so you can plot in black and white as well.
Which CAD programs open it?
The drawing and the template are in AutoCAD 2018 format, which AutoCAD 2018 and later open, and so do other CAD programs that read this format. The browser viewer needs nothing installed.