ResourcesBuilding services symbolsLighting and power plans
Boutique lighting, power, data and security, 1:75
Track spotlights, emergency lighting, sockets, till and data points, cameras and alarm, circuits to the board, a board schedule and a load summary.
Free to use and modify in your own projects, including commercial ones. The ZIP holds the sample drawing, a template, a plot style table and a README; no add-in needed. The data in the drawing is made up, so it is not for design or construction. Provided as is, without warranty. Library terms (CXL-1.0)
This sample uses these resources
The symbols are blocks from our own libraries, with their attributes filled in. The sheet and its title block come from our ISO A3 title block template. Download them to draw your own diagrams.
Title block templates (ISO A3 and more)Sheet frame and title block of this sample
Building electrical plan symbols29 of its symbols are used here
Restaurant and retail layout symbols16 of its symbols are used here
Architectural plan symbols8 of its symbols are used here
Door and window symbols4 of its symbols are used here
Drawing marks, site, services and accessibility symbols2 of its symbols are used here
Bathroom and kitchen symbols2 of its symbols are used here
Layers, styles and sheet setup are the same for every drawing in the series; they are described on the series page: Lighting and power plans
Title block fields
The attributes of the title block.
| Attribute | Field on the sheet | Value in this sample |
|---|---|---|
| COMPANY | COMPANY | CADXChange |
| PROJECT | PROJECT | Maison Linde Boutique |
| AREA | AREA | Ground floor |
| SYSTEM | SYSTEM | Electrical |
| CLIENT | CLIENT | Sample |
| TITLE | DRAWING TITLE | Boutique lighting, power, data and security |
| DRAWING_NO | DRAWING NO. | E-811 |
| CONTRACT_NO | CONTRACT NO. | — |
| REV | REV | A |
| DRAWN | DRAWN | — |
| CHECKED | CHECKED | — |
| APPROVED | APPROVED | — |
| DATE | DATE | 2026-11-01 |
| SCALE | SCALE | 1:75 |
| SHEET | SHEET | 1 |
| SHEET_OF | OF | 1 |
Revision table: R1 to R4, each with REV, DATE, DESCRIPTION and BY (16 attributes, empty in this sample).
Blocks in the drawing
The equipment list of the drawing: block name, symbol and how many times it is placed.
| Symbol | Block | Placed |
|---|---|---|
| BEP_LIGHT_SPOT | 16 | |
| BEP_SOCKET_DOUBLE | 9 | |
| BEP_EMERGENCY_LIGHT | 8 | |
| RRT_WIRE_SHELF_1830_24 | 5 | |
| BEP_LIGHT_BATTEN_TWIN | 5 | |
| ARCH_WINDOW_FIXED_2400 | 4 | |
| RRT_WALL_SHELF_2400 | 4 | |
| BEP_LIGHT_SPOT_TWIN | 4 | |
| BEP_LIGHT_WALL_WASH | 4 | |
| BEP_LIGHT_DOWNLIGHT | 4 | |
| BEP_CCTV_DOME | 4 | |
| RRT_WINDOW_DISPLAY | 3 | |
| RRT_RAIL_1800 | 3 | |
| RRT_RAIL_ROUND | 3 | |
| RRT_MANNEQUIN | 3 | |
| RRT_ROLL_CAGE | 3 | |
| BEP_LIGHT_PENDANT | 3 | |
| BEP_EXIT_SIGN | 3 | |
| BEP_SOCKET_FLOOR | 3 | |
| BEP_SOCKET_AC | 3 | |
| BEP_DETECTOR_PIR | 3 | |
| BEP_DOOR_CONTACT | 3 | |
| ARCH_DOOR_SINGLE_1000 | 2 | |
| BEP_LIGHT_CEILING | 2 | |
| BEP_OUTLET_EXTRACT_FAN | 2 | |
| BEP_SENSOR_PIR_CEILING | 2 | |
| BEP_SWITCH_THREE_GANG | 2 | |
| BEP_SWITCH_ONE_WAY | 2 | |
| BEP_FLOOR_BOX | 2 | |
| BEP_POS_POINT | 2 | |
| BEP_PRINTER_POINT | 2 | |
| BEP_OUTLET_AIR_CURTAIN | 2 | |
| BEP_OUTLET_HAND_DRYER | 2 | |
| BEP_WIFI_AP | 2 | |
| BEP_KEYPAD | 2 | |
| BEP_INTRUDER_PANEL | 2 | |
| BEP_DISTRIBUTION_BOARD | 2 | |
| BEP_METER_ELECTRIC | 2 | |
| ARCH_DOOR_DOUBLE_1500 | 1 | |
| ARCH_DOOR_SINGLE | 1 | |
| RRT_SHOE_WALL | 1 | |
| RRT_FITTING_BANK_3 | 1 | |
| RRT_MIRROR_FLOOR | 1 | |
| RRT_BENCH_1200 | 1 | |
| RRT_CASH_WRAP | 1 | |
| RRT_TABLE_DISPLAY | 1 | |
| RRT_TABLE_DISPLAY_R | 1 | |
| RRT_PLINTH | 1 | |
| RRT_DISPLAY_COUNTER | 1 | |
| ARCH_WC_ACCESSIBLE | 1 | |
| ARCH_BASIN_RECT_600 | 1 | |
| ARCH_NORTH_ARROW | 1 | |
| ARCH_SCALE_BAR | 1 |
Equipment schedule
One row per placed symbol, read from the attributes of the blocks in the drawing: what is shown on the sheet, and the schedule attributes that were filled in but are not shown.
| Tag | Description | Shown on the sheet | Filled in, not shown |
|---|---|---|---|
| A | Switch, three-gangBEP_SWITCH_THREE_GANG | CIRCUIT = L1-L3MOUNTING_HEIGHT_MM = 1200 | |
| B | Switch, one-wayBEP_SWITCH_ONE_WAY | CIRCUIT = L4MOUNTING_HEIGHT_MM = 1200 | |
| IP | Intruder alarm panelBEP_INTRUDER_PANEL | ||
| DB1 | Distribution boardBEP_DISTRIBUTION_BOARD | BOARD_NAME = DB1RATING_A = 63PHASES = 1WAYS = 24FED_FROM = MeterLOCATION = Stockroom | |
| M1 | Electricity meterBEP_METER_ELECTRIC |
Manufacturer, model and remarks are left empty on every block, ready for your data. The values are examples.
