CADXChange

ResourcesBuilding services symbols

Fire sprinkler plan: sample DWG file with pump room, sprinkler piping, detection and building services template

A complete level plan of a small office building at 1:100. A fire pump room holds the water tank, the duty pump and the jockey pump with check valves. The discharge header rises to the valve room, where the control valve, the alarm check valve, the waterflow switch, a main drain and the fire department connection are drawn. A corridor main feeds cross mains and branch lines with 28 pendant sprinklers in the office, meeting room, toilets, reception, manager's room, workroom and corridor, with an inspector's test connection at the far end. The plan also shows hose cabinets, extinguishers, smoke detectors, manual call points, sounders, exit signs, a control panel and two detection zones, with a device schedule, an equipment schedule, notes and a filled-in title block. Every symbol is a block with its attributes filled in (tag, size, rating).

Free to use and modify in your own projects, including commercial ones. The ZIP holds the sample drawing, a template, a plot style table and a README; no add-in needed. The data in the drawing is made up, so it is not for design or construction. Provided as is, without warranty. Library terms (CXL-1.0)

This sample uses these resources

The symbols are blocks from our own libraries, with their attributes filled in. The sheet and its title block come from our ISO A3 title block template. Download them to draw your own diagrams.

What is in the ZIP

  • Fire-Sprinkler-Plan-Sample.dwg
    Sample drawing (DWG, AutoCAD 2018 format)
  • BuildingServices-Fire-Template-ISO-A3.dwt
    Template (DWT) that the drawing was made on
  • CADXChange-Monochrome.ctb
    Plot style table (CTB) that prints every colour black
  • README.txt
    README with the layer list and how to use the files

The template

The fire protection template has 10 layers with colours, line weights and linetypes (building background, sprinkler mains, cross mains and branch lines, hose supply, detection zones, symbols, tags, text, notes and dimensions), the text styles ISO-2.5 to ISO-5, the dimension style ISO-25 and an ISO A3 layout with a title block and revision table. The layer names are a common convention, not a standard; rename them to match your company's rules.

Layers defined

Every layer in the template with its colour, line weight and linetype, and how many objects of this sample are on it. Layers the sample does not use are still defined, ready for your own drawing.

LayerColourLine weightLinetypeUsed forObjects here
Fire protection layers
FIRE-BG-WALL80.35 mmContinuousBuilding background: walls and partitions10
FIRE-PIPE-MAIN10.50 mmContinuousSprinkler risers and mains17
FIRE-PIPE-BRANCH10.35 mmContinuousSprinkler cross mains and branch lines34
FIRE-PIPE-HYD50.50 mmContinuousHose and standpipe supply3
FIRE-ZONE60.18 mmDASHEDDetection zone boundaries3
SYMBOL70.25 mmContinuousSymbols (the layer the symbol libraries use)68
FIRE-TAG70.18 mmContinuousEquipment, device and zone tags6
FIRE-TEXT70.18 mmContinuousGeneral text, room names, tables78
FIRE-NOTES70.18 mmContinuousNotes and legends25
FIRE-DIM30.18 mmContinuousDimensions1
Sheet and symbol layers
07defaultContinuousDefault layer, keep it emptynot used here
FRAME7defaultContinuousSheet border5
TITLEBLOCK7defaultContinuousTitle block and revision table1
VIEWPORT8defaultContinuousLayout viewport frame (does not plot)2
DRAWING-AREA8defaultContinuousBoundary of the model drawing area (does not plot)2

Styles defined

The text styles, the dimension style and the linetypes that the template defines, so you do not have to set them up in each new drawing.

KindNameSettings
Text styleISOisocp.shx, 15°, variable height
Text styleISO-2.5isocp.shx, 15°, 2.5 mm high
Text styleISO-3.5isocp.shx, 15°, 3.5 mm high
Text styleISO-5isocp.shx, 15°, 5 mm high
Text styleTB-enArial, used by the title block
Dimension styleISO-25Text 2.5 mm, arrows 2.5 mm, extension lines 1.25 mm beyond the dimension line and 0.625 mm from the object, dimension lines 3.75 mm apart, 0 decimals
LinetypeContinuousSolid line
LinetypeDASHEDDashed
LinetypeDASHDOTDash-dot
LinetypeCENTERCentre line
LinetypePHANTOMPhantom line
LinetypeHIDDENHidden line

Sheet and drawing setup

How the sheet is set up, so your own drawings print the same way.

Sheet
ISO A3 landscape, 420 × 297 mm.
Layout
One layout named ISO-A3, plotted at 1:1 on full-bleed A3 media, so the sheet has no printer margin.
Border
20 mm from the left edge (binding side) and 10 mm from the other edges; the drawing area inside is 390 × 277 mm.
Model space
Units are millimetres. The drawing area is shown at 1:1, so 1 mm in the drawing is 1 mm on paper.
Title block
160 × 79 mm at the lower right, with a four-line revision table above the company, project, title and approval fields.
Text size
2.5 mm for labels and notes, 3.5 mm and 5 mm for headings.
Linetype scale
1, so dashes are sized for plotting at 1:1.
Plot style
None set. Pick the CTB from the ZIP in the page setup for black-and-white plots.

Title block fields

The attributes of the title block. Double-click it to fill them in, or write them for a whole set of drawings with BlockSync.

AttributeField on the sheetValue in this sample
COMPANYCOMPANYCADXChange
PROJECTPROJECTOffice Building
AREAAREALevel 1
SYSTEMSYSTEMFire protection
CLIENTCLIENTSample
TITLEDRAWING TITLEFire protection plan, sprinkler system
DRAWING_NODRAWING NO.F-701
CONTRACT_NOCONTRACT NO.—
REVREVA
DRAWNDRAWN—
CHECKEDCHECKED—
APPROVEDAPPROVED—
DATEDATE2026-10-27
SCALESCALE1:100
SHEETSHEET1
SHEET_OFOF1

Revision table: R1 to R4, each with REV, DATE, DESCRIPTION and BY (16 attributes, empty in this sample).

Blocks in the drawing

The equipment list of the drawing: block name, symbol and how many times it is placed. BlockSync exports the same list from your own drawings.

SymbolBlockPlaced
Sprinkler, pendantPLF_SPR_PENDANT29
Smoke detectorPLF_DET_SMOKE7
SounderPLF_ALM_SOUNDER4
Check valve, fire servicePLF_FV_CHECK3
Fire hose cabinetPLF_HYD_CABINET3
Manual call pointPLF_DET_MCP3
Exit signPLF_ESC_EXIT3
Extinguisher, waterPLF_EXT_WATER3
Extinguisher, dry powderPLF_EXT_POWDER2
Fire water tankPLF_FTANK_WATER1
Fire pump, electricPLF_FPUMP_ELEC1
Jockey pumpPLF_FPUMP_JOCKEY1
Gate valve, OS&YPLF_FV_OSY1
Alarm check valve (wet)PLF_FV_ALARM1
Waterflow switchPLF_SW_FLOW1
Test and drain valvePLF_FV_TEST1
Siamese connection (FDC)PLF_FV_SIAMESE1
Inspector's test connectionPLF_FV_ITC1
Fire alarm control panelPLF_ALM_PANEL1
Extinguisher, CO2PLF_EXT_CO21

Equipment schedule

One row per placed symbol, read from the attributes of the blocks in the drawing: what is shown on the sheet, and the schedule attributes that were filled in but are not shown. BlockSync exports these same attributes from your own drawings.

TagDescriptionShown on the sheetFilled in, not shown
FWT-1Fire water tankPLF_FTANK_WATERSERVICE = Fire waterCAPACITY = 18 m3FLOW_M3H = 30PRESSURE_BAR = 0VOLTAGE = 400 V
FP-1Fire pump, electricPLF_FPUMP_ELECSERVICE = Sprinkler duty pumpFLOW_M3H = 30HEAD_M = 60MOTOR_KW = 11VOLTAGE = 400 VSPEED_CONTROL = Fixed
JP-1Jockey pumpPLF_FPUMP_JOCKEYSERVICE = Pressure maintenanceFLOW_M3H = 3HEAD_M = 65MOTOR_KW = 1.5VOLTAGE = 400 VSPEED_CONTROL = Fixed
CV-1Check valve, fire servicePLF_FV_CHECKSIZE = DN80VALVE_TYPE = Swing check valvePRESSURE_RATING = PN16SUPERVISED = NoEND_CONNECTION = FlangedZONE = Level 1
CV-2Check valve, fire servicePLF_FV_CHECKSIZE = DN32VALVE_TYPE = Swing check valvePRESSURE_RATING = PN16SUPERVISED = NoEND_CONNECTION = FlangedZONE = Level 1
OSY-1Gate valve, OS&YPLF_FV_OSYSIZE = DN100VALVE_TYPE = OS&Y gate valvePRESSURE_RATING = PN16SUPERVISED = YesEND_CONNECTION = FlangedZONE = Level 1
AV-1Alarm check valve (wet)PLF_FV_ALARMSIZE = DN100VALVE_TYPE = Wet alarm check valvePRESSURE_RATING = PN16SUPERVISED = YesEND_CONNECTION = FlangedZONE = Level 1
FS-1Waterflow switchPLF_SW_FLOWSIZE = DN100VALVE_TYPE = Vane typePRESSURE_RATING = PN16SUPERVISED = YesEND_CONNECTION = FlangedZONE = Level 1
TD-1Test and drain valvePLF_FV_TESTSIZE = DN50VALVE_TYPE = Ball valvePRESSURE_RATING = PN16SUPERVISED = NoEND_CONNECTION = FlangedZONE = Level 1
FDC-1Siamese connection (FDC)PLF_FV_SIAMESESIZE = DN100VALVE_TYPE = Two-way inletPRESSURE_RATING = PN16SUPERVISED = NoEND_CONNECTION = FlangedZONE = Level 1
CV-3Check valve, fire servicePLF_FV_CHECKSIZE = DN100VALVE_TYPE = Swing check valvePRESSURE_RATING = PN16SUPERVISED = NoEND_CONNECTION = FlangedZONE = Level 1
ITC-1Inspector's test connectionPLF_FV_ITCSIZE = DN25VALVE_TYPE = Ball valvePRESSURE_RATING = PN16SUPERVISED = NoEND_CONNECTION = FlangedZONE = Level 1
HC-1Fire hose cabinetPLF_HYD_CABINETTYPE = Hose reel cabinetOUTLET_SIZE = DN25FLOW_LPM = 30PRESSURE_BAR = 4LOCATION = CorridorZONE = Level 1
HC-2Fire hose cabinetPLF_HYD_CABINETTYPE = Hose reel cabinetOUTLET_SIZE = DN25FLOW_LPM = 30PRESSURE_BAR = 4LOCATION = CorridorZONE = Level 1
FACPFire alarm control panelPLF_ALM_PANELADDRESS = PanelLOOP_ZONE = Z1-Z2LOCATION = ReceptionDEVICE_TYPE = Control panelVOLTAGE = 400 V
SD-1Smoke detectorPLF_DET_SMOKEADDRESS = L1-01LOOP_ZONE = Z1LOCATION = Open officeDEVICE_TYPE = Optical smokeVOLTAGE = 400 V
SD-2Smoke detectorPLF_DET_SMOKEADDRESS = L1-02LOOP_ZONE = Z1LOCATION = Open officeDEVICE_TYPE = Optical smokeVOLTAGE = 400 V
SD-3Smoke detectorPLF_DET_SMOKEADDRESS = L1-03LOOP_ZONE = Z1LOCATION = Meeting roomDEVICE_TYPE = Optical smokeVOLTAGE = 400 V
SD-4Smoke detectorPLF_DET_SMOKEADDRESS = L1-04LOOP_ZONE = Z2LOCATION = ManagerDEVICE_TYPE = Optical smokeVOLTAGE = 400 V
SD-5Smoke detectorPLF_DET_SMOKEADDRESS = L1-05LOOP_ZONE = Z2LOCATION = WorkroomDEVICE_TYPE = Optical smokeVOLTAGE = 400 V
SD-6Smoke detectorPLF_DET_SMOKEADDRESS = L1-06LOOP_ZONE = Z2LOCATION = WorkroomDEVICE_TYPE = Optical smokeVOLTAGE = 400 V
MCP-1Manual call pointPLF_DET_MCPADDRESS = L1-07LOOP_ZONE = Z2LOCATION = East exitDEVICE_TYPE = Manual call pointVOLTAGE = 400 V
MCP-2Manual call pointPLF_DET_MCPADDRESS = L1-08LOOP_ZONE = Z2LOCATION = ReceptionDEVICE_TYPE = Manual call pointVOLTAGE = 400 V
SN-1SounderPLF_ALM_SOUNDERADDRESS = L1-09LOOP_ZONE = Z1LOCATION = Open officeDEVICE_TYPE = SounderVOLTAGE = 400 V
SN-2SounderPLF_ALM_SOUNDERADDRESS = L1-10LOOP_ZONE = Z1LOCATION = Meeting roomDEVICE_TYPE = SounderVOLTAGE = 400 V
SN-3SounderPLF_ALM_SOUNDERADDRESS = L1-11LOOP_ZONE = Z2LOCATION = WorkroomDEVICE_TYPE = SounderVOLTAGE = 400 V
EX-1Exit signPLF_ESC_EXITLOCATION = East exitMOUNTING = WallBATTERY_DURATION = 3 h
EX-2Exit signPLF_ESC_EXITLOCATION = ReceptionMOUNTING = WallBATTERY_DURATION = 3 h
FE-1Extinguisher, waterPLF_EXT_WATERMOUNTING = Wall bracketLOCATION = Open officeNEXT_SERVICE = 2027-10
FE-2Extinguisher, waterPLF_EXT_WATERMOUNTING = Wall bracketLOCATION = Meeting roomNEXT_SERVICE = 2027-10
FE-3Extinguisher, dry powderPLF_EXT_POWDERMOUNTING = Wall bracketLOCATION = Fire pump roomNEXT_SERVICE = 2027-10
FE-4Extinguisher, CO2PLF_EXT_CO2MOUNTING = Wall bracketLOCATION = ReceptionNEXT_SERVICE = 2027-10
FE-5Extinguisher, dry powderPLF_EXT_POWDERMOUNTING = Wall bracketLOCATION = WorkroomNEXT_SERVICE = 2027-10

Manufacturer, model and remarks are left empty on every block, ready for your data. The values are examples.

Works with these resources

How to use it

  1. Open the sample drawing to see how layers, text and the title block are used, or open it in the browser first, nothing to install.
  2. Start your own drawing from the template (NEW, then pick the DWT file). Copy the CTB file to your plot styles folder if you want black-and-white plots.
  3. Insert blocks from the symbol library into your drawing. The blocks in the sample are copies; they do not change when a library changes.
  4. Double-click the title block to fill it in, then export the equipment list with BlockSync.

Frequently asked questions

Can I use the drawing for a real project?
As a starting point for layout and layers, yes. The ratings, settings and cable sizes are made up, so the diagram has to be checked and changed for your project before it is used for design or construction.
Why are the layers coloured?
Colours and line weights follow the layers: power circuits are red and heavy, control is cyan, signal is green. The plot style table in the ZIP prints everything black and keeps the line weights, so you can plot in black and white as well.
Which CAD programs open it?
The drawing and the template are in AutoCAD 2018 format, which AutoCAD 2018 and later open, and so do other CAD programs that read this format. The browser viewer needs nothing installed.