Free AutoCAD plumbing and fire protection symbols (DWG): pipes, drains, sprinklers, alarms

Plumbing and fire protection symbols: 260 ready-made AutoCAD blocks (DWG), free to download and use in your own projects, as a ZIP or one symbol at a time.

260 plumbing, drainage and fire protection symbols as ready-to-use AutoCAD blocks for plans, riser diagrams and schematics: pipe fittings and supports, plumbing valves and backflow preventers, floor drains, cleanouts and manholes, water heaters and pumps, pipe service lines, sprinklers and nozzles, alarm check and deluge valves, hydrants and hose reels, extinguishers, fire pumps, smoke and heat detectors, call points, sounders, alarm panels, escape symbols, gas, water mist, foam and drencher suppression with monitors, and smoke control and compartment symbols (smoke curtains, fire walls, shutters, smoke fans, fire lifts, control rooms). Each block carries a tag and invisible schedule attributes.

Version 1.1 · updated October 23, 2026 · Check out what's changed

Using AutoCAD 2017 or an earlier version? Download the 2010 format

Copyright CADXChange. Use and modify the symbols freely in your own drawings and projects, including commercial ones; credit and a link are needed only when you publish them. Please do not redistribute or resell the library. Each ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty. Library terms (CXL-1.0)

All 260 symbols

260 of 260 symbols

Missing a symbol? Tell us which one.

Attributes for parts lists

Every block has a visible tag next to the symbol (for example FD-1 for a floor drain, SP-12 for a sprinkler, MCP-3 for a manual call point). The data you put on a schedule are invisible attributes: SIZE, VALVE_TYPE and PRESSURE_RATING for valves; K_FACTOR, TEMP_RATING and RESPONSE for sprinklers; ADDRESS, LOOP_ZONE and LOCATION for detectors and alarm devices; AGENT, RATING and CAPACITY for extinguishers; FLOW_M3H and HEAD_M for pumps.

How to use the library

  1. Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
  2. The symbols are drawn at the plotted size in millimetres (text 2 mm). Insert them at the plot scale of your drawing, for example scale 100 on a 1:100 plan, and they print at the size they are drawn.
  3. Pipe and valve symbols lie on a horizontal pipe centre line with short stubs: insert one on a pipe and rotate it to the direction of the pipe. Plan symbols such as drains, sprinklers, detectors and hydrants are centred on the insertion point.
  4. The pipe service blocks are line samples with the service code in the middle (CW, HW, SAN, FS and others). Solid, dashed and dotted lines separate supply, drainage and vent services; replace the code to match the legend of your project.

About the conventions

Plumbing and fire protection symbols are not fixed by a single standard: practice differs by country, discipline and office. Related standards are NFPA 170 for fire safety symbols and ISO 6412 for the simplified representation of pipelines, and most offices keep their own legend.

The blocks are our own drawings after common drafting conventions, not copies of a standard, and the library is not certified. Check the symbols against the legend of your project or the requirements of the authority, and change a block if yours differs.

What changed in each version

Version 1.1 · October 23, 2026

New: gas suppression (cylinder bank, release panel, discharge warning light), water mist, foam and drencher equipment, fire water and foam monitors, flow test header, kitchen hood suppression, smoke curtains, fire wall and smoke barrier lines, fire shutter, smoke extract and pressurisation fans, fire-fighting lift, fire control room, fire service access point, area of refuge, fire stopping, in-rack sprinkler, zone control valve, fire pump controller, fixed-temperature heat detector, remote indicator lamp, power supply, sprinkler control panel and firefighter's switch.

New symbols (31)

Sprinkler, in-rack · Zone control valve assembly · Fire pump controller · Heat detector, fixed temp. · Remote indicator lamp · Fire alarm power supply · Sprinkler control panel · Firefighter's switch · Gas cylinder bank · Gas release panel · Gas discharge warning light · Water mist pump unit · Section valve, mist/deluge · Kitchen hood suppression · Foam proportioner · Fire water monitor · Foam monitor · Drencher line, water curtain · Flow test header · Smoke curtain, fixed · Smoke curtain, drop-down · Fire wall line · Smoke barrier line · Fire shutter · Smoke extract fan · Stair pressurisation fan · Fire-fighting lift · Fire control room · Fire service access point · Area of refuge · Fire stopping, penetration

Frequently asked questions

Do the symbols follow NFPA 170 or a national standard?
They follow common drafting conventions, so most of them will look familiar, but the library is not a certified implementation of NFPA 170 or of a national standard. Compare them with the legend your project or authority requires and change a block where it differs.
Can I use the blocks for a sprinkler schedule or a device list?
Yes. The sprinkler blocks have K-factor, temperature rating, response and coverage attributes, and the detector and alarm blocks have address, loop and location.
Can I use the symbols in commercial projects?
Yes. They are free to use and modify in your own projects, including commercial ones. They are provided as is, without warranty. Please do not redistribute or resell the library; see the library terms.
Are toilets, basins and other fixtures included?
No, this library covers the piping, valves, drainage, equipment and fire protection. The sanitary fixtures in plan and elevation are in the architectural plan symbol library, so use both libraries together on a plumbing plan.
Can I change a symbol or add attributes?
Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
What is the difference between an upright, a pendent and a sidewall sprinkler?
An upright sprinkler stands on top of the pipe and sprays upward onto its deflector, a pendent sprinkler hangs below the pipe and sprays downward, and a sidewall sprinkler is fixed to a wall and throws the water out into the room. The library has blocks for the upright, the dry pendent and the sidewall sprinkler, so the plan shows which type goes where.
What is the K-factor of a sprinkler and where do I put it?
The K-factor tells how much water a sprinkler discharges at a given pressure: flow = K × √pressure, in gpm and psi (K 5.6 is the standard 1/2 inch orifice). The sprinkler blocks have a K-factor attribute, so the value is stored in the block and can be listed in a sprinkler schedule.
Where do I find a ready-made set of these symbols for AutoCAD?
AutoCAD itself ships only a small set of sample blocks, so a full symbol set has to come from a library. Download the ZIP on this page and open the DWG: every symbol is a block. Insert one with INSERT (Blocks palette, Libraries tab, then pick the DWG) or drag it from DesignCenter (ADCENTER). You can also download a single symbol on its own.