CADXChange

ResourcesPower system secondary equipment symbols

110 kV line bay secondary circuits: sample DWGs of DC control schematics

Two sheets of the secondary circuits of one 110 kV line bay on a 220 V DC supply, drawn as vertical current paths between the +KM and -KM rails. The first shows the trip and close circuits of the circuit-breaker: close circuit with anti-pumping, two independent trip circuits, a supervision relay and position lamps. The second is the control circuit schematic: the control supply breaker, spring charging motor and cabinet light, disconnector close and open with a local or remote selector and interlocks on the breaker and earthing switch, and the SF6 gas alarm and lockout. Each sheet has a device list and a table of functions and current paths. Both use the same electrical template as our other power drawings.

Free to use and modify in your own projects, including commercial ones. The ZIP holds the sample drawing, a template, a plot style table and a README; no add-in needed. The data in the drawing is made up, so it is not for design or construction. Provided as is, without warranty. Library terms (CXL-1.0)

This sample uses these resources

The symbols are blocks from our own libraries, with their attributes filled in. The sheet and its title block come from our ISO A3 title block template. Download them to draw your own diagrams.

What is in the ZIP

  • Line-Bay-Trip-Close-Sample.dwg
    Sample drawing (DWG, AutoCAD 2018 format)
  • Line-Bay-Control-Circuit-Sample.dwg
    Sample drawing (DWG, AutoCAD 2018 format)
  • Electrical-Template-ISO-A3.dwt
    Template (DWT) that the drawing was made on
  • CADXChange-Monochrome.ctb
    Plot style table (CTB) that prints every colour black
  • README.txt
    README with the layer list and how to use the files

Every ZIP holds its own drawing together with the template, the plot style table and the README.

The template

The electrical template has 16 layers with colours, line weights and linetypes (power circuits, busbars, control, signal, protective earth, enclosure boundaries, text and more), the text styles ISO-2.5 to ISO-5, the dimension style ISO-25 and an ISO A3 layout with a title block and revision table. The layer names are a common convention, not a standard; rename them to match your company's rules.

Layers defined

Every layer in the template with its colour, line weight and linetype, and how many objects of this sample are on it. Layers the sample does not use are still defined, ready for your own drawing.

LayerColourLine weightLinetypeUsed forTrip and close circuitsControl circuit schematic
Electrical layers
ELEC-POWER10.50 mmContinuousMain power circuitsnot used herenot used here
ELEC-BUS10.70 mmContinuousBusbars and heavy linesnot used herenot used here
ELEC-CONTROL40.25 mmContinuousControl circuits3142
ELEC-SIGNAL30.18 mmContinuousSignal, instrumentation and communication circuitsnot used herenot used here
ELEC-PE20.35 mmContinuousProtective earth and bondingnot used herenot used here
ELEC-CABLE300.25 mmDASHEDCable, conduit and tray routesnot used herenot used here
SYMBOL70.25 mmContinuousSymbols (the layer the symbol libraries use)3746
ELEC-TERMINAL70.25 mmContinuousTerminals and connection pointsnot used herenot used here
ELEC-BOUNDARY50.18 mmDASHDOTEnclosure, panel and device boundaries2not used here
ELEC-MECH-LINK80.18 mmDASHEDMechanical links, interlocks and measuring linksnot used herenot used here
ELEC-REF70.18 mmContinuousReference designations (-QF1, -K2)not used herenot used here
ELEC-WIRE-NO70.18 mmContinuousWire numbers and cable labels22
ELEC-XREF90.13 mmContinuousContact and cross reference textsnot used herenot used here
ELEC-TEXT70.18 mmContinuousGeneral text110142
ELEC-NOTES70.18 mmContinuousNotes and legends67
ELEC-DIM30.18 mmContinuousDimensionsnot used herenot used here
Sheet and symbol layers
07defaultContinuousDefault layer, keep it emptynot used herenot used here
FRAME7defaultContinuousSheet border55
TITLEBLOCK7defaultContinuousTitle block and revision table11
VIEWPORT8defaultContinuousLayout viewport frame (does not plot)22
DRAWING-AREA8defaultContinuousBoundary of the model drawing area (does not plot)22

Styles defined

The text styles, the dimension style and the linetypes that the template defines, so you do not have to set them up in each new drawing.

KindNameSettings
Text styleISOisocp.shx, 15°, variable height
Text styleISO-2.5isocp.shx, 15°, 2.5 mm high
Text styleISO-3.5isocp.shx, 15°, 3.5 mm high
Text styleISO-5isocp.shx, 15°, 5 mm high
Text styleTB-enArial, used by the title block
Dimension styleISO-25Text 2.5 mm, arrows 2.5 mm, extension lines 1.25 mm beyond the dimension line and 0.625 mm from the object, dimension lines 3.75 mm apart, 0 decimals
LinetypeContinuousSolid line
LinetypeDASHEDDashed
LinetypeDASHDOTDash-dot
LinetypeCENTERCentre line
LinetypePHANTOMPhantom line
LinetypeHIDDENHidden line

Sheet and drawing setup

How the sheet is set up, so your own drawings print the same way.

Sheet
ISO A3 landscape, 420 × 297 mm.
Layout
One layout named ISO-A3, plotted at 1:1 on full-bleed A3 media, so the sheet has no printer margin.
Border
20 mm from the left edge (binding side) and 10 mm from the other edges; the drawing area inside is 390 × 277 mm.
Model space
Units are millimetres. The drawing area is shown at 1:1, so 1 mm in the drawing is 1 mm on paper.
Title block
160 × 79 mm at the lower right, with a four-line revision table above the company, project, title and approval fields.
Text size
2.5 mm for labels and notes, 3.5 mm and 5 mm for headings.
Linetype scale
1, so dashes are sized for plotting at 1:1.
Plot style
None set. Pick the CTB from the ZIP in the page setup for black-and-white plots.

How to use it

  1. Open the sample drawing to see how layers, text and the title block are used, or open it in the browser first, nothing to install.
  2. Start your own drawing from the template (NEW, then pick the DWT file). Copy the CTB file to your plot styles folder if you want black-and-white plots.
  3. Insert blocks from the symbol library into your drawing. The blocks in the sample are copies; they do not change when a library changes.

Frequently asked questions

Can I use the drawing for a real project?
As a starting point for layout and layers, yes. The ratings, settings and cable sizes are made up, so the diagram has to be checked and changed for your project before it is used for design or construction.
Why are the layers coloured?
Colours and line weights follow the layers: power circuits are red and heavy, control is cyan, signal is green. The plot style table in the ZIP prints everything black and keeps the line weights, so you can plot in black and white as well.
Which CAD programs open it?
The drawing and the template are in AutoCAD 2018 format, which AutoCAD 2018 and later open, and so do other CAD programs that read this format. The browser viewer needs nothing installed.