Topics:Instrumentation and control symbols
Free PLC ladder logic symbols for AutoCAD (DWG): contacts, coils, timers, counters, I/O modules (IEC 61131-3)
PLC ladder logic and I/O symbols (IEC 61131-3): 78 ready-made AutoCAD blocks (DWG). A starter pack of 24 symbols is free; the Standard edition is $19.
Free starter pack: 24 symbols
The most-used symbols of this library, as AutoCAD blocks in one DWG. Free for everyone, for any project.
Contact, normally open
Power rail, left
TON, on-delay timer
CPU module
Proximity sensor, 3-wire PNP to input
I/O address tag
Contact, normally closed
Power rail, right
TOF, off-delay timer
Power supply module, 24 VDC
Proximity sensor, 3-wire NPN to input
Rung number tag
Contact, rising edge (P)
Rung wire, 20 mm
TP, pulse timer
Digital input module, 8 channels
Photoelectric sensor, 3-wire PNP, to input
Cross reference tag
Contact, falling edge (N)
Parallel branch, start
CTU, up counter
Digital input module, 16 channels
Normally open contact to input
Terminal strip, eight terminals
Standard: 78 symbols
All 78 symbols of the Standard edition in one download, ready to insert in AutoCAD. Pay once and keep the files.
Free starter pack
$0For everyone, for any project
- 24 symbols
- No sign-in
- One DWG
Library licence
$19
For one person
Education: free
- Pay once
Student or teacher?
Free for one year with your school e-mail address. Renew it with the same address.
Sign in with your school e-mail address, we check it, and the licence is added to your account.
Available soonEducation licences are for study and teaching, valid for one year, and renewed with your school e-mail address.
What each version contains
The symbols by group, and how many of each group every version holds.
| Content | Free | Standard |
|---|---|---|
| All symbols | 24 | 78 |
| Added by this version | β | +54 |
| Ladder contacts and coils | 4 | 12 |
| Ladder rails and rungs | 4 | 9 |
| Ladder function blocks | 4 | 21 |
| PLC modules and racks | 4 | 16 |
| Field wiring to PLC I/O | 4 | 16 |
| I/O and rung tags | 4 | 4 |
The free pack is a hand-picked selection. Standard is one purchase and gives you every symbol as DWG files.
78 PLC symbols as ready-to-use AutoCAD blocks: ladder contacts and coils (normally open and closed, rising and falling edge, set and reset), power rails and rung examples, the standard function blocks (TON, TOF, TP, CTU, CTD, CTUD, edge detectors, bistables, comparison and arithmetic), PLC rack, power supply, CPU and I/O modules (digital, analog, RTD, thermocouple, high-speed counter, communication), and typical field wiring: 3-wire PNP and NPN sensors, switches, lamps, coils, solenoids, 2-wire and 4-wire 4-20 mA transmitters, RTD, thermocouple, 0-10 V and encoders. Variables, addresses, slots and tags are attributes, so I/O lists can be read straight from the drawings.
Version 1.0 Β· updated October 17, 2026
Sample drawings made with this library
All 78 symbols
78 of 78 symbols
CPU module
PLC_MOD_CPUAttributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCDigital input module, 8 channels
PLC_MOD_DI8Attributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCDigital input module, 16 channels
PLC_MOD_DI16Attributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCDigital output module, 8 relay outputs
PLC_MOD_DO8_RELAYAttributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCDigital output module, 8 transistor outputs
PLC_MOD_DO8_TRANSISTORAttributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCDigital output module, 16 channels
PLC_MOD_DO16Attributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCAnalog input module, 4 channels (4-20 mA / 0-10 V)
PLC_MOD_AI4Attributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCAnalog input module, 8 channels
PLC_MOD_AI8Attributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCAnalog output module, 4 channels
PLC_MOD_AO4Attributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCRTD input module, 4 channels (Pt100)
PLC_MOD_RTD4Attributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCThermocouple input module, 4 channels
PLC_MOD_TC4Attributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCHigh-speed counter module, 2 channels
PLC_MOD_HSCAttributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCCommunication module, Ethernet
PLC_MOD_COMM_ETHAttributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCCommunication module, serial RS-485
PLC_MOD_COMM_SERIALAttributes
SLOTMODULE_TYPEADDRESS_STARTCHANNELSSIGNALPART_NOMANUFACTURERREMARKSDESCProximity sensor, 3-wire PNP to input
PLC_FIELD_PROX_PNPAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCProximity sensor, 3-wire NPN to input
PLC_FIELD_PROX_NPNAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCPhotoelectric sensor, 3-wire PNP, to input
PLC_FIELD_PHOTO_PNPAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCNormally open contact to input
PLC_FIELD_CONTACT_NOAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCNormally closed contact to input
PLC_FIELD_CONTACT_NCAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCPushbutton (normally open) to input
PLC_FIELD_PUSHBUTTONAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCEmergency stop (normally closed) to input
PLC_FIELD_ESTOPAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCPilot lamp from output
PLC_FIELD_LAMPAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCRelay or contactor coil from output
PLC_FIELD_COILAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCSolenoid valve from output
PLC_FIELD_SOLENOIDAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCTransmitter, 2-wire 4-20 mA loop to analog input
PLC_FIELD_4_20MA_2WIREAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCTransmitter, 4-wire 4-20 mA output to analog input
PLC_FIELD_4_20MA_4WIREAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCRTD (Pt100), 3-wire, to RTD input
PLC_FIELD_RTD_3WIREAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCThermocouple to thermocouple input
PLC_FIELD_THERMOCOUPLEAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCSensor with 0-10 V output to analog input
PLC_FIELD_0_10VAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESCIncremental encoder A, B, Z to counter input
PLC_FIELD_ENCODERAttributes
TAGADDRESSDESCRIPTIONCABLEPART_NOMANUFACTURERREMARKSDESC
Copyright CADXChange. Use and modify the symbols freely in your own drawings and projects, including commercial ones; credit and a link are needed only when you publish them. Please do not redistribute or resell the library. Each ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty. Library terms (CXL-1.0)
Related symbol libraries
Missing a symbol? Tell us which one.
Attributes for parts lists
Contacts and coils show their variable or address in a visible attribute (VAR), with COMMENT and ADDRESS as invisible fields. Function blocks have INSTANCE, and PT or PV for timers and counters. Modules have SLOT, MODULE_TYPE, ADDRESS_START, CHANNELS and SIGNAL; field wiring symbols have TAG and ADDRESS; the I/O address, rung number and cross-reference tags carry ADDRESS, RUNG, SHEET and COLUMN.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- The blocks are drawn at plotted size in millimetres (text 2.5 mm) on a 5 mm grid. Insert them at scale 1 in a layout, or at the scale of your drawing in model space.
- Ladder contacts, coils and wires are 20 mm long so that they chain without gaps; function blocks have pin stubs on a 5 mm pitch. Modules are inserted at their top left corner, field wiring symbols at the device end.
- Double-click a block (or run EATTEDIT) to enter the variable, address or tag. The field wiring symbols show typical connections: check them against the data sheet of your device.
About IEC 61131-3 and the generic symbols
The ladder contacts, coils and function blocks follow the graphical elements of IEC 61131-3 (Ladder Diagram). The symbols of PLC modules, racks and field wiring are not standardised: every manufacturer draws them differently.
The symbols are our own drawings, not copies of the standard, and the library is not certified against it. The module and wiring symbols are generic; match them to the devices and the drawing standard of your project.
Frequently asked questions
- Do these symbols follow IEC 61131-3?
- The ladder contacts, coils and standard function blocks are drawn after its graphical elements. The library is not certified, and the module and wiring symbols are generic because no standard defines them.
- Which PLC brands can I use them with?
- Any. The ladder elements are brand-neutral, the modules are generic boxes with channels, and you put the manufacturer, part number and address in the attributes.
- Can I use the symbols in commercial projects?
- Yes. They are free to use and modify in your own projects, including commercial ones. They are provided as is, without warranty. Please do not redistribute or resell the library; see the library terms.
- Can I change a symbol or add attributes?
- Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
- Where do I find a ready-made set of these symbols for AutoCAD?
- AutoCAD itself ships only a small set of sample blocks, so a full symbol set has to come from a library. Download the ZIP on this page and open the DWG: every symbol is a block. Insert one with INSERT (Blocks palette, Libraries tab, then pick the DWG) or drag it from DesignCenter (ADCENTER). You can also download a single symbol on its own.