KaynaklarDWG sembol kütüphaneleriISO 14084-2 power plant symbols
Instrumentation and control
ISO 14084-2 power plant symbols: Instrumentation and control: 63 ready-made AutoCAD blocks (DWG), free to download and use in your own projects, as a ZIP or one symbol at a time.
63 blocks for measurement and control: process control information symbols, sensors for temperature, level, weight, flow, speed, vibration and position, signals, emergency stops and the control processing elements such as set point, controller, integrator, selector and the arithmetic functions.
Version 1.0 · updated 17 Ekim 2026
Using AutoCAD 2017 or an earlier version? Download the 2010 format
Free to use and modify in your own projects, including commercial ones. The ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty.
Related symbol libraries
All 63 symbols
63 sembolün 63 tanesi
PCI, circle form, field mounted
PPD_X7201_PCI_CIRCLE_FIELDÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPCI, extended form, field mounted
PPD_X7202_PCI_EXT_FIELDÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPCI, circle form, local control system
PPD_X7203_PCI_CIRCLE_LOCALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPCI, extended form, local control system
PPD_X7204_PCI_EXT_LOCALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPCI, circle form, central control system
PPD_X7205_PCI_CIRCLE_CENTRALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPCI, extended form, central control system
PPD_X7206_PCI_EXT_CENTRALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPoint of measurement
PPD_1011_POINT_OF_MEASUREMENTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, built-in type, general
PPD_X7270_SENSOR_BUILT_INÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, general
PPD_751_SENSORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature measurement in line or duct
PPD_X7230_TEMP_IN_LINEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature gradient, outside
PPD_X7240_TEMP_GRADIENT_OUTSIDEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature gradient, middle
PPD_X7241_TEMP_GRADIENT_MIDDLEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature gradient, inside
PPD_X7242_TEMP_GRADIENT_INSIDEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature gradient on Y-piece
PPD_X7243_TEMP_GRADIENT_Y_PIECEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature measurement, outdoor
PPD_X7344_TEMP_OUTDOORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel, general
PPD_X7250_LEVELÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel, ultrasonic or radar type
PPD_X7251_LEVEL_ULTRASONICÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel, vibration type
PPD_X7253_LEVEL_VIBRATIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel, electrode type, general
PPD_X7254_LEVEL_ELECTRODEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCWeighing cell
PPD_X7261_WEIGHING_CELLÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCWeighing bridge for railway wagons
PPD_X7262_WEIGHING_BRIDGE_RAILÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCWeighing cell on tank
PPD_X7263_WEIGHING_CELL_TANKÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPropeller or turbine meter
PPD_X7271_FLOW_PROPELLERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCOrifice plate
PPD_X7272_ORIFICE_PLATEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow nozzle
PPD_X7273_FLOW_NOZZLEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCVenturi nozzle
PPD_X7274_VENTURI_NOZZLEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPitot tube
PPD_X7275_PITOT_TUBEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCVortex flow meter
PPD_X7276_VORTEXÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCUltrasonic flow meter, inline
PPD_X7277_ULTRASONIC_INLINEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCUltrasonic flow meter, clamp-on
PPD_X7278_ULTRASONIC_CLAMPÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCMagnetic flow meter
PPD_X7279_MAGNETIC_FLOWÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCCoriolis flow meter
PPD_X7280_CORIOLISÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCVariable area flow meter
PPD_X7281_VARIABLE_AREAÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow switch, paddle type
PPD_X7282_FLOW_SWITCH_PADDLEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, rotation
PPD_P127_SENSOR_ROTATIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, vibration, general
PPD_P128_SENSOR_VIBRATIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, vibration, rotating machines
PPD_P129_SENSOR_VIBRATION_ROTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLimit switch, mechanical type
PPD_X7290_LIMIT_SWITCH_MECHÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLimit switch, proximity type
PPD_X7291_LIMIT_SWITCH_PROXÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, axial displacement
PPD_P126_SENSOR_AXIALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, eccentricity, rotating machines
PPD_P130_SENSOR_ECCENTRICITYÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSignal, analogue
PPD_234_SIGNAL_ANALOGUEÖznitelikler
SERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSignal, digital
PPD_235_SIGNAL_DIGITALÖznitelikler
SERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCEmergency stop
PPD_X7283_EMERGENCY_STOPÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCEmergency wire stop along conveyor
PPD_X7284_EMERGENCY_WIRE_STOPÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSet point, form 1
PPD_P100_SET_POINT_1Öznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCSet point, form 2
PPD_X7363_SET_POINT_2Öznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCController, general
PPD_895_CONTROLLERÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCControl integrator
PPD_X7352_INTEGRATORÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCDead band
PPD_X7353_DEAD_BANDÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCFirst order delay
PPD_X7354_FIRST_ORDER_DELAYÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCLimit value, high or low
PPD_X7364_LIMIT_VALUEÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCMaximum selector
PPD_X7359_MAX_SELECTORÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCMinimum selector
PPD_X7360_MIN_SELECTORÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCSelector
PPD_X7362_SELECTORÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCSubtraction
PPD_X7358_SUBTRACTIONÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCSummation
PPD_X7365_SUMMATIONÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCDifference
PPD_X7355_DIFFERENCEÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCAverage
PPD_X7366_AVERAGEÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCMultiplication
PPD_X7356_MULTIPLICATIONÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCDivision
PPD_X7357_DIVISIONÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCDifferentiation
PPD_X7350_DIFFERENTIATIONÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESCPolygon table
PPD_X7351_POLYGON_TABLEÖznitelikler
TAGSERVICESETTINGINPUTOUTPUTLOCATIONREMARKSSTD_CLAUSESTD_REFDESC
Bir sembol mü eksik? Hangisi olduğunu bize yazın.
Attributes for parts lists
Every block has a visible tag next to the symbol (for example B-101 for a boiler, ST-101 for a steam turbine, M-101 for a motor, G-101 for a generator). The data of your equipment list are invisible attributes such as SERVICE, POWER_MW, SPEED_RPM, INLET_PRESSURE_BAR, FUEL and MANUFACTURER. STD_CLAUSE and STD_REF hold the entry number and the registration number of the symbol in ISO 14084-2 (for example X6904), so you can find it in the standard.
Export the blocks of a process diagram to Excel with BlockSync to build an equipment list, check it against the drawing and write the corrections back in one run, with preview and backup.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- The symbols are drawn in millimetres on the 2.5 mm module of the standard and are 5 to 30 mm in size. Insert them at scale 1 and scale the block to the size of your diagram. A few very large symbols, such as the chimney and gas turbines, are reduced so that they stay a usable size.
- The connections are short lines or arrows where the standard draws them. Where the standard shows a * on a boiler, the type of the combustion or heating system is meant: place the matching symbol from the section on boilers next to it.
- A symbol that appears in two sections of the standard, such as the shaft, has the same block name in both sections, so the two DWG files can be used in one drawing.