CADXChange

ResourcesElectrical schematic symbolsMotor control circuit diagram

Forward and reverse

A reversing starter for a 7.5 kW motor: two contactors that swap two phases, a shared stop button, separate forward and reverse buttons, and interlock contacts so that both contactors can never be on at once.

Free to use and modify in your own projects, including commercial ones. The ZIP holds the sample drawing, a template, a plot style table and a README; no add-in needed. The data in the drawing is made up, so it is not for design or construction. Provided as is, without warranty. Library terms (CXL-1.0)

Version 1.0 · updated October 21, 2026

This sample uses these resources

The symbols are blocks from our own libraries, with their attributes filled in. The sheet and its title block come from our ISO A3 title block template. Download them to draw your own diagrams.

Layers, styles and sheet setup are the same for every drawing in the series; they are described on the series page: Motor control circuit diagram

Title block fields

The attributes of the title block. Double-click it to fill them in, or write them for a whole set of drawings with BlockSync.

AttributeField on the sheetValue in this sample
COMPANYCOMPANYCADXChange
PROJECTPROJECTPump Station Motor Control
AREAAREAPump station
SYSTEMSYSTEM400 V / 230 V
CLIENTCLIENTSample
TITLEDRAWING TITLEMotor starter, forward and reverse
DRAWING_NODRAWING NO.E-102
CONTRACT_NOCONTRACT NO.—
REVREVA
DRAWNDRAWN—
CHECKEDCHECKED—
APPROVEDAPPROVED—
DATEDATE2026-10-21
SCALESCALENTS
SHEETSHEET1
SHEET_OFOF1

Revision table: R1 to R4, each with REV, DATE, DESCRIPTION and BY (16 attributes, empty in this sample).

Blocks in the drawing

The equipment list of the drawing: block name, symbol and how many times it is placed. BlockSync exports the same list from your own drawings.

SymbolBlockPlaced
JunctionIEC_JUNCTION15
Contactor, 3-poleIEC_CONTACTOR_3P2
TerminalIEC_TERMINAL2
Push-button, NOIEC_PUSHBUTTON_NO2
Auxiliary contact, NOIEC_AUX_CONTACT_NO2
Auxiliary contact, NCIEC_AUX_CONTACT_NC2
Relay / contactor coilIEC_COIL2
Circuit-breaker, 3-poleIEC_CIRCUIT_BREAKER_3P1
Thermal overload relay, 3PIEC_THERMAL_RELAY_3P1
Motor, three-phaseIEC_MOTOR_3PH1
Earth (ground)IEC_EARTH1
FuseIEC_FUSE1
Thermal overload contact, NCIEC_THERMAL_CONTACT_NC1
Push-button, NCIEC_PUSHBUTTON_NC1

Equipment schedule

One row per placed symbol, read from the attributes of the blocks in the drawing: what is shown on the sheet, and the schedule attributes that were filled in but are not shown. BlockSync exports these same attributes from your own drawings.

TagDescriptionShown on the sheetFilled in, not shown
Q1Circuit-breaker, 3-poleIEC_CIRCUIT_BREAKER_3PRATING_A = C20POLES = 3CURVE = CBREAKING_KA = 10VOLTAGE = 400 V
KM1Contactor, 3-poleIEC_CONTACTOR_3PRATING_A = 18 APOLES = 3UTILIZATION = AC-3COIL_VOLTAGE = 230 V AC
KM2Contactor, 3-poleIEC_CONTACTOR_3PRATING_A = 18 APOLES = 3UTILIZATION = AC-3COIL_VOLTAGE = 230 V AC
FR1Thermal overload relay, 3PIEC_THERMAL_RELAY_3PSETTING_A = 10-16 ACLASS = 10POLES = 3
M1Motor, three-phaseIEC_MOTOR_3PHPOWER_KW = 7.5 kWVOLTAGE = 400 VCURRENT = 14.8 ASPEED_RPM = 1455FREQUENCY = 50 Hz
PE1Earth (ground)IEC_EARTHEARTH_TYPE = PE
X2TerminalIEC_TERMINALTERMINAL_NO = 1
F2FuseIEC_FUSERATING_A = 4 AVOLTAGE = 230 VCLASS = gGBREAKING_KA = 50
X2TerminalIEC_TERMINALTERMINAL_NO = 2
FR1Thermal overload contact, NCIEC_THERMAL_CONTACT_NCCONTACT_NO = 95-96RATING_A = 6
SB1Push-button, NCIEC_PUSHBUTTON_NCLEGEND = STOPCONTACT_NO = 1 NCCOLOR = Red
SB2Push-button, NOIEC_PUSHBUTTON_NOLEGEND = FWDCONTACT_NO = 1 NOCOLOR = Green
KM1Auxiliary contact, NOIEC_AUX_CONTACT_NOCONTACT_NO = 13-14RATING_A = 10OPERATING_DEVICE = KM1
KM2Auxiliary contact, NCIEC_AUX_CONTACT_NCCONTACT_NO = 21-22RATING_A = 10OPERATING_DEVICE = KM2
KM1Relay / contactor coilIEC_COILVOLTAGE = 230 V ACPOWER_W = 8
SB3Push-button, NOIEC_PUSHBUTTON_NOLEGEND = REVCONTACT_NO = 1 NOCOLOR = Green
KM2Auxiliary contact, NOIEC_AUX_CONTACT_NOCONTACT_NO = 13-14RATING_A = 10OPERATING_DEVICE = KM2
KM1Auxiliary contact, NCIEC_AUX_CONTACT_NCCONTACT_NO = 21-22RATING_A = 10OPERATING_DEVICE = KM1
KM2Relay / contactor coilIEC_COILVOLTAGE = 230 V ACPOWER_W = 8

Manufacturer, model and remarks are left empty on every block, ready for your data. The values are examples.

More drawings in this series