KaynaklarDWG sembol kütüphaneleriISO 14617: Graphical symbols for diagrams
General symbols and connections
ISO 14617: Graphical symbols for diagrams: General symbols and connections: 197 ready-made AutoCAD blocks (DWG), free to download and use in your own projects, as a ZIP or one symbol at a time.
197 blocks: general function symbols, qualifiers, variability and direction marks, materials, pipe and line connections, joints, fittings and related devices.
Version 1.0 · updated 17 Ekim 2026
Using AutoCAD 2017 or an earlier version? Download the 2010 format
Free to use and modify in your own projects, including commercial ones. The ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty.
All 197 symbols
197 sembolün 197 tanesi
Complex device, functional unit
ISX_101_COMPLEX_DEVICE_FUNCTIONAL_UNITÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCTransition to higher level
ISX_130_TRANSITION_HIGHER_LEVELÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCTransition to higher or lower
ISX_132_TRANSITION_HIGHER_OR_LOWERÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCSelection of highest value
ISX_138_SELECTION_HIGHEST_VALUEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCRegistering; recording, printing
ISX_149_REGISTERING_RECORDING_PRINTINGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCChange of state, set value from below
ISX_171_CHANGE_STATE_SET_VALUE_FROM_BEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCChange of state, set value from above
ISX_172_CHANGE_STATE_SET_VALUE_FROM_ABÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCChange of state, upper or lower
ISX_173_CHANGE_STATE_UPPER_OR_LOWERÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCChange of state, equal to set value
ISX_174_CHANGE_STATE_EQUAL_SET_VALUEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCChange of state, about set value
ISX_175_CHANGE_STATE_ABOUT_SET_VALUEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCAuxiliary power input or output
ISX_183_AUXILIARY_POWER_INPUT_OR_OUTPUÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCSubtraction function component
ISX_X102_SUBTRACTION_FUNCTION_COMPONENTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCReverse function component
ISX_X104_REVERSE_FUNCTION_COMPONENTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCAveraging function component
ISX_X105_AVERAGING_FUNCTION_COMPONENTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCHydraulic controlling unit
ISX_X107_HYDRAULIC_CONTROLLING_UNITÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCDelay element with switch-on delay
ISX_X108_DELAY_ELEMENT_SWITCH_DELAYÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCAmplifier, frequency compensated
ISX_X110_AMPLIFIER_FREQUENCY_COMPENSATEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCOvercurrent relay, three outputs
ISX_X113_OVERCURRENT_RELAY_THREE_OUTPUTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCNon-linear inherent variability
ISX_205_NON_LINEAR_INHERENT_VARIABILITÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCResistor, pre-set adjustable
ISX_X201_RESISTOR_PRE_SET_ADJUSTABLEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCResistor, continuously adjustable
ISX_X203_RESISTOR_CONTINUOUSLY_ADJUSTABÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCResistor with manual adjustability
ISX_X204_RESISTOR_MANUAL_ADJUSTABILITYÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCResistor, motor adjustable
ISX_X205_RESISTOR_MOTOR_ADJUSTABLEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCResistor, non-linear variable
ISX_X206_RESISTOR_NON_LINEAR_VARIABLEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCAmplifier with adjustable gain
ISX_X207_AMPLIFIER_ADJUSTABLE_GAINÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCApproximately constant force/flow
ISX_223_APPROXIMATELY_CONSTANT_FORCE_FÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCSinusoidal force, motion or flow
ISX_224_SINUSOIDAL_FORCE_MOTION_OR_FLOÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCPulse-shaped force, motion or flow
ISX_225_PULSE_SHAPED_FORCE_MOTION_OR_FÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCSaw-tooth force, motion or flow
ISX_227_SAW_TOOTH_FORCE_MOTION_OR_FLOWÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCDirection of hydraulic power
ISX_243_DIRECTION_HYDRAULIC_POWERÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCDirection of pneumatic power
ISX_244_DIRECTION_PNEUMATIC_POWERÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFlow, alternative directions
ISX_250_FLOW_ALTERNATIVE_DIRECTIONSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCCircular motion, any direction
ISX_254_CIRCULAR_MOTION_ANY_DIRECTIONÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCCircular motion, alternating
ISX_256_CIRCULAR_MOTION_ALTERNATINGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCPartial reversal of motion
ISX_262_PARTIAL_REVERSAL_MOTIONÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCDirection of mass flow in pipeline
ISX_X242_DIRECTION_MASS_FLOW_PIPELINEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCDirection of mass flow in a valve
ISX_X243_DIRECTION_MASS_FLOW_VALVEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCHydraulic power source, simplified
ISX_X246_HYDRAULIC_POWER_SOURCE_SIMPLIFÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCGear pair, speed increasing
ISX_X249_GEAR_PAIR_SPEED_INCREASINGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCLinear motion, stop and restart
ISX_X254_LINEAR_MOTION_STOP_RESTARTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCLinear motion, timed restart
ISX_X255_LINEAR_MOTION_TIMED_RESTARTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCLinear motion, alternating, dwell
ISX_X256_LINEAR_MOTION_ALTERNATING_DWELÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCLinear motion, return with dwell
ISX_X257_LINEAR_MOTION_RETURN_DWELLÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCLinear motion, partial reversal
ISX_X258_LINEAR_MOTION_PARTIAL_REVERSALÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCCorrelation between two motions
ISX_X260_CORRELATION_BETWEEN_TWO_MOTIONÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCPump rotation and flow direction
ISX_X261_PUMP_ROTATION_FLOW_DIRECTIONÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCProtective gas discharge tube
ISX_X321_PROTECTIVE_GAS_DISCHARGE_TUBEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCInsulated pipeline or duct
ISX_X322_INSULATED_PIPELINE_OR_DUCTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCPipelines at heat exchanger
ISX_X349_PIPELINES_AT_HEAT_EXCHANGERÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCMechanical link, shaft, wire
ISX_403_MECHANICAL_LINK_SHAFT_WIREÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCInsulating mechanical link
ISX_404_INSULATING_MECHANICAL_LINKÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCNon-guided electromagnetic beam
ISX_411_NON_GUIDED_ELECTROMAGNETIC_BEAÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCPilot, drain or bleed line
ISX_422_PILOT_DRAIN_OR_BLEED_LINEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCUnidirectional information bus
ISX_442_UNIDIRECTIONAL_INFORMATION_BUSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCBidirectional information bus type
ISX_443_BIDIRECTIONAL_INFORMATION_BUSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFlexible insulating link, shaft
ISX_X404_FLEXIBLE_INSULATING_LINK_SHAFTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCElectropneumatic contactor
ISX_X405_ELECTROPNEUMATIC_CONTACTORÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCTwisted rectangular pipeline
ISX_X406_TWISTED_RECTANGULAR_PIPELINEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCInsulated pipeline or duct
ISX_X322_INSULATED_PIPELINE_OR_DUCT_P3Öznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCInsulated pipeline, separate heating
ISX_X408_INSULATED_PIPELINE_SEPARATE_HEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCJacketed insulated pipeline
ISX_X410_JACKETED_INSULATED_PIPELINEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFour pipelines, two flexible
ISX_X413_FOUR_PIPELINES_TWO_FLEXIBLEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFour pipelines forming a unit
ISX_X421_FOUR_PIPELINES_FORMING_UNITÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFour pipelines, two forming a unit
ISX_X422_FOUR_PIPELINES_TWO_FORMING_UNIÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCInternal pilot connection
ISX_X435_INTERNAL_PILOT_CONNECTIONÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCClosed end of pipeline or duct
ISX_503_CLOSED_END_PIPELINE_OR_DUCTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCJoint of multiple mechanical links
ISX_X503_JOINT_MULTIPLE_MECHANICAL_LINKÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCJoint of multiple connections
ISX_X506_JOINT_MULTIPLE_CONNECTIONSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFlange coupling, flange pair
ISX_511_FLANGE_COUPLING_FLANGE_PAIRÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCWelded, brazed, or soldered joint
ISX_515_WELDED_BRAZED_OR_SOLDERED_JOINÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCQuick coupling, self-mating
ISX_565_QUICK_COUPLING_SELF_MATINGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCQuick coupling, male, self-closing
ISX_566_QUICK_COUPLING_MALE_SELF_CLOSIÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCQuick coupling, female, self-closing
ISX_567_QUICK_COUPLING_FEMALE_SELF_CLOÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCQuick coupling, self-mating, closing
ISX_568_QUICK_COUPLING_SELF_MATING_CLOÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFixed portion of a connector pair
ISX_576_FIXED_PORTION_CONNECTOR_PAIRÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCMovable portion of connector pair
ISX_577_MOVABLE_PORTION_CONNECTOR_PAIRÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCConnection, n parallel branches
ISX_601_CONNECTION_N_PARALLEL_BRANCHESÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCThree parallel identical branches
ISX_X601_THREE_PARALLEL_IDENTICAL_BRANCÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCEight connections, four branching
ISX_X602_EIGHT_CONNECTIONS_FOUR_BRANCHIÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCThree connections, same sequence
ISX_X603_THREE_CONNECTIONS_SAME_SEQUENCÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCThree connections, reversed
ISX_X604_THREE_CONNECTIONS_REVERSEDÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCThree connections, changed
ISX_X605_THREE_CONNECTIONS_CHANGEDÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCConnections between components
ISX_X606_CONNECTIONS_BETWEEN_COMPONENTSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESC
Bir sembol mü eksik? Hangisi olduğunu bize yazın.
Attributes for parts lists
Symbols of devices carry a visible tag (for example V-101) and invisible attributes for the schedule: SERVICE, SIZE, FLOW_M3H, POWER_KW, RANGE, SIGNAL, MANUFACTURER, MODEL and REMARKS. Plain graphical symbols such as lines, arrows and qualifiers have no tag. All blocks carry STD_CLAUSE and STD_REF.
Export the blocks of a diagram to Excel with BlockSync, check the list against the drawing and write the corrections back in one run, with preview and backup.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- The symbols are drawn in millimetres on the module of the standard (2.5 mm), mostly 5 to 30 mm in size. Insert them at scale 1 and scale the block up or down to the size of your diagram.
- Place the block and join your lines to its ends. Where the standard shows a symbol together with a line or a stub, the line is part of the block. Explode a block if you need to adapt it.
- The standard orders its symbols as basic symbols, supplementary symbols that are combined with them, and application examples. The catalog follows that order, and the clause of every symbol is stored in the attribute STD_CLAUSE.