KaynaklarDWG sembol kütüphaneleriISO 14617: Graphical symbols for diagrams
Measurement and control
ISO 14617: Graphical symbols for diagrams: Measurement and control: 207 ready-made AutoCAD blocks (DWG), free to download and use in your own projects, as a ZIP or one symbol at a time.
207 blocks: sensors and measuring transducers, fittings for sensors, measuring instruments, counters and clocks, displays and signalling devices, analogue signal processing, functional links, points of measurement, operation of final controlling elements, information-processing functions, indication of location and complete control loop examples.
Version 1.0 · updated 17 Ekim 2026
Using AutoCAD 2017 or an earlier version? Download the 2010 format
Free to use and modify in your own projects, including commercial ones. The ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty.
All 207 symbols
207 sembolün 207 tanesi
Functional connection
ISX_401_FUNCTIONAL_CONNECTIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCJoint of connections
ISX_501_JOINT_CONNECTIONSÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow, alternative directions
ISX_250_FLOW_ALTERNATIVE_DIRECTIONSÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCMeasurement near vessel bottom
ISX_X1011_MEASUREMENT_NEAR_VESSEL_BOTTOMÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCMeasurement in a pipeline
ISX_X1012_MEASUREMENT_PIPELINEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCManual operation, final element
ISX_1021_MANUAL_OPERATION_FINAL_ELEMENTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic operation, final element
ISX_1022_AUTOMATIC_OPERATION_FINAL_ELEMÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDetent, discrete position
ISX_655_DETENT_DISCRETE_POSITIONÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCDetent, any position, drift left
ISX_660_DETENT_ANY_POSITION_DRIFT_LEFTÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCManual operation of valve
ISX_X1021_MANUAL_OPERATION_VALVEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCManual valve, return to closed
ISX_X1022_MANUAL_VALVE_RETURN_CLOSEDÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCManual valve, delayed return
ISX_X1023_MANUAL_VALVE_DELAYED_RETURNÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCManual valve, two stable positions
ISX_X1024_MANUAL_VALVE_TWO_STABLE_POSITIÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCManual valve, infinite positions
ISX_X1025_MANUAL_VALVE_INFINITE_POSITIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic valve, return to closed
ISX_X1026_AUTOMATIC_VALVE_RETURN_CLOSEDÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic valve, return to open
ISX_X1027_AUTOMATIC_VALVE_RETURN_OPENÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic valve, analogue signal
ISX_X1028_AUTOMATIC_VALVE_ANALOGUE_SIGNAÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic valve, return to closed 2
ISX_X1029_AUTOMATIC_VALVE_RETURN_CLOSEDÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic valve, return to open 2
ISX_X1030_AUTOMATIC_VALVE_RETURN_OPEN_2Öznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic operation of pump
ISX_X1031_AUTOMATIC_OPERATION_PUMPÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic valve, infinite positions
ISX_X1034_AUTOMATIC_VALVE_INFINITE_POSITÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic valve, analogue, form 2
ISX_X1035_AUTOMATIC_VALVE_ANALOGUE_FORMÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAutomatic valve, infinite, form 2
ISX_X1036_AUTOMATIC_VALVE_INFINITE_FORMÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCInformation-processing function
ISX_1041_INFORMATION_PROCESSING_FUNCTIOÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTime-shared processing function
ISX_1042_TIME_SHARED_PROCESSING_FUNCTIOÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSelection of highest value
ISX_138_SELECTION_HIGHEST_VALUEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCPrimary location, central room
ISX_1101_PRIMARY_LOCATION_CENTRAL_ROOMÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCAuxiliary location, central room
ISX_1102_AUXILIARY_LOCATION_CENTRAL_ROOÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCPrimary location, local panel
ISX_1103_PRIMARY_LOCATION_LOCAL_PANELÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCAuxiliary location, local panel
ISX_1104_AUXILIARY_LOCATION_LOCAL_PANELÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFunction with negated input
ISX_X1041_FUNCTION_NEGATED_INPUTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFunction with negated output
ISX_X1042_FUNCTION_NEGATED_OUTPUTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFunction with enabling
ISX_X1043_FUNCTION_ENABLINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFunction with negated enabling
ISX_X1044_FUNCTION_NEGATED_ENABLINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFunction with retained output
ISX_X1045_FUNCTION_RETAINED_OUTPUTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCManual switching, indication
ISX_X1046_MANUAL_SWITCHING_INDICATIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCManual setting with indication
ISX_X1047_MANUAL_SETTING_INDICATIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow rate indication
ISX_X1048_FLOW_RATE_INDICATIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPump motor power indication
ISX_X1049_PUMP_MOTOR_POWER_INDICATIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCVoltage registering
ISX_X1050_VOLTAGE_REGISTERINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPressure transmitting
ISX_X1051_PRESSURE_TRANSMITTINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPressure test connection
ISX_X1052_PRESSURE_TEST_CONNECTIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow ratio transmitter, recorder
ISX_X1053_FLOW_RATIO_TRANSMITTER_RECORDEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCStrainer differential pressure
ISX_X1054_STRAINER_DIFFERENTIAL_PRESSUREÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature scan with high alarm
ISX_X1055_TEMPERATURE_SCAN_HIGH_ALARMÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow recording with totaliser
ISX_X1056_FLOW_RECORDING_TOTALISERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCIndication of level in a vessel
ISX_X1057_INDICATION_LEVEL_VESSELÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel indication by viewing
ISX_X1058_LEVEL_INDICATION_BY_VIEWINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCVessel top temperature transmitter
ISX_X1059_VESSEL_TOP_TEMPERATURE_TRANSMIÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTelevision monitoring
ISX_X1060_TELEVISION_MONITORINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCReactive power indication, control
ISX_X1061_REACTIVE_POWER_INDICATION_CONTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCHigh-pressure alarm
ISX_X1062_HIGH_PRESSURE_ALARMÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature switching
ISX_X1063_TEMPERATURE_SWITCHINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature switching
ISX_X1064_TEMPERATURE_SWITCHINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel indication, recording, alarm
ISX_X1065_LEVEL_INDICATION_RECORDING_ALAÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSumming of flow rate signals
ISX_X1066_SUMMING_FLOW_RATE_SIGNALSÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSubtraction of flow rate signals
ISX_X1067_SUBTRACTION_FLOW_RATE_SIGNALSÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSquare root of flow signal
ISX_X1068_SQUARE_ROOT_FLOW_SIGNALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCHigh limit of flow signal
ISX_X1069_HIGH_LIMIT_FLOW_SIGNALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLowest flow signal selection
ISX_X1070_LOWEST_FLOW_SIGNAL_SELECTIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAnalogue to digital flow signal
ISX_X1071_ANALOGUE_DIGITAL_FLOW_SIGNALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow rate computing
ISX_X1072_FLOW_RATE_COMPUTINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow rate computing
ISX_X1073_FLOW_RATE_COMPUTINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel computing
ISX_X1074_LEVEL_COMPUTINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature indication, central room
ISX_X1075_TEMPERATURE_INDICATION_CENTRALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature indication, central 2
ISX_X1076_TEMPERATURE_INDICATION_CENTRALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature indication, local panel
ISX_X1077_TEMPERATURE_INDICATION_LOCAL_PÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCComputer control with back-up
ISX_X1081_COMPUTER_CONTROL_BACK_UPÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCRemote valve, return to closed
ISX_X1101_REMOTE_VALVE_RETURN_CLOSEDÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCRemote valve with position indication
ISX_X1102_REMOTE_VALVE_POSITION_INDICATIÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCRemote control valve, set value
ISX_X1103_REMOTE_CONTROL_VALVE_SET_VALUEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFlow rate feedback control
ISX_X1104_FLOW_RATE_FEEDBACK_CONTROLÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCTemperature-flow cascade control
ISX_X1105_TEMPERATURE_FLOW_CASCADE_CONTRÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow control, square-root based
ISX_X1106_FLOW_CONTROL_SQUARE_ROOT_BASEDÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCFlow control, high flow closing
ISX_X1107_FLOW_CONTROL_HIGH_FLOW_CLOSINGÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCSensor
ISX_751_SENSORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, form 2
ISX_752_SENSOR_FORM_2Öznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSignal converter, transducer
ISX_753_SIGNAL_CONVERTERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSignal converter, form 2
ISX_754_SIGNAL_CONVERTER_FORM_2Öznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCConverter, circuits separated
ISX_755_SIGNAL_CONVERTER_ISOLATEDÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCConverter, separated, form 2
ISX_756_SIGNAL_CONVERTER_ISOLATED_2Öznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCThermocouple
ISX_757_THERMOCOUPLEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTachometer generator
ISX_759_TACHOMETER_GENERATORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTransducer, synchro effect
ISX_760_SYNCHRO_TRANSDUCERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCCritical flow nozzle type
ISX_774_CRITICAL_FLOW_NOZZLE_TYPEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCConductive electrode type
ISX_IEC_CONDUCTIVE_ELECTRODE_TYPEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCTransmitting ultrasonic type
ISX_IEC_ULTRASONIC_TRANSMITTING_TYPEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCReceiving ultrasonic type
ISX_IEC_ULTRASONIC_RECEIVING_TYPEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCTransmit and receive ultrasonic
ISX_IEC_ULTRASONIC_BOTH_TYPEÖznitelikler
TAGREMARKSSTD_CLAUSESTD_REFDESCLevel sensor
ISX_X751_LEVEL_SENSORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel transducer, float type
ISX_X752_LEVEL_TRANSDUCER_FLOATÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel transducer, sonic, integral
ISX_X753_LEVEL_TRANSDUCER_SONICÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel transducer, sonic, separate
ISX_X754_LEVEL_TRANSDUCER_SONIC_SEPÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCLevel transducer, optical, separate
ISX_X755_LEVEL_TRANSDUCER_OPTICAL_SEPÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPressure sensor
ISX_X756_PRESSURE_SENSORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPressure sensor, strain gauge
ISX_X757_PRESSURE_SENSOR_STRAINÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPressure transducer, voltage out
ISX_X758_PRESSURE_TRANSDUCERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow rate sensor
ISX_X759_FLOW_RATE_SENSORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFlow transducer, nozzle, current out
ISX_X760_FLOW_TRANSDUCER_NOZZLEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature sensor, thermocouple
ISX_X761_TEMPERATURE_SENSOR_THERMOCOUPLEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature transducer, semiconductor
ISX_X762_TEMPERATURE_TRANSDUCER_SEMIÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, non-ionizing radiation
ISX_X763_RADIATION_SENSOR_NON_IONIZINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSensor, ionizing radiation
ISX_X764_RADIATION_SENSOR_IONIZINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCConverter, current to voltage
ISX_X765_CONVERTER_CURRENT_VOLTAGEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTachometer generator, DC type
ISX_X766_TACHOMETER_GENERATOR_DCÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTachometer generator, optical
ISX_X767_TACHOMETER_GENERATOR_OPTICALÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPosition transducer, differential
ISX_X768_POSITION_TRANSDUCER_LVDTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAngle transducer, pulse train out
ISX_X769_ANGLE_TRANSDUCER_PULSEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature transducer with contact
ISX_X770_TEMPERATURE_TRANSDUCER_CONTACTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature sensor in boss, pipeline
ISX_X801_TEMPERATURE_SENSOR_IN_BOSSÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCTemperature sensor, insertion pipe, tank
ISX_X802_TEMPERATURE_SENSOR_IN_PIPE_TANKÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCThermometer
ISX_831_THERMOMETERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCIndicating instrument
ISX_832_INDICATING_INSTRUMENTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCRecording instrument
ISX_833_RECORDING_INSTRUMENTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCIntegrating instrument
ISX_834_INTEGRATING_INSTRUMENTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCThermometer, degrees Celsius
ISX_X842_THERMOMETER_DEGREES_CÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCThermometer with contact
ISX_X843_THERMOMETER_WITH_CONTACTÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCSalinity meter
ISX_X846_SALINITY_METERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCRecording temperature meter
ISX_X851_RECORDING_TEMPERATURE_METERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCVolume meter, time integration
ISX_X855_VOLUME_METER_INTEGRATINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCCounter
ISX_841_COUNTERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCClock
ISX_842_CLOCKÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCMaster clock
ISX_843_MASTER_CLOCKÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCCounter with reset to 0
ISX_X871_COUNTER_RESET_ZEROÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDown counter with preset to n
ISX_X872_COUNTER_DOWN_PRESETÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCElectromechanical counter
ISX_X873_ELECTROMECHANICAL_COUNTERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCElectromechanical counter, postponed
ISX_X874_ELECTROMECH_COUNTER_POSTPONEDÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCCounter, manual reset to 0
ISX_X875_ELECTROMECH_COUNTER_MANUAL_RESETÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCCounter, electrical reset to 0
ISX_X876_ELECTROMECH_COUNTER_ELECTRIC_RESETÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCCam-driven counter, output at n
ISX_X877_CAM_COUNTER_OUTPUT_NÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDisplay unit
ISX_851_DISPLAY_UNITÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCMechanical indicator
ISX_863_MECHANICAL_INDICATORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCElectromechanical indicator
ISX_864_ELECTROMECH_INDICATORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCPosition indicator, 3 positions
ISX_865_POSITION_INDICATORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAcoustic signalling device
ISX_866_ACOUSTIC_SIGNALLING_DEVICEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCIndicator with automatic return
ISX_X893_INDICATOR_AUTO_RETURNÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCIndicator, manual reset
ISX_X894_INDICATOR_MANUAL_RESETÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCOvercurrent relay with indicator
ISX_X895_OVERCURRENT_RELAY_INDICATORÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAmplifier
ISX_891_AMPLIFIERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAmplifier, form 2
ISX_892_AMPLIFIER_FORM_2Öznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAmplifier with return channel
ISX_893_AMPLIFIER_RETURN_CHANNELÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCAmplifier with return, form 2
ISX_894_AMPLIFIER_RETURN_FORM_2Öznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFeedback controller
ISX_895_FEEDBACK_CONTROLLERÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCFeedback controller, form 2
ISX_896_FEEDBACK_CONTROLLER_FORM_2Öznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDevice for summing
ISX_X901_DEVICE_SUMMINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDevice for division
ISX_X902_DEVICE_DIVISIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDevice for averaging
ISX_X903_DEVICE_AVERAGINGÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDevice for bias
ISX_X904_DEVICE_BIASÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDevice for reverse function
ISX_X905_DEVICE_REVERSEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDevice for high limitation
ISX_X906_DEVICE_HIGH_LIMITATIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCDevice for low limitation
ISX_X907_DEVICE_LOW_LIMITATIONÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESCHigh limitation, negative input
ISX_X908_DEVICE_HIGH_LIMIT_NEGATIVEÖznitelikler
TAGSERVICERANGEUNITSIGNALLOCATIONMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFDESC
Bir sembol mü eksik? Hangisi olduğunu bize yazın.
Attributes for parts lists
Symbols of devices carry a visible tag (for example V-101) and invisible attributes for the schedule: SERVICE, SIZE, FLOW_M3H, POWER_KW, RANGE, SIGNAL, MANUFACTURER, MODEL and REMARKS. Plain graphical symbols such as lines, arrows and qualifiers have no tag. All blocks carry STD_CLAUSE and STD_REF.
Export the blocks of a diagram to Excel with BlockSync, check the list against the drawing and write the corrections back in one run, with preview and backup.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- The symbols are drawn in millimetres on the module of the standard (2.5 mm), mostly 5 to 30 mm in size. Insert them at scale 1 and scale the block up or down to the size of your diagram.
- Place the block and join your lines to its ends. Where the standard shows a symbol together with a line or a stub, the line is part of the block. Explode a block if you need to adapt it.
- The standard orders its symbols as basic symbols, supplementary symbols that are combined with them, and application examples. The catalog follows that order, and the clause of every symbol is stored in the attribute STD_CLAUSE.