Free data center layout blocks for AutoCAD (DWG): racks, cooling, power, rack elevations, server rooms
Data center layout symbols: 135 ready-made AutoCAD blocks (DWG), free to download and use in your own projects, as a ZIP or one symbol at a time.
135 blocks for data centres, server rooms and comms rooms: plan views at real size in millimetres and rack elevations at 1:1 with 1 U = 44.45 mm. Plan: racks and cabinets (600 and 800 mm wide, 1000 and 1200 mm deep, double-width, rear-door heat exchanger, open frames, wall and network cabinets), rack row layouts (rows of 10 and 5, overhead tray row, cold-aisle and hot-aisle pods, in-row cooling pod, four-row data hall), cooling (computer room air handlers, in-row coolers, coolant distribution unit, dry cooler, cassette and split units, humidifier), power (UPS, modular UPS, battery cabinets and racks, PDUs, remote power panel, switchgear, transformer, generators, ATS and STS), cable pathways and floor (trays, elbows, tees, busway, raised floor tiles, grid, cut-out, ramp, trench), fire, security and monitoring (smoke detectors, aspirating pipe, gas cylinder and nozzle, extinguisher, EPO button, leak cable, CCTV, card reader, doors, mantrap), support equipment, four room layouts (server room, comms room, data hall, UPS room) and six room modules. Elevations: rack frames from 6 U to 48 U, servers, GPU servers, blade chassis, storage, switches, routers, firewalls, patch and fibre panels, cable managers, console and KVM, rack PDUs, UPS, battery packs, blanking panels and shelves, six assembled rack elevations and rack tag, room label and aisle label markers.
Using AutoCAD 2017 or an earlier version? Download the 2010 format
Free to use and modify in your own projects, including commercial ones. The ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty.
After you download
Use the symbols across a whole drawing set
A symbol only helps when every drawing uses the same version of it.
- Open the DWG and copy the blocks you need into your drawing, or drag them in from DesignCenter. Insert them at scale 1; the README in this ZIP gives the drawing unit and the insertion point of each group.
- When a symbol changes later, replace the old block with the new one in every drawing in one run with BlockCopy, instead of opening each file.
- To count symbols or list their attributes across many drawings, export them to Excel with BlockSync and build a pivot table from the result.
Step-by-step guideBlockCopyBlockSync
Related guides:ATTSYNC Cleared My Attribute Values — How to Update Block Definitions SafelyCount Blocks Across Multiple Drawings — Build a BOM / Material Take-Off in Excel from a Whole Drawing Set
The tools are free for up to 10 files per batch; Pro removes the limit.
All 135 symbols
135 of 135 symbols

Server rack 600 x 1000
DCL_RACK_600X1000Attributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGPOWER_KWRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Server rack 600 x 1200
DCL_RACK_600X1200Attributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGPOWER_KWRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Server rack 750 x 1200
DCL_RACK_750X1200Attributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGPOWER_KWRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Server rack 800 x 1000
DCL_RACK_800X1000Attributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGPOWER_KWRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Server rack 800 x 1200
DCL_RACK_800X1200Attributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGPOWER_KWRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Double-width rack 1200 x 1200
DCL_RACK_1200X1200Attributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGPOWER_KWRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Rack with rear door heat exchanger 600 x 1350
DCL_RACK_RDHX_600X1350Attributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGPOWER_KWRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Open frame rack, 2 post
DCL_RACK_OPEN_2POSTAttributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Open frame rack, 4 post 600 x 1000
DCL_RACK_OPEN_4POSTAttributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Wall-mount cabinet 600 x 450
DCL_CAB_WALL_600X450Attributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Network cabinet 600 x 800
DCL_CAB_NETWORK_600X800Attributes
TAGDESIGNATIONSIZEU_HEIGHTMAX_LOAD_KGPOWER_KWRACK_IDMANUFACTURERMODELQTYREMARKSDESC
Rack row, 10 racks 600 x 1200
DCL_ROW_10Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Rack row, 5 racks 600 x 1000
DCL_ROW_5Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Rack row of 6 with overhead tray
DCL_ROW_OVERHEAD_TRAYAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Cold aisle pod, 2 x 10 racks
DCL_POD_COLD_2X10Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Cold aisle pod, 2 x 6 racks
DCL_POD_COLD_2X6Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Hot aisle pod, 2 x 10 racks
DCL_POD_HOT_2X10Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
In-row cooling pod, 2 x 12
DCL_POD_INROW_2X12Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Data hall, 4 rows of 10 racks
DCL_HALL_4ROWSAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Precision air conditioner 1000 x 890
DCL_CRAH_1000Attributes
TAGDESIGNATIONSIZECOOLING_KWPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Precision air conditioner 1800 x 890
DCL_CRAH_1800Attributes
TAGDESIGNATIONSIZECOOLING_KWPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Precision air conditioner 2600 x 890
DCL_CRAH_2600Attributes
TAGDESIGNATIONSIZECOOLING_KWPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
In-row cooler 300 x 1200
DCL_INROW_300Attributes
TAGDESIGNATIONSIZECOOLING_KWPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
In-row cooler 600 x 1200
DCL_INROW_600Attributes
TAGDESIGNATIONSIZECOOLING_KWPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Rear door heat exchanger 600 x 150
DCL_RDHXAttributes
TAGDESIGNATIONSIZECOOLING_KWMANUFACTURERMODELQTYREMARKSDESC
Coolant distribution unit 600 x 1200
DCL_CDU_600X1200Attributes
TAGDESIGNATIONSIZECOOLING_KWPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Dry cooler with 4 fans 4000 x 1200
DCL_DRYCOOLER_4FAttributes
TAGDESIGNATIONSIZECOOLING_KWPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Ceiling cassette air conditioner 840 x 840
DCL_CASSETTE_840Attributes
TAGDESIGNATIONSIZECOOLING_KWPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Wall-mounted indoor unit 1000 x 220
DCL_SPLIT_INDOORAttributes
TAGDESIGNATIONSIZECOOLING_KWPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Humidifier 600 x 600
DCL_HUMIDIFIERAttributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
UPS cabinet 800 x 900
DCL_UPS_800X900Attributes
TAGDESIGNATIONSIZEPOWER_KWVAMANUFACTURERMODELQTYREMARKSDESC
Modular UPS 600 x 1100
DCL_UPS_MODULAR_600X1100Attributes
TAGDESIGNATIONSIZEPOWER_KWVAMANUFACTURERMODELQTYREMARKSDESC
Battery cabinet 600 x 850
DCL_BATTERY_CABINETAttributes
TAGDESIGNATIONSIZEMAX_LOAD_KGAUTONOMY_MINMANUFACTURERMODELQTYREMARKSDESC
Battery rack 2000 x 700
DCL_BATTERY_RACKAttributes
TAGDESIGNATIONSIZEMAX_LOAD_KGAUTONOMY_MINMANUFACTURERMODELQTYREMARKSDESC
Power distribution unit 600 x 900
DCL_PDU_600X900Attributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Wide power distribution unit 1800 x 600
DCL_PDU_WIDE_1800Attributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Remote power panel 800 x 500
DCL_RPP_800X500Attributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Switchgear panel 800 x 1000
DCL_SWITCHGEAR_800Attributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Switchgear line-up, 3 panels 2400 x 1000
DCL_SWITCHGEAR_3PAttributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Transformer 1200 x 1000
DCL_TRANSFORMER_1200Attributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Generator set 500 kVA 3600 x 1400
DCL_GENERATOR_500Attributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Generator set 1500 kVA 5800 x 2300
DCL_GENERATOR_1500Attributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Automatic transfer switch 800 x 500
DCL_ATS_800X500Attributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Static transfer switch 600 x 900
DCL_STS_600X900Attributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Cable tray 300 x 3000
DCL_TRAY_300Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Cable tray 600 x 3000
DCL_TRAY_600Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Cable tray, 90 degree elbow 600
DCL_TRAY_ELBOW_600Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Cable tray, tee 600
DCL_TRAY_TEE_600Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Overhead busway 3000
DCL_BUSWAY_3000Attributes
TAGDESIGNATIONSIZEPOWER_KWAMPSMANUFACTURERMODELQTYREMARKSDESC
Busway tap-off box 300 x 250
DCL_BUSWAY_TAPAttributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Raised floor tile 600 x 600
DCL_TILE_SOLIDAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Perforated floor tile 600 x 600
DCL_TILE_PERFAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Floor grille tile 600 x 600
DCL_TILE_GRILLEAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Raised floor grid 6 x 6 tiles
DCL_TILE_GRID_6X6Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Floor cut-out with brush seal 300 x 150
DCL_CUTOUT_BRUSHAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Access ramp 3000 x 1500
DCL_RAMP_3000Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Cable trench 3000 x 300
DCL_TRENCH_3000Attributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Smoke detector
DCL_SMOKE_DETECTORAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Aspirating sampling pipe 3000
DCL_VESDA_PIPEAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Suppression gas cylinder 400 dia.
DCL_GAS_CYLINDERAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Suppression nozzle
DCL_GAS_NOZZLEAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Fire extinguisher
DCL_EXTINGUISHERAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Emergency power off button
DCL_EPO_BUTTONAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Leak detection cable 3000
DCL_LEAK_CABLEAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
CCTV camera with view
DCL_CCTVAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Card reader
DCL_CARD_READERAttributes
TAGDESIGNATIONSIZEACCESS_LEVELMANUFACTURERMODELQTYREMARKSDESC
Door 1000 with swing
DCL_DOOR_SINGLEAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Double door 1800 with swing
DCL_DOOR_DOUBLEAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Mantrap 2400 x 1800
DCL_MANTRAPAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Operations desk station 1800 x 800
DCL_NOC_STATIONAttributes
TAGDESIGNATIONSIZEPOWER_KWMANUFACTURERMODELQTYREMARKSDESC
Staging bench 2400 x 900
DCL_STAGING_BENCHAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Parts shelving 1000 x 450
DCL_SHELVINGAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Server lift 700 x 1200
DCL_SERVER_LIFTAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Crash cart 600 x 800
DCL_CRASH_CARTAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Tool and spares cabinet 900 x 500
DCL_TOOL_CABINETAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Server room 4200 x 6000, 8 racks
DCL_LAYOUT_SERVER_ROOMAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Comms room 3000 x 3600 with 2 racks
DCL_LAYOUT_COMMS_ROOMAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Data hall 9000 x 12000 with 2 pods
DCL_LAYOUT_DATA_HALLAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
UPS room 6000 x 4800
DCL_LAYOUT_UPS_ROOMAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Data hall shell 9000 x 12000
DCL_ROOM_DATA_HALLAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Server room shell 4200 x 6000
DCL_ROOM_SERVERAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Comms room shell 3000 x 3600
DCL_ROOM_COMMSAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
UPS room shell 6000 x 4800
DCL_ROOM_UPSAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Battery room shell 4200 x 3600
DCL_ROOM_BATTERYAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Meet-me room shell 3600 x 4800
DCL_ROOM_MMRAttributes
TAGDESIGNATIONSIZEMANUFACTURERMODELQTYREMARKSDESC
Rack frame 48U
DCL_FRAME_48UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWMAX_LOAD_KGMANUFACTURERMODELREMARKSDESC
Rack frame 45U
DCL_FRAME_45UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWMAX_LOAD_KGMANUFACTURERMODELREMARKSDESC
Rack frame 42U
DCL_FRAME_42UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWMAX_LOAD_KGMANUFACTURERMODELREMARKSDESC
Rack frame 24U
DCL_FRAME_24UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWMAX_LOAD_KGMANUFACTURERMODELREMARKSDESC
Rack frame 22U
DCL_FRAME_22UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWMAX_LOAD_KGMANUFACTURERMODELREMARKSDESC
Wall cabinet frame 12U
DCL_FRAME_12UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWMAX_LOAD_KGMANUFACTURERMODELREMARKSDESC
Wall cabinet frame 6U
DCL_FRAME_6UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWMAX_LOAD_KGMANUFACTURERMODELREMARKSDESC
Server 1U
DCL_EL_SERVER_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Server 2U
DCL_EL_SERVER_2UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Server 4U
DCL_EL_SERVER_4UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
GPU server 4U
DCL_EL_GPU_4UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Blade chassis 6U
DCL_EL_BLADE_6UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Blade chassis 10U
DCL_EL_BLADE_10UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Storage array 2U, 24 bays
DCL_EL_STORAGE_2UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Storage shelf 4U
DCL_EL_JBOD_4UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Switch 1U, 24 ports
DCL_EL_SWITCH_24Attributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPORTSPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Switch 1U, 48 ports
DCL_EL_SWITCH_48Attributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPORTSPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Modular switch 2U
DCL_EL_SWITCH_CHASSISAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Core switch chassis 8U
DCL_EL_SWITCH_COREAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Router 2U
DCL_EL_ROUTER_2UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Firewall 1U
DCL_EL_FIREWALL_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Patch panel 1U, 24 ports
DCL_EL_PATCH_24Attributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPORTSPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Patch panel 2U, 48 ports
DCL_EL_PATCH_48Attributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPORTSPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Fibre panel 1U, 12 duplex
DCL_EL_FIBRE_PANELAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPORTSPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Cable manager 1U
DCL_EL_MGR_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Cable manager 2U, D-rings
DCL_EL_MGR_2UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Brush panel 1U
DCL_EL_BRUSH_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Console server 1U
DCL_EL_CONSOLE_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPORTSPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
KVM console drawer 1U
DCL_EL_KVM_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Rack PDU 1U, 8 outlets
DCL_EL_PDU_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Rack UPS 2U
DCL_EL_UPS_2UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Rack UPS 3U
DCL_EL_UPS_3UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Battery pack 2U
DCL_EL_BATTERY_2UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Transfer switch 1U
DCL_EL_ATS_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Fan tray 1U
DCL_EL_FAN_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Blanking panel 1U
DCL_EL_BLANK_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Blanking panel 2U
DCL_EL_BLANK_2UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Blanking panel 4U
DCL_EL_BLANK_4UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Vented panel 1U
DCL_EL_VENT_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Shelf 1U
DCL_EL_SHELF_1UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Shelf 2U
DCL_EL_SHELF_2UAttributes
TAGDESIGNATIONSIZEU_HEIGHTU_POSITIONRACK_IDPOWER_WWEIGHT_KGMANUFACTURERMODELSERIAL_NOASSET_TAGREMARKSDESC
Server rack 42U, 24 x 1U servers
DCL_RACK_EL_SERVER_42UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWPOWER_KWMANUFACTURERMODELREMARKSDESC
Network rack 42U
DCL_RACK_EL_NETWORK_42UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWPOWER_KWMANUFACTURERMODELREMARKSDESC
Storage rack 42U
DCL_RACK_EL_STORAGE_42UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWPOWER_KWMANUFACTURERMODELREMARKSDESC
Blade rack 42U, 3 chassis
DCL_RACK_EL_BLADE_42UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWPOWER_KWMANUFACTURERMODELREMARKSDESC
Power rack 42U, UPS and battery packs
DCL_RACK_EL_POWER_42UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWPOWER_KWMANUFACTURERMODELREMARKSDESC
Wall cabinet 12U, network
DCL_RACK_EL_WALL_12UAttributes
TAGDESIGNATIONSIZEU_HEIGHTRACK_IDROWPOWER_KWMANUFACTURERMODELREMARKSDESC

Data room label
DCL_ROOM_LABELAttributes
TAGROOMCAPACITYTIERPOWER_KWAREA_M2REMARKSDESC
Missing a symbol? Tell us which one.
Attributes for parts lists
Plan blocks have a visible DESIGNATION next to them (for example Server rack 600 x 1200). Invisible attributes are SIZE, RACK_ID, POWER_KW, COOLING_KW, MAX_LOAD_KG, MANUFACTURER, MODEL, QTY and REMARKS where they apply. Rack elevation devices carry U_HEIGHT, U_POSITION, RACK_ID, POWER_W, WEIGHT_KG, SERIAL_NO, ASSET_TAG, MANUFACTURER and MODEL, all invisible so a full rack stays readable. The markers show RACK_ID, ROOM with CAPACITY, or AISLE.
Export the blocks to Excel with BlockSync to get an equipment schedule per rack with U positions, power and weight, add up the power per rack or per row, check it against the drawing and write corrections back in one run, with preview and backup.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- Plan blocks are drawn at real size, 1 drawing unit = 1 mm; insert them at scale 1 in a drawing in millimetres, or scale by 0.001 in metres. Rack elevations are front views at 1:1 too: 1 U is 44.45 mm and the faceplate is 482.6 mm wide. The catalog sheet shrinks every block to fit its cell, so a 1 U switch and a whole rack look alike in size there.
- In plan, the origin is the centre of the item, the front (cold side) of a rack faces -Y and the rear (hot side) +Y, so rotate rows to suit your room. Doors are drawn with a thin swing arc and dashed outlines mark containment or clearance. Each room layout has a room module of the same clear size and centre, so insert both at one point to get walls and door around the equipment.
- For elevations, frame and devices share one origin, the bottom centre of the rack space. Insert a frame at X, Y, then place each device at the same X with Y + (U position - 1) x 44.45, or start from one of the six assembled racks and swap devices. Set U_POSITION and RACK_ID on each device and the schedule builds itself. Use the plan blocks for the room and the elevations for each rack.
About the sizes
There is no single standard for how a data centre or server room is laid out. The 19-inch faceplate and the 1 U height are the usual rack convention, and the other sizes are typical working sizes, for example a 600 x 1200 mm rack or a 600 x 600 mm floor tile; they differ by manufacturer and country. Cooling capacity, power, floor loading, aisle widths, cable separation and fire protection come from the product data sheets and the rules that apply to your site, so take them from those and not from the block sizes.
The blocks are our own drawings, simplified to what matters on a plan or an elevation, and the library is not certified. It is meant to lay out a room and document racks, not to prove that a design meets electrical, fire, cooling or building rules. Check the data sheets of the equipment you choose and the regulations in your country, and have the final layout reviewed by a competent person.
Frequently asked questions
- Which items are in the library?
- Racks and cabinets, rack row layouts, cooling, power, cable pathways and floor, fire, security and monitoring, support equipment, room layouts, room modules, rack frames, servers and storage, network equipment, rack power and accessories, assembled rack elevations and 3 markers. The page above lists every group with its count.
- Can I build an equipment schedule from the rack elevations?
- Yes. Every device block has U_HEIGHT, U_POSITION, RACK_ID, POWER_W, WEIGHT_KG, SERIAL_NO and ASSET_TAG. Fill them in, export with BlockSync and you get a list by rack and U position, with the power and weight total per rack. The values in the blocks are empty on purpose, because they depend on the product you buy.
- Can I use the symbols in commercial projects?
- Yes. They are free to use and modify in your own projects, including commercial ones. They are provided as is, without warranty.
- Do the blocks follow a data centre design standard?
- No. They are typical sizes and the common 19-inch rack convention. Cooling, power, loading, aisle width and fire protection are set by your site rules and by the data sheet of the product, so check them before you fix a layout, then move or copy the blocks to fit.
- Can I change a symbol or add attributes?
- Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
- Where do I find a ready-made set of these symbols for AutoCAD?
- AutoCAD itself ships only a small set of sample blocks, so a full symbol set has to come from a library. Download the ZIP on this page and open the DWG: every symbol is a block. Insert one with INSERT (Blocks palette, Libraries tab, then pick the DWG) or drag it from DesignCenter (ADCENTER). You can also download a single symbol on its own.
Count the symbols and build a parts list
Because ratings and part numbers are attributes, the symbols of a whole project can be counted and listed without opening the drawings. Export the blocks to Excel, total them with a pivot table and write corrections back in one run, with preview and backup.
See how to count blocks with BlockSync