ResourcesDWG symbol librariesCommon electrical symbols (IEC 60617)
Installation plans
Common electrical symbols (IEC 60617): Installation plans: 67 ready-made AutoCAD blocks (DWG), free to download and use in your own projects, as a ZIP or one symbol at a time.
67 blocks: power stations and substations, overhead, underground and submarine lines, wiring and installation boxes, socket outlets, switches and push-buttons, luminaires and clocks.
Version 1.2 · updated October 25, 2026 · Check out what's changed
Using AutoCAD 2017 or an earlier version? Download the 2010 format
Free to use and modify in your own projects, including commercial ones. The ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty.
Sample drawings made with this library
Related symbol libraries
All 67 symbols
67 of 67 symbols
Substation, in service
IEC_STATION_SUBSTATIONAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCHydro station, planned
IEC_STATION_HYDRO_PLANNEDAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCHydro station, in service
IEC_STATION_HYDROAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCThermal station, planned
IEC_STATION_THERMAL_PLANNEDAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCThermal station, in service
IEC_STATION_THERMALAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCNuclear station, planned
IEC_STATION_NUCLEAR_PLANNEDAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCNuclear station, in service
IEC_STATION_NUCLEARAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCGeothermal station, planned
IEC_STATION_GEOTHERMAL_PLANNEDAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCGeothermal station, in service
IEC_STATION_GEOTHERMALAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSolar station, planned
IEC_STATION_SOLAR_PLANNEDAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSolar station, in service
IEC_STATION_SOLARAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCWind station, planned
IEC_STATION_WIND_PLANNEDAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCWind station, in service
IEC_STATION_WINDAttributes
TAGSTATION_NAMECAPACITY_MWVOLTAGE_KVOWNERREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCUnderground line
IEC_LINE_UNDERGROUNDAttributes
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSubmarine line
IEC_LINE_SUBMARINEAttributes
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCOverhead line
IEC_LINE_OVERHEADAttributes
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLine in a duct
IEC_LINE_DUCTAttributes
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLine in a six-way duct
IEC_LINE_SIX_WAY_DUCTAttributes
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCManhole for underground line
IEC_MANHOLEAttributes
ROUTECABLE_TYPELENGTH_MVOLTAGE_VREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCHead end with local antenna
IEC_HEAD_END_ANTENNAAttributes
DEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCDirectional coupler
IEC_DIRECTIONAL_COUPLERAttributes
DEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCBox, general symbol
IEC_BOXAttributes
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCConnection box
IEC_JUNCTION_BOXAttributes
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCConsumer's terminal
IEC_CONSUMER_TERMINALAttributes
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCDistribution centre
IEC_DISTRIBUTION_CENTREAttributes
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet
IEC_SOCKET_OUTLETAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMultiple socket outlet, 3
IEC_SOCKET_OUTLET_MULTIPLEAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMultiple socket outlet, form 2
IEC_SOCKET_OUTLET_MULTIPLE_2Attributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, protective contact
IEC_SOCKET_OUTLET_PEAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, sliding shutter
IEC_SOCKET_OUTLET_SHUTTERAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet with switch
IEC_SOCKET_OUTLET_SWITCHAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, interlocked switch
IEC_SOCKET_OUTLET_INTERLOCKAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, isolating transformer
IEC_SOCKET_OUTLET_ISOLATINGAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSocket outlet, telecom
IEC_SOCKET_TELECOMAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSwitch, general symbol
IEC_SWITCH_PLANAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCSwitch with pilot light
IEC_SWITCH_PILOT_LIGHTAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPeriod limiting switch
IEC_SWITCH_TIMEDAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESC2 pole switch
IEC_SWITCH_2POLEAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCMultiposition switch
IEC_SWITCH_MULTIPOSITIONAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESC2 way switch
IEC_SWITCH_2WAYAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCIntermediate switch
IEC_SWITCH_INTERMEDIATEAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCDimmer
IEC_DIMMERAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPull-cord switch
IEC_SWITCH_PULL_CORDAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPush-button
IEC_PUSH_BUTTON_PLANAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPush-button with indicator lamp
IEC_PUSH_BUTTON_LAMPAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCPush-button, protected
IEC_PUSH_BUTTON_PROTECTEDAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCTime switch
IEC_TIME_SWITCHAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCKey-operated switch
IEC_SWITCH_KEYAttributes
TAGCIRCUITRATING_AIP_RATINGMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLighting outlet position
IEC_LIGHT_OUTLETAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLighting outlet on wall
IEC_LIGHT_OUTLET_WALLAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLuminaire, fluorescent lamp
IEC_LUMINAIREAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLuminaire, several tubes
IEC_LUMINAIRE_MULTI_TUBEAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCLuminaire, five tubes
IEC_LUMINAIRE_5_TUBESAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSMANUFACTURERPART_NODESCProjector, general symbol
IEC_PROJECTORAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCSpot light
IEC_SPOT_LIGHTAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCFlood light
IEC_FLOOD_LIGHTAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCEmergency luminaire, special circuit
IEC_EMERGENCY_LUMINAIREAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCEmergency luminaire, self-contained
IEC_EMERGENCY_LUMINAIRE_SELFAttributes
TAGLAMPCIRCUITPOWER_WLUMENMOUNT_HEIGHT_MMMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCWater heater
IEC_WATER_HEATERAttributes
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESCTime clock, time recorder
IEC_TIME_CLOCKAttributes
TAGDEVICERATINGCIRCUITMANUFACTURERMODELREMARKSSTD_CLAUSESTD_REFMANUFACTURERPART_NODESC
Missing a symbol? Tell us which one.
Attributes for parts lists
Every block has a visible TAG attribute and the key parameter next to the symbol: the resistance of a resistor, the rated current of a breaker, the type of a transistor, the rated power of a motor. The other parameters (voltage, tolerance, breaking capacity, speed, frequency, contact numbers and so on) are attributes that do not show on the sheet.
Nearly all blocks also have MANUFACTURER and PART_NO, and every block has a DESC attribute holding the name of the symbol. Fill them in with the attribute editor, or export them from many drawings to Excel for a bill of materials and write the changes back with BlockSync. Many symbols also carry the entry number of IEC 60617 (STD_CLAUSE, for example 07-13-06) and the number in the standard's database (STD_REF, for example S00288) as invisible attributes, so a symbol can be found in the standard and listed in a schedule.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your drawing, or drag the blocks in from DesignCenter (ADCENTER).
- Insert a block and snap to the 5 mm grid. The insertion point is terminal 1, so the symbol lands exactly on the end of the wire.
- Fill in the tag, then double-click the block (or run EATTEDIT) to enter the rating, the type and the part number.
- To count symbols or list the attributes of many drawings, export the blocks to Excel with BlockSync and write corrected values back.
What changed in each version
Version 1.2 · October 25, 2026
Version 1.1 · October 21, 2026
The dimmer symbol now follows the IEC 60617 drawing: the switch stroke runs through the triangle.
Redrawn with more detail (1)
Dimmer