Topics:Power system condition monitoring symbolsSingle-line diagram symbolsBuilding services symbols
AutoCAD power system condition monitoring symbols (DWG): early warning for transformers, switchgear, cables and stations
Power system condition monitoring symbols: 113 ready-made AutoCAD blocks (DWG). A starter pack of 12 symbols is free; the Standard edition is $79.
Free starter pack: 12 symbols
The most-used symbols of this library, as AutoCAD blocks in one DWG. Free for everyone, for any project.
Residual current detector
Arc fibre sensor
Arc flash relay
Oil gas monitor, multi-gas
Partial discharge, UHF
Top oil temperature
Partial discharge, TEV
SF6 density monitor
Distributed temp sensing unit
Camera, thermal imaging
Inspection robot, rail-hung
Edge gateway
Standard: 113 symbols
All 113 symbols of the Standard edition in one download, ready to insert in AutoCAD. Pay once and keep the files.
Free starter pack
$0For everyone, for any project
- 12 symbols
- No sign-in
- One DWG
Library licence
$79
For one person
Education: free
- Pay once
Student or teacher?
Free for one year with your school e-mail address. Renew it with the same address.
Sign in with your school e-mail address, we check it, and the licence is added to your account.
Available soonEducation licences are for study and teaching, valid for one year, and renewed with your school e-mail address.
What each version contains
The symbols by group, and how many of each group every version holds.
| Content | Free | Standard |
|---|---|---|
| All symbols | 12 | 113 |
| Added by this version | — | +101 |
| Electrical fire monitoring | 1 | 14 |
| Arc flash protection | 2 | 12 |
| Transformer monitoring | 3 | 19 |
| Switchgear and GIS monitoring | 2 | 14 |
| Cable monitoring | 1 | 10 |
| Environment and safety monitoring | 1 | 12 |
| Inspection robots and thermography | 1 | 11 |
| Station system | 1 | 11 |
Show 1 more groupsShow fewer groups
| Lines and marks | — | 10 |
|---|
The free pack is a hand-picked selection. Standard is one purchase and gives you every symbol as DWG files.
113 symbols as ready-to-use AutoCAD blocks for the equipment that watches power facilities and warns before a fire or a failure: electrical fire monitoring (residual current, temperature and arc fault detectors, monitoring units, remote displays); arc flash protection (point and fibre sensors, relays, current check, trip outputs, compartment zones); transformer monitoring (dissolved gas, moisture, partial discharge, bushings, winding and oil temperature, tap changer, cooler, oil level, gas relay, vibration); switchgear and GIS monitoring (partial discharge, contact and busbar temperature, SF6 density, leakage and decomposition products, breaker mechanics); cable monitoring (distributed temperature fibre and zones, partial discharge, sheath and circulating currents, joints); environment and safety (temperature, humidity, water, oxygen, SF6 and hydrogen, door contacts, cameras); inspection robots and thermal imaging (tracked, wheeled and rail-hung robots, drones, charging bases, thermal gateways and cameras, inspection points); station systems (data concentrators, gateways, servers, switches, wireless nodes, time source, alarm column); and lines and marks for fibre, RS-485, Ethernet, wireless, alarm and trip.
Version 1.0 · updated November 25, 2026 · Check out what's changed
Sample drawings made with this library
All 113 symbols
113 of 113 symbols
Residual current detector
PMN_RC_DETECTORAttributes
TAGRANGE_MAALARM_MACHANNELSOUTPUTCIRCUITLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCResidual current, 4 channel
PMN_RC_DETECTOR_4CHAttributes
TAGRANGE_MAALARM_MACHANNELSOUTPUTCIRCUITLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTemperature monitor detector
PMN_TEMP_DETECTORAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTemperature sensor, contact
PMN_TEMP_SENSORAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCResidual current transformer
PMN_CT_RESIDUALAttributes
TAGRATIOACCURACYINNER_DIAMETER_MMCIRCUITTYPELOCATIONMANUFACTURERMODELREMARKSDESCResidual CT, split core
PMN_CT_SPLITAttributes
TAGRATIOACCURACYINNER_DIAMETER_MMCIRCUITTYPELOCATIONMANUFACTURERMODELREMARKSDESCResidual current and temp
PMN_RC_TEMP_COMBIAttributes
TAGRANGE_MAALARM_MACHANNELSOUTPUTCIRCUITLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCArc fault detector, circuit
PMN_ARC_FAULT_DETAttributes
TAGRANGE_MAALARM_MACHANNELSOUTPUTCIRCUITLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCElectrical fire monitor
PMN_EFM_UNITAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCElectrical fire monitor, wall
PMN_EFM_UNIT_WALLAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCRemote display
PMN_EFM_DISPLAYAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCMonitor power supply
PMN_EFM_PSUAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCAlarm relay output
PMN_ALARM_RELAYAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCBusbar joint temp point
PMN_BUSBAR_JOINTAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCArc point sensor
PMN_ARC_POINTAttributes
TAGSENSITIVITY_LUXTRIP_TIME_MSCOMPARTMENTOUTPUTCURRENT_CHECKLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCArc fibre sensor
PMN_ARC_FIBREAttributes
TAGSENSITIVITY_LUXTRIP_TIME_MSCOMPARTMENTOUTPUTCURRENT_CHECKLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCArc fibre loop
PMN_ARC_FIBRE_LOOPAttributes
TAGSENSITIVITY_LUXTRIP_TIME_MSCOMPARTMENTOUTPUTCURRENT_CHECKLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCArc flash relay
PMN_ARC_RELAYAttributes
TAGSENSITIVITY_LUXTRIP_TIME_MSCOMPARTMENTOUTPUTCURRENT_CHECKLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCArc relay, extension unit
PMN_ARC_RELAY_EXTAttributes
TAGSENSITIVITY_LUXTRIP_TIME_MSCOMPARTMENTOUTPUTCURRENT_CHECKLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCurrent check input
PMN_ARC_CT_INPUTAttributes
TAGSENSITIVITY_LUXTRIP_TIME_MSCOMPARTMENTOUTPUTCURRENT_CHECKLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTrip output
PMN_ARC_TRIP_OUTAttributes
TAGSENSITIVITY_LUXTRIP_TIME_MSCOMPARTMENTOUTPUTCURRENT_CHECKLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCLight-only mode mark
PMN_ARC_LIGHT_ONLYAttributes
TAGSENSITIVITY_LUXTRIP_TIME_MSCOMPARTMENTOUTPUTCURRENT_CHECKLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCBreaker compartment zone
PMN_ARC_ZONE_CBAttributes
TAGZONELENGTH_MALARM_CCHANNELLOCATIONMANUFACTURERMODELREMARKSDESCBusbar compartment zone
PMN_ARC_ZONE_BUSAttributes
TAGZONELENGTH_MALARM_CCHANNELLOCATIONMANUFACTURERMODELREMARKSDESCCable compartment zone
PMN_ARC_ZONE_CABLEAttributes
TAGZONELENGTH_MALARM_CCHANNELLOCATIONMANUFACTURERMODELREMARKSDESCArc eliminator
PMN_ARC_ELIMINATORAttributes
TAGSENSITIVITY_LUXTRIP_TIME_MSCOMPARTMENTOUTPUTCURRENT_CHECKLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCOil hydrogen monitor
PMN_TR_H2Attributes
TAGGASRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCOil gas monitor, multi-gas
PMN_TR_DGA_MULTIAttributes
TAGGASRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCOil gas monitor, 8 gases
PMN_TR_DGA_8Attributes
TAGGASRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCOil moisture sensor
PMN_TR_MOISTUREAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCPartial discharge, UHF
PMN_TR_PD_UHFAttributes
TAGMETHODFREQUENCY_BANDSENSITIVITY_PCCHANNELSOUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCPartial discharge, acoustic
PMN_TR_PD_AEAttributes
TAGMETHODFREQUENCY_BANDSENSITIVITY_PCCHANNELSOUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCPartial discharge, HFCT
PMN_TR_PD_HFCTAttributes
TAGMETHODFREQUENCY_BANDSENSITIVITY_PCCHANNELSOUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCBushing monitor
PMN_TR_BUSHINGAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCWinding temp, fibre optic
PMN_TR_WINDING_FOAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTop oil temperature
PMN_TR_TOP_OIL_TEMPAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCore ground current
PMN_TR_CORE_GNDAttributes
TAGRATIOACCURACYINNER_DIAMETER_MMCIRCUITTYPELOCATIONMANUFACTURERMODELREMARKSDESCCooler status monitor
PMN_TR_COOLINGAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTap changer monitor
PMN_TR_OLTCAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCOil level monitor
PMN_TR_OIL_LEVELAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCGas relay monitor
PMN_TR_BUCHHOLZAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCPressure relief monitor
PMN_TR_PRV_MONAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCVibration sensor
PMN_TR_VIBRATIONAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTransformer monitoring IED
PMN_TR_IEDAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTransformer, monitored
PMN_TR_MONITOREDAttributes
TAGTYPERATINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCPartial discharge, TEV
PMN_SG_PD_TEVAttributes
TAGMETHODFREQUENCY_BANDSENSITIVITY_PCCHANNELSOUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCGIS partial discharge, UHF
PMN_GIS_PD_UHFAttributes
TAGMETHODFREQUENCY_BANDSENSITIVITY_PCCHANNELSOUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCGIS partial discharge, acoustic
PMN_GIS_PD_AEAttributes
TAGMETHODFREQUENCY_BANDSENSITIVITY_PCCHANNELSOUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCContact temperature, wireless
PMN_SG_CONTACT_TEMPAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCable termination temp
PMN_SG_CABLE_HEAD_TEMPAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCBusbar temp, fibre optic
PMN_SG_BUSBAR_FOAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCSF6 density monitor
PMN_SG_SF6_DENSITYAttributes
TAGGASRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCSF6 leak sensor
PMN_SG_SF6_LEAKAttributes
TAGGASRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCSF6 decomposition sensor
PMN_SG_SF6_DECOMPAttributes
TAGGASRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCabinet humidity sensor
PMN_SG_HUMIDITYAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCBreaker mechanical monitor
PMN_SG_CB_MECHAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCBreaker travel sensor
PMN_SG_CB_TRAVELAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCPartial discharge host
PMN_SG_PD_HOSTAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTemperature receiver
PMN_SG_TEMP_RECEIVERAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCDistributed temp sensing unit
PMN_CB_DTS_UNITAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTemperature sensing fibre
PMN_CB_DTS_FIBREAttributes
TAGZONELENGTH_MALARM_CCHANNELLOCATIONMANUFACTURERMODELREMARKSDESCTemperature zone marker
PMN_CB_DTS_ZONEAttributes
TAGZONELENGTH_MALARM_CCHANNELLOCATIONMANUFACTURERMODELREMARKSDESCCable PD sensor, HFCT
PMN_CB_PD_HFCTAttributes
TAGMETHODFREQUENCY_BANDSENSITIVITY_PCCHANNELSOUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCSheath current monitor
PMN_CB_SHEATH_CURRENTAttributes
TAGRATIOACCURACYINNER_DIAMETER_MMCIRCUITTYPELOCATIONMANUFACTURERMODELREMARKSDESCEarth circulating current
PMN_CB_EARTH_CIRCAttributes
TAGRATIOACCURACYINNER_DIAMETER_MMCIRCUITTYPELOCATIONMANUFACTURERMODELREMARKSDESCCross-bonding box monitor
PMN_CB_CROSSBOND_BOXAttributes
TAGCHANNELSSUPPLY_VCOMMUNICATIONOUTPUTSMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCable joint temperature
PMN_CB_JOINT_TEMPAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTunnel point temperature
PMN_CB_TUNNEL_TEMPAttributes
TAGRANGE_CALARM_CSENSOR_TYPEOUTPUTMONITORED_ITEMLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCable vibration sensor
PMN_CB_VIBRATIONAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTemperature and humidity
PMN_ENV_TEMP_HUMAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCWater level sensor
PMN_ENV_WATER_LEVELAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCWater leak cable
PMN_ENV_WATER_LEAKAttributes
TAGMEDIUMLENGTH_MPROTOCOLFROM_TOLABELMANUFACTURERMODELREMARKSDESCOxygen deficiency sensor
PMN_ENV_O2_DEFICIENCYAttributes
TAGGASRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCSF6 room monitor
PMN_ENV_SF6_ROOMAttributes
TAGGASRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCHydrogen room sensor
PMN_ENV_H2_ROOMAttributes
TAGGASRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCDoor contact
PMN_ENV_DOORAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCamera, fixed
PMN_ENV_CAM_FIXEDAttributes
TAGRESOLUTIONLENSPROTECTIONSTREAMPOWERLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCamera, pan-tilt-zoom
PMN_ENV_CAM_PTZAttributes
TAGRESOLUTIONLENSPROTECTIONSTREAMPOWERLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCamera, thermal imaging
PMN_ENV_CAM_THERMALAttributes
TAGTEMP_RANGE_CACCURACY_CRESOLUTIONLENSOUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCamera, explosion-proof
PMN_ENV_CAM_EXAttributes
TAGRESOLUTIONLENSPROTECTIONSTREAMPOWERLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCNoise sensor
PMN_ENV_NOISEAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCInspection robot, tracked
PMN_INS_ROBOT_TRACKAttributes
TAGDRIVERUN_TIME_HPAYLOADPROTECTIONNAVIGATIONLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCInspection robot, wheeled
PMN_INS_ROBOT_WHEELAttributes
TAGDRIVERUN_TIME_HPAYLOADPROTECTIONNAVIGATIONLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCInspection robot, rail-hung
PMN_INS_ROBOT_RAILAttributes
TAGDRIVERUN_TIME_HPAYLOADPROTECTIONNAVIGATIONLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCInspection drone
PMN_INS_DRONEAttributes
TAGDRIVERUN_TIME_HPAYLOADPROTECTIONNAVIGATIONLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCCharging dock
PMN_INS_DOCKAttributes
TAGDRIVERUN_TIME_HPAYLOADPROTECTIONNAVIGATIONLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCInspection rail segment
PMN_INS_RAILAttributes
TAGMEDIUMLENGTH_MPROTOCOLFROM_TOLABELMANUFACTURERMODELREMARKSDESCRobot base station
PMN_INS_BASE_STATIONAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCInfrared imaging gateway
PMN_INS_IR_GATEWAYAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCThermal imager, fixed
PMN_INS_IR_FIXEDAttributes
TAGTEMP_RANGE_CACCURACY_CRESOLUTIONLENSOUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCInfrared inspection window
PMN_INS_IR_WINDOWAttributes
TAGMEASURANDRANGEALARM_1ALARM_2OUTPUTLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCInspection point marker
PMN_INS_POINTAttributes
TAGTYPERATINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCData concentrator
PMN_SYS_DATA_CONCAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCEdge gateway
PMN_SYS_EDGE_GWAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCServer
PMN_SYS_SERVERAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCMonitoring workstation
PMN_SYS_WORKSTATIONAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCNetwork switch
PMN_SYS_SWITCHAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCWireless node
PMN_SYS_WIRELESS_NODEAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCWireless repeater
PMN_SYS_WIRELESS_REPEATERAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCOptical interface
PMN_SYS_OPTICAL_IFAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCProtocol converter
PMN_SYS_PROTOCOL_CONVAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCTime synchronisation
PMN_SYS_TIME_SYNCAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCAlarm beacon column
PMN_SYS_BEACONAttributes
TAGFUNCTIONPORTSSUPPLY_VPROTOCOLMOUNTINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESCFibre optic link
PMN_LINE_FIBREAttributes
TAGMEDIUMLENGTH_MPROTOCOLFROM_TOLABELMANUFACTURERMODELREMARKSDESCEthernet link
PMN_LINE_ETHERNETAttributes
TAGMEDIUMLENGTH_MPROTOCOLFROM_TOLABELMANUFACTURERMODELREMARKSDESCWireless link
PMN_LINE_WIRELESSAttributes
TAGMEDIUMLENGTH_MPROTOCOLFROM_TOLABELMANUFACTURERMODELREMARKSDESCAlarm output line
PMN_LINE_ALARMAttributes
TAGMEDIUMLENGTH_MPROTOCOLFROM_TOLABELMANUFACTURERMODELREMARKSDESCTrip signal line
PMN_LINE_TRIPAttributes
TAGMEDIUMLENGTH_MPROTOCOLFROM_TOLABELMANUFACTURERMODELREMARKSDESC4-20 mA loop
PMN_LINE_4_20MAAttributes
TAGMEDIUMLENGTH_MPROTOCOLFROM_TOLABELMANUFACTURERMODELREMARKSDESCLevel mark, warning
PMN_LEVEL_WARNINGAttributes
TAGTYPERATINGLOCATIONADDRESSMANUFACTURERMODELREMARKSDESC
Copyright CADXChange. Use and modify the symbols freely in your own drawings and projects, including commercial ones; credit and a link are needed only when you publish them. Please do not redistribute or resell the library. Each ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty. Library terms (CXL-1.0)
Related symbol libraries
Missing a symbol? Tell us which one.
Attributes for parts lists
Every block has a visible tag next to the symbol (for example DGA-1 for a gas monitor, PD-1 for a partial discharge sensor, CAM-1 for a camera). The data of your schedules are invisible attributes: LOCATION and ADDRESS for most devices; RANGE, ALARM_1 and ALARM_2 for sensors; CHANNELS and PROTOCOL for units and gateways; LENGTH_M for fibre and cable items; LENS and RESOLUTION for cameras; plus MANUFACTURER, MODEL and REMARKS. Export them to Excel with BlockSync and the point list is ready.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your drawing, or drag the blocks in from DesignCenter (ADCENTER).
- The symbols are drawn at the plotted size in millimetres and have the size and style of the power system single-line library, so they can share a drawing with it. Insert them at scale 1 and scale the block if your drawing needs a different size.
- Field sensors are circles with a short code and a lead at the bottom; units, hosts and gateways are boxes with a status dot and connections left and right. Sensors that clamp a conductor are rings on a horizontal line. Zones and compartments are dashed outlines: scale the inserted block to your drawing.
- Letters at the lower right of a circle name the method (U for ultra high frequency, A for acoustic, T for transient earth voltage). Change the letters in the block if your legend differs.
About the symbols
There is no graphic standard for monitoring equipment, so the symbols follow the usual practice of the trade: sensors as circles with a code, analysers as double circles, units as boxes with a status dot. Smoke, heat, flame, linear heat and aspirating fire detection are in the power system fire protection library, and the single-line symbols of the equipment itself are in the power system libraries.
The blocks are our own drawings, not copies of a standard, and the library is not certified. Check them against the legend of your project and your client, and change a block if yours differs.
What changed in each version
Version 1.0 · November 25, 2026
New symbols (113)
Residual current detector · Residual current, 4 channel · Temperature monitor detector · Temperature sensor, contact · Residual current transformer · Residual CT, split core · Residual current and temp · Arc fault detector, circuit · Electrical fire monitor · Electrical fire monitor, wall · Remote display · Monitor power supply · Alarm relay output · Busbar joint temp point · Arc point sensor · Arc fibre sensor · Arc fibre loop · Arc flash relay · Arc relay, extension unit · Current check input · Trip output · Light-only mode mark · Breaker compartment zone · Busbar compartment zone · Cable compartment zone · Arc eliminator · Oil hydrogen monitor · Oil gas monitor, multi-gas · Oil gas monitor, 8 gases · Oil moisture sensor · Partial discharge, UHF · Partial discharge, acoustic · Partial discharge, HFCT · Bushing monitor · Winding temp, fibre optic · Top oil temperature · Core ground current · Cooler status monitor · Tap changer monitor · Oil level monitor · 73 more
Frequently asked questions
- Does the library follow a standard?
- No standard defines graphic symbols for condition monitoring, so the symbols are drawn after the usual practice of the trade and in the same style as the power system single-line library. Standards for electrical fire monitoring, arc flash testing and gas analysis describe the function, not the figure. The library does not replace the rules of your project.
- Does it include fire detectors?
- Smoke, heat, flame, linear heat and aspirating detectors are in the power system fire protection library, so the two libraries do not overlap. Use this one for what warns before a fire: electrical fire monitoring, arc flash protection and equipment condition monitoring.
- Can I use the symbols in commercial projects?
- Yes, once you hold the licence. You may use and modify them in your own projects, including commercial ones. They are provided as is, without warranty. Please do not redistribute or resell the library; see the library terms.
- What do I get free, and what is in the paid library?
- A starter pack of 12 symbols and every single symbol preview are free to look at. The paid library has all the symbols in one DWG, one block per symbol, with a ZIP for AutoCAD 2018 and later and one for AutoCAD 2010.
- Can I change a symbol or add attributes?
- Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
- Where do I find a ready-made set of these symbols for AutoCAD?
- AutoCAD itself ships only a small set of sample blocks, so a full symbol set has to come from a library. Download the ZIP on this page and open the DWG: every symbol is a block. Insert one with INSERT (Blocks palette, Libraries tab, then pick the DWG) or drag it from DesignCenter (ADCENTER). You can also download a single symbol on its own.