Topics:Electrical schematic symbols
Free AutoCAD telecom transmission symbols (DWG), IEC 60617-10 style
Antennas, waveguides, modulation, filters and optical fibre (IEC 60617): 206 ready-made AutoCAD blocks (DWG). A starter pack of 30 symbols is free; the Standard edition is $29.
Free starter pack: 30 symbols
The most-used symbols of this library, as AutoCAD blocks in one DWG. Free for everyone, for any project.
Plane polarization
Antenna
Radio station
Waveguide, rectangular
Discontinuity, two-port
Mode filter
Three-port junction
Coupler to cavity resonator
Maser
Pulse-position modulation
Signal generator
Amplifier
Filter
Amplitude limiter
Modulator, demodulator
Carrier frequency
Optical fibre
Circular polarization
Antenna, circular polar.
Radio station, trans. + rec.
Waveguide, rectangular, TE01
Matching device, adjustable
Microwave isolator
Three-port, E-plane T
Coupler to rect. waveguide
Maser used as amplifier
Pulse-frequency modulation
Sine-wave generator, 500 Hz
Amplifier, boxed
High-pass filter
Standard: 206 symbols
All 206 symbols of the Standard edition in one download, ready to insert in AutoCAD. Pay once and keep the files.
Free starter pack
$0For everyone, for any project
- 30 symbols
- No sign-in
- One DWG
Library licence
$29
For one person
Education: free
- Pay once
Student or teacher?
Free for one year with your school e-mail address. Renew it with the same address.
Sign in with your school e-mail address, we check it, and the licence is added to your account.
Available soonEducation licences are for study and teaching, valid for one year, and renewed with your school e-mail address.
What each version contains
The symbols by group, and how many of each group every version holds.
| Content | Free | Standard |
|---|---|---|
| All symbols | 30 | 206 |
| Added by this version | — | +176 |
| Polarization and direction indications | 2 | 8 |
| Antennas | 2 | 20 |
| Radio stations | 2 | 7 |
| Waveguides and reflectors | 2 | 14 |
| Discontinuities and terminations | 2 | 18 |
| Microwave devices and SAW devices | 2 | 9 |
| Junctions and circulators | 2 | 18 |
| Couplers | 2 | 7 |
Show 9 more groupsShow fewer groups
| Masers and lasers | 2 | 6 |
|---|---|---|
| Pulse modulation | 2 | 7 |
| Generators and converters | 2 | 12 |
| Amplifiers and attenuators | 2 | 4 |
| Filters and correctors | 2 | 20 |
| Limiters and clippers | 1 | 6 |
| Modulators and multiplexers | 1 | 10 |
| Frequency spectrum marks | 1 | 24 |
| Optical fibre and guided light | 1 | 16 |
The free pack is a hand-picked selection. Standard is one purchase and gives you every symbol as DWG files.
206 symbols as ready-to-use AutoCAD blocks, drawn after IEC 60617-10: polarization and direction indications, antennas, radio stations, waveguides and reflectors, discontinuities and terminations, microwave and surface-acoustic-wave devices, junctions and circulators, couplers, masers and lasers, pulse modulation, generators and converters, amplifiers and attenuators, filters and correctors, limiters and clippers, modulators and multiplexers, frequency spectrum marks, and optical fibre and guided light devices.
Version 1.1 · updated October 21, 2026 · Check out what's changed
All 206 symbols
206 of 206 symbols
Direction fixed in azimuth
TLX_S01096_DIRECTION_FIXED_IN_AZIMUTHAttributes
REMARKSSTD_CLAUSESTD_REFDESCDirection fixed in elevation
TLX_S01098_DIRECTION_FIXED_IN_ELEVATIONAttributes
REMARKSSTD_CLAUSESTD_REFDESCAntenna, circular polar.
TLX_S01103_ANTENNA_CIRCULAR_POLARAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAntenna, variable azimuth
TLX_S01104_ANTENNA_VARIABLE_AZIMUTHAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAntenna, fixed, horizontal
TLX_S01105_ANTENNA_FIXED_HORIZONTALAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAntenna, variable elevation
TLX_S01106_ANTENNA_VARIABLE_ELEVATIONAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCDirection finding antenna
TLX_S01107_DIRECTION_FINDING_ANTENNAAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCDirectional antenna
TLX_S01108_DIRECTIONAL_ANTENNAAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCRadar antenna
TLX_S01109_RADAR_ANTENNAAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAntenna, turnstile
TLX_S01110_ANTENNA_TURNSTILEAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAntenna, loop or frame
TLX_S01111_ANTENNA_LOOP_OR_FRAMEAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAntenna, rhombic
TLX_S01112_ANTENNA_RHOMBICAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAntenna, magnetic rod
TLX_S01114_ANTENNA_MAGNETIC_RODAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCDipole, folded
TLX_S01116_DIPOLE_FOLDEDAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCFolded dipole, balun, feeder
TLX_S01119_FOLDED_DIPOLE_BALUN_FEEDERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCSlot antenna with feeder
TLX_S01120_SLOT_ANTENNA_WITH_FEEDERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAntenna, horn type
TLX_S01121_ANTENNA_HORN_TYPEAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCheese reflector, horn
TLX_S01122_CHEESE_REFLECTOR_HORNAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAntenna, parabolic, feeder
TLX_S01123_ANTENNA_PARABOLIC_FEEDERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCHorn antenna with reflector
TLX_S01124_HORN_ANTENNA_WITH_REFLECTORAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCRadio station
TLX_S01125_RADIO_STATIONAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCRadio station, trans. + rec.
TLX_S01126_RADIO_STATION_TRANS_RECAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCRadio station, DF receiving
TLX_S01127_RADIO_STATION_DF_RECEIVINGAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCRadio station, beacon
TLX_S01128_RADIO_STATION_BEACONAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCSpace station
TLX_S01133_SPACE_STATIONAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCEarth station, tracking only
TLX_S01136_EARTH_STATION_TRACKING_ONLYAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCEarth station, communicating
TLX_S01137_EARTH_STATION_COMMUNICATINGAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCWaveguide, rectangular, TE01
TLX_S01139_WAVEGUIDE_RECTANGULAR_TE01Attributes
REMARKSSTD_CLAUSESTD_REFDESCStripline, two ground planes
TLX_S01144_STRIPLINE_TWO_GROUND_PLANESAttributes
REMARKSSTD_CLAUSESTD_REFDESCMatching device, adjustable
TLX_S01157_MATCHING_DEVICE_ADJUSTABLEAttributes
REMARKSSTD_CLAUSESTD_REFDESCMatching device, slide screw
TLX_S01158_MATCHING_DEVICE_SLIDE_SCREWAttributes
REMARKSSTD_CLAUSESTD_REFDESCMatching device, multi-stub
TLX_S01160_MATCHING_DEVICE_MULTI_STUBAttributes
REMARKSSTD_CLAUSESTD_REFDESCDiscont., parallel resonant
TLX_S01165_DISCONT_PARALLEL_RESONANTAttributes
REMARKSSTD_CLAUSESTD_REFDESCTermination, short-circuit
TLX_S01178_TERMINATION_SHORT_CIRCUITAttributes
REMARKSSTD_CLAUSESTD_REFDESCTermination, sliding short
TLX_S01179_TERMINATION_SLIDING_SHORTAttributes
REMARKSSTD_CLAUSESTD_REFDESCBand-pass filter, gas disch.
TLX_S01173_BAND_PASS_FILTER_GAS_DISCHAttributes
REMARKSSTD_CLAUSESTD_REFDESCSAW device, two-port, total
TLX_S01182_SAW_DEVICE_TWO_PORT_TOTALAttributes
REMARKSSTD_CLAUSESTD_REFDESCSAW device, part reflecting
TLX_S01183_SAW_DEVICE_PART_REFLECTINGAttributes
REMARKSSTD_CLAUSESTD_REFDESCThree-port junction, divider
TLX_S01188_THREE_PORT_JUNCTION_DIVIDERAttributes
REMARKSSTD_CLAUSESTD_REFDESCFour-port junction, crossed
TLX_S01190_FOUR_PORT_JUNCTION_CROSSEDAttributes
REMARKSSTD_CLAUSESTD_REFDESCQuadrature hybrid junction
TLX_S01194_QUADRATURE_HYBRID_JUNCTIONAttributes
REMARKSSTD_CLAUSESTD_REFDESCCirculator, three-port
TLX_S01196_CIRCULATOR_THREE_PORTAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCirculator, four-port
TLX_S01197_CIRCULATOR_FOUR_PORTAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCirculator, reversible
TLX_S01198_CIRCULATOR_REVERSIBLEAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCField-polarization rotator
TLX_S01199_FIELD_POLARIZATION_ROTATORAttributes
REMARKSSTD_CLAUSESTD_REFDESCMicrowave switch, 2-position
TLX_S01200_MICROWAVE_SWITCH_2_POSITIONAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCMicrowave switch, 3-position
TLX_S01201_MICROWAVE_SWITCH_3_POSITIONAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCMicrowave switch, 4-position
TLX_S01202_MICROWAVE_SWITCH_4_POSITIONAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCoupler to cavity resonator
TLX_S01204_COUPLER_TO_CAVITY_RESONATORAttributes
REMARKSSTD_CLAUSESTD_REFDESCCoupler to rect. waveguide
TLX_S01205_COUPLER_TO_RECT_WAVEGUIDEAttributes
REMARKSSTD_CLAUSESTD_REFDESCWindow coupler at a junction
TLX_S01207_WINDOW_COUPLER_AT_A_JUNCTIONAttributes
REMARKSSTD_CLAUSESTD_REFDESCMaser used as amplifier
TLX_S01213_MASER_USED_AS_AMPLIFIERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCLaser used as generator
TLX_S01215_LASER_USED_AS_GENERATORAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCRuby laser generator
TLX_S01216_RUBY_LASER_GENERATORAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCRuby laser, xenon lamp pump
TLX_S01217_RUBY_LASER_XENON_LAMP_PUMPAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCPulse-frequency modulation
TLX_S01219_PULSE_FREQUENCY_MODULATIONAttributes
REMARKSSTD_CLAUSESTD_REFDESCPulse-amplitude modulation
TLX_S01220_PULSE_AMPLITUDE_MODULATIONAttributes
REMARKSSTD_CLAUSESTD_REFDESCPulse-code mod., 3-out-of-7
TLX_S01224_PULSE_CODE_MOD_3_OUT_OF_7Attributes
REMARKSSTD_CLAUSESTD_REFDESCSignal generator
TLX_S01225_SIGNAL_GENERATORAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCSine-wave generator, 500 Hz
TLX_S01226_SINE_WAVE_GENERATOR_500_HZAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCSaw-tooth generator, 500 Hz
TLX_S01227_SAW_TOOTH_GENERATOR_500_HZAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCPulse generator
TLX_S01228_PULSE_GENERATORAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCSine generator, adjustable
TLX_S01229_SINE_GENERATOR_ADJUSTABLEAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCCode converter, binary code
TLX_S01236_CODE_CONVERTER_BINARY_CODEAttributes
REMARKSSTD_CLAUSESTD_REFDESCAmplifier, boxed
TLX_S01240_AMPLIFIER_BOXEDAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAttenuator, fixed loss
TLX_S01244_ATTENUATOR_FIXED_LOSSAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCAttenuator, variable loss
TLX_S01245_ATTENUATOR_VARIABLE_LOSSAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCHigh-pass filter
TLX_S01247_HIGH_PASS_FILTERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCLow-pass filter
TLX_S01248_LOW_PASS_FILTERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCBand-pass filter
TLX_S01249_BAND_PASS_FILTERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCBand-stop filter
TLX_S01250_BAND_STOP_FILTERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCPhase distortion corrector
TLX_S01259_PHASE_DISTORTION_CORRECTORAttributes
REMARKSSTD_CLAUSESTD_REFDESCDelay distortion corrector
TLX_S01260_DELAY_DISTORTION_CORRECTORAttributes
REMARKSSTD_CLAUSESTD_REFDESCElectronic chopping device
TLX_S01263_ELECTRONIC_CHOPPING_DEVICEAttributes
REMARKSSTD_CLAUSESTD_REFDESCModulator, double sideband
TLX_S01279_MODULATOR_DOUBLE_SIDEBANDAttributes
REMARKSSTD_CLAUSESTD_REFDESCConcentrator, with m and n
TLX_S01285_CONCENTRATOR_WITH_M_AND_NAttributes
REMARKSSTD_CLAUSESTD_REFDESCMultiplexing, demultiplexing
TLX_S01288_MULTIPLEXING_DEMULTIPLEXINGAttributes
REMARKSSTD_CLAUSESTD_REFDESCSuppressed-carrier frequency
TLX_S01292_SUPPRESSED_CARRIER_FREQUENCYAttributes
REMARKSSTD_CLAUSESTD_REFDESCSupergroup pilot frequency
TLX_S01295_SUPERGROUP_PILOT_FREQUENCYAttributes
REMARKSSTD_CLAUSESTD_REFDESCSuppressed pilot frequency
TLX_S01296_SUPPRESSED_PILOT_FREQUENCYAttributes
REMARKSSTD_CLAUSESTD_REFDESCAdded measuring, on request
TLX_S01298_ADDED_MEASURING_ON_REQUESTAttributes
REMARKSSTD_CLAUSESTD_REFDESCFrequency band, mastergroup
TLX_S01301_FREQUENCY_BAND_MASTERGROUPAttributes
REMARKSSTD_CLAUSESTD_REFDESCErect band, several channels
TLX_S01304_ERECT_BAND_SEVERAL_CHANNELSAttributes
REMARKSSTD_CLAUSESTD_REFDESCAmplitude-modulated carrier
TLX_S01308_AMPLITUDE_MODULATED_CARRIERAttributes
REMARKSSTD_CLAUSESTD_REFDESCReduced-carrier, erect SSB
TLX_S01313_REDUCED_CARRIER_ERECT_SSBAttributes
REMARKSSTD_CLAUSESTD_REFDESCAM carrier, vestigial band
TLX_S01315_AM_CARRIER_VESTIGIAL_BANDAttributes
REMARKSSTD_CLAUSESTD_REFDESCFibre, single mode stepped
TLX_S01320_FIBRE_SINGLE_MODE_STEPPEDAttributes
REMARKSSTD_CLAUSESTD_REFDESCGuided light transmitter
TLX_S01326_GUIDED_LIGHT_TRANSMITTERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCGuided light receiver
TLX_S01327_GUIDED_LIGHT_RECEIVERAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCGuided light TX, coherent
TLX_S01328_GUIDED_LIGHT_TX_COHERENTAttributes
TAGFUNCTIONPART_NOMANUFACTURERREMARKSSTD_CLAUSESTD_REFDESCDirectional coupler, optical
TLX_S01340_DIRECTIONAL_COUPLER_OPTICALAttributes
REMARKSSTD_CLAUSESTD_REFDESC
Copyright CADXChange. Use and modify the symbols freely in your own drawings and projects, including commercial ones; credit and a link are needed only when you publish them. Please do not redistribute or resell the library. Each ZIP holds one plain DWG file in AutoCAD 2018 format and a README; no add-in needed. Provided as is, without warranty. Library terms (CXL-1.0)
IEC 60617 has several parts. The other libraries of the standard:
- Common electrical symbols (IEC 60617)
- Power system single-line symbols (IEC 60617)
- Power system primary equipment symbols (IEC 60617)
- Power system secondary equipment symbols (IEC 60617)
- Electron tubes, crystals, delay lines (IEC 60617)
- Logic gate symbols (IEC 60617)
- Flip-flops, multiplexers, op amps (IEC 60617)
- Telephone, selectors, sound and recording (IEC 60617)
- Relays, protection and switching devices (IEC 60617)
- Machines, transformers, meters and symbol elements (IEC 60617)
- Busbar trunking, cable television, airfield lighting and connectors (IEC 60617)
- Gas-insulated switchgear, alarms and installation devices (IEC 60617)
Related symbol libraries
Missing a symbol? Tell us which one.
Attributes for parts lists
The devices (amplifiers, filters, attenuators, generators, converters, lasers, transmitters, receivers) carry a visible reference such as A1, FL1, AT1, G1 or TX1 and invisible attributes: FUNCTION, PART_NO, MANUFACTURER and REMARKS. Small marks (polarization, frequency lines, pulse shapes) have a remarks field only, so they can be combined freely.
How to use the library
- Unzip the file and open the DWG. Copy the symbols you need into your plan, or drag the blocks in from DesignCenter (ADCENTER).
- The symbols are drawn at plotted size in millimetres, on a 3 mm grid: a boxed filter or amplifier is about 12 mm wide, an antenna about 20 mm high. Insert them at the scale of your drawing, for example scale 2 on a 1:2 drawing.
- Line-type symbols (antennas, waveguide parts, couplers) have the insertion point at the connection, so they snap onto a conductor. Boxed devices are centred on the box, with the connection stubs at the left and right edge. Marks are centred on their own figure.
- The filters share one box and differ only by the curve inside (low-pass, high-pass, band-pass, band-stop), and the converters share one box with a diagonal. Edit the inner mark to make a variant that is not in the library.
About IEC 60617-10
IEC 60617 is the international standard for graphical symbols for diagrams. Part 10 covers telecommunications: transmission, from antennas and waveguides to modulation, filters, amplifiers and optical fibre. This library follows the figures of that part.
These symbols are our own drawings after the figures of the standard. They are not copied from it, and the library is not certified against it. Check them against the standard, your company standard or your customer’s legend before you decide to use a symbol.
What changed in each version
Version 1.1 · October 21, 2026
New symbols (14)
Frequency band, general · Frequency band, mastergroup · Erect band, several channels · Erect band, channel group · Band of mixed channels · Amplitude-modulated carrier · Phase modulated carrier · AM carrier, guard gaps · AM carrier, marked centre · SSB, suppressed carrier · Reduced-carrier, erect SSB · Suppr. carrier, scrambled · AM carrier, vestigial band · Band of five channels
Frequently asked questions
- How do I draw a filter?
- Use the block of the type you need: “Low-pass filter”, “High-pass filter”, “Band-pass filter” or “Band-stop filter”. The box, the two connections and the curve are drawn, and the reference FL1 is ready to number.
- Where are telephone sets and selectors?
- They belong to switching and peripheral equipment, part 9 of the standard, and are in the library “Telephone, selectors, sound and recording (IEC 60617)”. This one holds the transmission symbols.
- Can I use the symbols in commercial projects?
- Yes. They are free to use and modify in your own projects, including commercial ones. They are provided as is, without warranty. Please do not redistribute or resell the library; see the library terms.
- Why do the marks have no reference?
- Polarization, frequency lines and pulse shapes are not devices; they are marks that go next to or inside another symbol. They only have a remarks field, so you can combine them without extra attributes in the drawing.
- Can I change a symbol or add attributes?
- Yes. Open the DWG, edit a block with BEDIT to change it or add attributes, and save. To update drawings that already contain the block, run ATTSYNC or replace the block. Make a backup first: attribute values can be lost if ATTSYNC is used carelessly.
- Where do I find a ready-made set of these symbols for AutoCAD?
- AutoCAD itself ships only a small set of sample blocks, so a full symbol set has to come from a library. Download the ZIP on this page and open the DWG: every symbol is a block. Insert one with INSERT (Blocks palette, Libraries tab, then pick the DWG) or drag it from DesignCenter (ADCENTER). You can also download a single symbol on its own.