Pump head and power calculator

Find the head a pump must deliver, the power it needs on the shaft and the motor to fit.

Result

Total head
25.0 m
Shaft power
4.86 kW
Motor size (standard)
7.50 kW
Hydraulic power
3.399 kW
Electrical input power
5.28 kW
Differential pressure
2.45 bar
Specific energy
0.106 kWh/m³

Check the duty point against the pump's own curve, and the NPSH available against the NPSH required.

Working

  1. HH(1)H=Δz+hf+p2−p1ρg=15.00+10.00+0.00=25.00 m\begin{aligned}H &= \Delta z + h_{\mathrm{f}} + \frac{p_{2} - p_{1}}{\rho g} \\ &= 15{.}00 + 10{.}00 + 0{.}00 \\ &= 25{.}00\,\mathrm{m}\end{aligned}
  2. PhP_{\mathrm{h}}(2)Ph=ρgQH=998.2×9.807×0.013889×25.00=3.399 kW\begin{aligned}P_{\mathrm{h}} &= \rho gQH \\ &= 998{.}2 \times 9.807 \times 0{.}013889 \times 25{.}00 \\ &= 3{.}399\,\mathrm{kW}\end{aligned}
  3. PsP_{\mathrm{s}}(3)Pshaft=Phηp=3.3990.70=4.856 kW\begin{aligned}P_{\mathrm{shaft}} &= \frac{P_{\mathrm{h}}}{\eta _{\mathrm{p}}} \\ &= \frac{3{.}399}{0{.}70} \\ &= 4{.}856\,\mathrm{kW}\end{aligned}
  4. PmP_{\mathrm{m}}(4)Pmotor≥Pshaft×SF=4.856×1.15=5.584 kWP_{\mathrm{motor}} \ge P_{\mathrm{shaft}} \times \mathrm{SF} = 4{.}856 \times 1{.}15 = 5{.}584\,\mathrm{kW}

Based on: P = ρ g Q H / η; IEC 60072 (motor ratings)

How it is calculated

Total head H = Δz + h_f + (p₂ − p₁)/(ρg): the static lift, the friction head of the pipe and fittings, and the difference between the discharge and suction vessel pressures.

Hydraulic power P_h = ρ g Q H. Shaft power P = P_h / η_pump. The motor is the next standard size at or above P × service factor, and the electrical input is P / η_motor.

Take the pump efficiency from the pump curve at the duty point. The motor list follows common IEC ratings.

Questions

How do I calculate pump power?
Power in kW = ρ × 9.81 × Q (m³/s) × H (m) / 1000 / efficiency. Enter the flow, the head and the efficiencies and the calculator does it, then picks a motor.
How do I get the head?
Add the height to lift, the pipe and fitting loss (from the pressure-drop calculator) and the pressure difference between the two vessels expressed as head.
Why add a service factor?
It leaves room on the motor for a flow above the duty point or a thicker fluid. 1.15 is often specified.
What about NPSH?
Not included here. Check that the NPSH available at the pump inlet exceeds the NPSH required by the pump curve with a margin, to avoid cavitation.