PV string size calculator

Find how many modules can go in series so the string stays inside the inverter's voltage window on the coldest and hottest day.

Result

Fewest modules in series
6
Most modules in series
20
Highest string voltage at the lowest temperature
1,080 V
Lowest string MPP voltage at the highest temperature
220 V
Strings in parallel per input
1
Modules for the array
184
Strings at the largest length
9
DC to AC ratio
1.25

Use the module's own coefficient and the site's record low. A string made longer than the maximum can destroy the inverter on a cold morning.

Working

  1. Voc,coldV_{\mathrm{oc,cold}}(1)Voc,min=Voc×(1+β×(Tmin−25))=49.5×(1+(−0.00260)×(−10−25))=54.00 V\begin{aligned}V_{\mathrm{oc,min}} &= V_{\mathrm{oc}} \times \left(1 + \beta \times \left(T_{\mathrm{min}} - 25\right)\right) \\ &= 49{.}5 \times \left(1 + \left(-0{.}00260\right) \times \left(-10 - 25\right)\right) \\ &= 54{.}00\,\mathrm{V}\end{aligned}
  2. Vmp,hotV_{\mathrm{mp,hot}}(2)Vmp,hot=Vmp×(1+β×(Tcell−25))=36.64 V\begin{aligned}V_{\mathrm{mp,hot}} &= V_{\mathrm{mp}} \times \left(1 + \beta \times \left(T_{\mathrm{cell}} - 25\right)\right) \\ &= 36{.}64\,\mathrm{V}\end{aligned}
  3. NmaxN_{\mathrm{max}}(3)Nmax=min⁡(⌊Vdc,maxVoc,cold⌋,  ⌊Vmppt,maxVmp,cold⌋)=min⁡(⌊110054.00⌋,  ⌊100045.28⌋)=20\begin{aligned}N_{\mathrm{max}} &= \min \left(\lfloor \frac{V_{\mathrm{dc,max}}}{V_{\mathrm{oc,cold}}}\rfloor ,\; \lfloor \frac{V_{\mathrm{mppt,max}}}{V_{\mathrm{mp,cold}}}\rfloor \right) \\ &= \min \left(\lfloor \frac{1100}{54{.}00}\rfloor ,\; \lfloor \frac{1000}{45{.}28}\rfloor \right) \\ &= 20\end{aligned}
  4. NminN_{\mathrm{min}}(4)Nmin=⌈Vmppt,minVmp,hot⌉=⌈20036.64⌉=6\begin{aligned}N_{\mathrm{min}} &= \lceil \frac{V_{\mathrm{mppt,min}}}{V_{\mathrm{mp,hot}}}\rceil \\ &= \lceil \frac{200}{36{.}64}\rceil \\ &= 6\end{aligned}

Based on: IEC 62548; IEC 61215 (temperature coefficients)

How it is calculated

Voltage rises in the cold: V_oc,cold = V_oc × (1 + β × (T_min − 25)), with β the (negative) temperature coefficient. The most modules in series is the smaller of ⌊V_dc,max / V_oc,cold⌋ and ⌊V_mppt,max / V_mp,cold⌋.

Voltage falls in the heat: V_mp,hot = V_mp × (1 + β × (T_cell − 25)). The fewest modules is ⌈V_mppt,min / V_mp,hot⌉, so the string stays above the MPPT window floor.

Strings in parallel per input follow from the inverter's current limit and the module's I_sc. Based on IEC 62548; also check the module's maximum system voltage and the local code for the 1.25 factor on current.

Questions

Why use the lowest temperature for the maximum string?
Open-circuit voltage is highest on a cold, sunny morning. If the string exceeds the inverter's maximum DC voltage then, it can be damaged.
How do I know the cell temperature?
Ambient plus about 30 °C at full sun for a roof or ground mount; use the NOCT or the data sheet value if you have a better figure.
What DC/AC ratio is normal?
1.1 to 1.3 is common. A higher ratio makes better use of the inverter but clips power at noon in summer.
Where does the temperature coefficient come from?
The module data sheet, usually about −0.25 to −0.30 %/°C for the open-circuit voltage of silicon modules.