How it is calculated
Voltage rises in the cold: V_oc,cold = V_oc × (1 + β × (T_min − 25)), with β the (negative) temperature coefficient. The most modules in series is the smaller of ⌊V_dc,max / V_oc,cold⌋ and ⌊V_mppt,max / V_mp,cold⌋.
Voltage falls in the heat: V_mp,hot = V_mp × (1 + β × (T_cell − 25)). The fewest modules is ⌈V_mppt,min / V_mp,hot⌉, so the string stays above the MPPT window floor.
Strings in parallel per input follow from the inverter's current limit and the module's I_sc. Based on IEC 62548; also check the module's maximum system voltage and the local code for the 1.25 factor on current.
Questions
- Why use the lowest temperature for the maximum string?
- Open-circuit voltage is highest on a cold, sunny morning. If the string exceeds the inverter's maximum DC voltage then, it can be damaged.
- How do I know the cell temperature?
- Ambient plus about 30 °C at full sun for a roof or ground mount; use the NOCT or the data sheet value if you have a better figure.
- What DC/AC ratio is normal?
- 1.1 to 1.3 is common. A higher ratio makes better use of the inverter but clips power at noon in summer.
- Where does the temperature coefficient come from?
- The module data sheet, usually about −0.25 to −0.30 %/°C for the open-circuit voltage of silicon modules.
Other calculators
- kW to amps calculator
- Voltage drop calculator
- Cable size calculator
- Transformer size calculator
- Low-voltage short-circuit calculator
- High-voltage short-circuit calculator
- Earth resistance calculator
- Lightning rod height calculator
- Power factor correction calculator
- Generator size calculator
- Lighting calculator
- Battery capacity calculator
- Pipe insulation thickness calculator
- Pipe flow and diameter calculator
- Pipe pressure drop calculator
- Pump power calculator
- Heat exchanger calculator